00403A Cover_SSC-17TQ 10/9/03 11:31 AM Page 1 COLOR DUAL QUAD OBSERVATION SYSTEM SSC-17TQ INSTALLATION MANUAL POWER
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN e-2 CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-4 Contents IMPORTANT SAFEGUARDS...................................................e-2 Chapter 3: Setting each item function at SETUP MENU 3-1) CLOCK/DISPLAY SET MENU function setting .............e-30 e-4 3-2) CHANNEL TITLE MENU function setting .....................e-31 3-3) SYSTEM SET MENU function setting ............................e-32 Chapter 1: System Components and Installation 1-1) Environmental requirements for installation and safety ....
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-6 Chapter 1: System Components and Installation 1-2) System Components The system consists of the following: 1-1) Environmental requirements for installation and safety e-6 e-7 This section describes the environmental requirements for safe installation and use. Install the product on a flat table or in a rack. It should be used only when level and should not be used when stood vertically or obliquely.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-8 ITEM MODEL DESCRIPTION Q’ty NOTE LCD MONITOR SMT-170 17" TFT-LCD MONITOR 1 - DIGITAL DUAL QUAD SOQ-080N DIGITAL DUAL COLOR 1 - STANDARD CAMERA SOD14C NORMAL TYPE CAMERA 2 - PIR CAMERA SMM- PIR CAMERA 1 Tapping Screw 4 STANDARD TYPE 2 1-3) CAMERA composition and installation method 1) Standard Camera composition (SOD14C) QUAD SWITCHER e-8 e-9 PIRCAM CAMERA BRACKET SBR-110 (HUD 5=2, BH M3 x 30=2) CAMERA BRACKET Tapping Screw 6
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-10 f. Speaker 3) PIR Camera composition It outputs the sound signal which was transfered from the monitor. e-10 • PIN configuration of the PIR CAMERA is the same as the STANDARD e-11 CAMERA. • But, PIR CAMERA does not provide ALARM JACK. 3 2) INSTALLING STANDARD CAMERA (SOD14C) SOD14C s camera can be attached to the wall, ceiling or shelf using the camera mount bracket (SBR-110).
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-12 ➃ 6-pin modular jack Used to connect the camera to the monitor. 1> Vertical Detection Line e-12 PIN NUMBER e-13 SPEC ! SPEAKER(HOT) @ VIDEO_OUT # GND $ SPEAKER(COLD) % AUDIO_OUT/ALARM_OUT ^ 12V DC • Please consider the horizontal detection area and the vertical detection line when choosing an installation site.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-14 Camera installation Hints 1. Do not install directly towards rising or setting sun. Can cause burn or damage to internal options. 2. Do not limit desired detection zone by interference of curtains, screens, potted plants, etc. 6 e-14 8 3. Also, do not locate it in front of source of water/oil vapors. Avoid placement of heat source inside detection zone 7 4. Do not install outdoors.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-16 4) INSTALLING THE PIR CAMERA (SMM-PIRCAM) 1. Choose an installation site that can sufficiently support 5 times the weight of the equipments to be 4. Connect the Camera connector(RJ-11) cable to the case-rear as well as the cable to be connected to the terminal. installed. e-16 2. Remove the screw (BH M2.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-18 6. Adjust the direction of the lens. 4) CAMERA MOUNT BRACKET(SBR-110) & STANDARD CAMERA(SOD14C) 1) Use the cross (+) screw driver to turn the screw (indicated by the arrow in the illustration) (1) Overview counterclockwise slightly. The lens body will move. e-18 2) Tilt the lens body down about 10° from the horizontal, and then turn the screw clockwise to fasten CAMERA MOUNT BRACKET (SBR-110) is used to attach the camera to a wall, ceiling or shelf.
00403A SSC-17TQ_ENG • 10/9/03 11:30 AM Page e-20 Loosen the handle by turning it in a counterclockwise direction and then adjust the camera 1-4) CAMERA Composition and Connecting Method to SYSTEM position . Tighten the handle, turning it clockwise, and lock the camera in position. After positioning monitor and installing three cameras to a desired location, please connect CAMERA e-20 • Connect the camera cable to the camera.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-22 1-5) External terminal connecting method for CAMERA and SYSTEM f) Connect the A/O (HOT) terminal on the rear panel to the Alarm IN terminal of the VCR. g) Connect the A/O (COLD) terminal on the rear panel to the Ground terminal of the VCR. h) Connect the A/R terminal on the rear panel to the Alarm Reset terminal of the VCR.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-24 1-7) REAR Panel function 1-8) Mounting the DIGITAL DUAL QUAD (SOQ-080N) ACCESSORY e-24 e-25 Screws (BH M3X6, 4EA) Screws (TH M4X20, 4EA) Rack Mount Adapters (2EA) a. CAMERA IN (RJ-11) Video camera input terminals. You Can connect up to 8 Cameras with RJ-11 connectors. b. CAMERA OUT (BNC) Video Camera out terminals. c. VCR • Connects to the VCR using a 6-Pin connector.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-26 Chapter 2: REMOTE CONTROL Function and Using Method 2-4) SET- KEY Alarm function and loss function can be cancelled while the alarm or loss is working. e-26 The Remote Controller(REMOCON) is contained in the 17" TFT-LCD Monitor (SMT-170). 2-1) TALK KEY e-27 2-5) QUAD/PAGE- KEY Allows users to display QUAD A or QUAD B at QUAD DISPLAY MODE.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-28 2-7) PIP- KEY e-28 2-12) ENTER- KEY Can be used to see the main screen while Single screen is displayed. The main screen can be changed As a multi functional ENTER key, it is used for 1. entering from the menu into the submenu, 2. moving and transfered to another channel while PIP is working. Please refer to "CHAPTER 4. DISPLAY into the full screen of selected channel. e-29 MODE SETTING" for PIP function and details.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-30 Chapter 3: Setting each item function at SETUP MENU e-30 Pressing the MENU BUTTON of the FRONT PANEL allows users to enter SETUP MENU and see the following menu OSD box. Setting method of each SETUP MENU function and operation is as follows. [SETUP MENU] 1. 2. 3. 4. 5. CLOCK/DISPLAY SET CHANNEL TITLE SYSTEM SET EVENT SET EVENT LIST DATE TYPE: MM/DD/YY ↔ YY/MM/DD ↔ DD/MM/YY.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-32 3-3) SYSTEM SET MENU function setting PIP POSITION: BOTTOM-RIGHT ↔ TOP-LEFT ↔ TOP-RIGHT ↔ BOTTOM-LEFT. • Select the PIP position among the four options listed above. You may change DWELL TIME, PIP POSITION, BORDER COLOR, LOSS CHANNEL COLOR, SYSTEM ID. e-32 If you click the UP/DOWN button to select 3. SYSTEM SET in the SETUP MENU and click the ENTER button, the following screen will be displayed. [SYSTEM SET] DWELL TIME...
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-34 3-4) EVENT SET MENU function setting EVENT DETECT... You may change EVENT HOLD TIME, EVENT BUZZER, EVENT DETECT. If you click the UP/DOWN button to select 4. EVENT SET in the SETUP MENU and click the e-34 • [EVENT SET] EVENT HOLD TIME EVENT BUZZER EVENT DETECT... - Select “EVENT DETECT...” with the UP/DOWN button and click the ENTER button. e-35 Then the following screen pops up. ENTER button, the following screen will be displayed.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-36 3-5) EVENT LIST MENU function setting Chapter 4: DISPLAY MODE setting method You can check the ALARM/LOSS EVENT LIST. If you click the UP/DOWN button to select 5. EVENT LIST in the SETUP MENU and click the ENTER button, the following screen will be e-36 displayed. 4-1) SINGLE SCREEN DISPLAY e-37 The initial display mode is QUAD A mode.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-38 4-2) QUAD MODE DISPLAY Users can switch SINGLE DISPLAY MODE and SEQUENTIAL DISPLAY MODE to QUAD Pressing on the SEQUENCE KEY on the front allows screen to automatically switch to SINGLE DISPLAY MODE, or QUAD A (QUAD B) to QUAD B (QUAD A), or PIP MODE to QUAD MODE, MODE full screen or QUAD MODE. (‘no-signal’ channels will be skipped while single screen is press the QUAD/PAGE KEY. auto-switching.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-40 4-4) PIP MODE DISPLAY This is available in Single Screen mode. While in a single screen display, press the ZOOM key to display the zoom area. When in a PIP screen, you can use the UP and DOWN buttons to change the main channel and use the Use the LEFT, RIGHT, UP, and DOWN keys to move to the area you want to zoom in, and then press ENTER key to switch between the main and sub screens. In addition, you can change the location of the the ENTER key.
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-42 Chapter 5: Each product feature e-42 SOD14C : Standard Camera SMM-PIRCAM : PIR Camera Model Name SMM-PIRCAM Broadcasting System NTSC STANDARD 1/4'' SUPER HAD IT CCD Model Name SOD14C Imaging Device Broadcasting System NTSC STANDARD Effective Pixels 510(H) x 492(V) Imaging Device 1/4 ”SUPER HAD IT CCD Synchronization Internal Effective Pixels S 510(H) x 492(V) Resolution 330 TV Lines(H), 350 TV Lines(V) Synchronization Internal Signal O
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-44 Memo SOQ-080N : DIGITAL DUAL QUAD Video Input • CAMERA 8 Input: 1.0Vp-p(CVBS), 75Ω • VCR 1 Input (to Video Out of VCR) : 1.0Vp-p, 75Ω e-44 Video Output • BNC 8 Output: 1.0 Vp-p, 75Ω, S-Jack Type, CVBS • VCR 1 Output: 1.
00403A SSC-17TQ_ENG Memo 10/9/03 11:30 AM Page e-46
00403A Cover_SSC-17TQ Samsung CCTV dba GV1 1621 West Crosby, Suite 104 Carrollton, TX. 75006 PHONE : 866.492.8246 10/9/03 11:31 AM Page 2 Part No.: AB68-00403A (Rev.