SSA-P400 SSA-P400T SSA-P401 SSA-P401T Access Control Panel user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
5. Keep out of direct sunlight and heat radiation sources. It may cause fire. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.
contents 5 7 12 Features What’s included Cable Selection 13 13 14 15 18 Connecting the termination resistor and diode Earth-grounding the communication cables Power, Reader, and I/O Connection Communication Line Connection INITIALIZATION 22 23 System Initialization Board ID Setting 24 Troubleshooting 26 Product Specifications PRODUCT INTRODUCTION 5 INSTALLATION AND EXTERNAL CONNECTION 22 TROUBLESHOOTING 24 PRODUCT SPECIFICATIONS 26 4_ contents
product introduction FEATURES State-of-the-art Access Controller Standalone Operation By connecting to 4 card readers, you can use this product to control the access of the maximum of 4 doors. This controller determines to allow access by reading data from the card reader, and controls the open/close of the door relay and enables you to change other output settings. Upon receipt of an incoming external input signal (sensor or Exit button), it launches an output device such as the relay.
product introduction Input Port Format Setup 15 input ports are provided by default. For these ports, you can specify if the format of the incoming signal is blocked (NO) or connected (NC) in normal operation. This setting will make all ports operate same regardless of the output status of the input device. Time Scheduling You can specify a time range during which a specific operation is performed. You can specify a specific time range for a schedule code, which will be transferred to the applicable device.
WHAT’S INCLUDED Check if the following items are included in the product package.
product introduction Main Board 1 2 3 24 25 4 23 22 16 5 21 17 6 20 15 7 19 10 8 18 9 14 13 12 11 The address number specified by the address setup switch should match that of the host computer as it is used for communications with the host computer. 1 Board ID Setup Switch 2 I/O Board Connection Communication ports to connect to the I/O board, which include Input #8 through Input Port #15 and Output #8 through Output #15.
RJ-45 Connect the LAN cable for TCP/IP communications. 7 RS-232 Communication Port One RS-232 communication port is provided. Used to exclusively connect to a PC in a local area. 8 RS-422 Communication Port 9 Power Connection Port 10 LED Extension Port Port used to extend the power and communication indicators so that they can display in an external device. 11 TCP/IP Module LED Indicator For TCP/IP module communications, the status of the TCP/IP module will be provided additionally.
product introduction I/O Board 1 2 19 3 20 4 18 5 17 6 16 7 15 8 14 21 13 12 9 10 11 1 Fixing Hole Used to fix the main board to the I/O board using screws. 2 Power LED Indicator The red indicator turns on in the normal power supply condition. 3 Main Board Connection Port Connector used to connect to the main board. 4 Output (Relay #5) Port Output port #5. 5 Output (Relay #6) Port Output port #6 (FORM-C). 6 Output (Relay #7) Port Output port #7 (FORM-C).
INPUT #8 Input port #8. 9 INPUT #9 Input port #9. 10 INPUT #10 Input port #10. 11 INPUT #11 Input port #11. 12 INPUT #12 Input port #12. 13 INPUT #13 Input port #13. 14 INPUT #14 Input port #14. 15 INPUT #15 Input port #15. 16 Output (Relay #9) Port Output port #9 (FORM-C). 17 Output (Relay #10) Port Output port #10 (FORM-C). 18 Output (Relay #11) Port Output port #11 (FORM-C). 19 Output (Relay #12) Port Output port #12 (FORM-C).
product introduction CABLE SELECTION RS-232 RS-422/RS-232 Converter HOST P.C.
installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor Note that termination resistors of lower than 90 are not allowed, neither more than one termination resistor is accepted for the communications system.
installation and external connection EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable. However, the earth-grounding of the communication cable is not easy at all, and it also causes an increased installation cost. There are three grounding points available for installation: 1. Earth Ground 2. Chassis Ground 3.
POWER, READER, AND I/O CONNECTION Power Connection INSTALLATION AND EXTERNAL CONNECTION DC +12V GND - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the GND (-) line of DC 12V to the GND (-) port. Reader Connection Reader #4 Reader #1 Reader #3 Reader #2 GND D1 D0 DC+12V - Connect the plus (+) line of the reader to the corresponding port (DC +12V). - Connect the minus (-) line of the reader to the GND (-) port.
installation and external connection Input Connection GND Input #7 GND Input #6 GND Input #5 GND Input #4 GND Input #3 GND Input #2 GND Input #1 Door Open Sensor PUSH Exit Button Door Open Sensor PUSH Exit Button - Exit Button Connection (Input #1, Input #3) 1. Connect one line of the Exit button to an input port (Door 1: Input #1, Door 2: Input #3) of the Exit button. 2. Connect the other line of the Exit button to GND (-). - Door Sensor Connection (Input #2, Input #4) 1.
Output Connection DC +12V GND INSTALLATION AND EXTERNAL CONNECTION Door Lock NC COM POWER FAIL SAFE COM NO Alarm Device GND POWER FAIL SECURE - If the door lock is in POWER FAIL SAFE mode: (Door 1: Relay #1, Door 2: Relay #3) 1. Connect the COM line of the Door Lock relay to DC +12V. 2. Connect the plus (+) line of the Door Lock to the Normal Close (NC) line of the Door Lock relay. 3. Connect the minus (-) line of the Door Lock to GND (-).
installation and external connection COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: HOST PC RS-232 2 3 5 9-Pin Female Connector 1. Connect RS-232 TX to pin #2 of the 9-pin connector. 2. Connect RS-232 RX to pin #3 of the 9-pin connector. 3. Connect RS-232 GND to pin #5 of the 9-pin connector. 4.
RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: INSTALLATION AND EXTERNAL CONNECTION RS-422/232 Converter RxD TxD Power RS-232C HOST T+ T- R+ R- MAX. 1200m TXTX+ RXRX+ 1. Connect RS-422 TX(-) to the RX(-) port of the converter. 2. Connect RS-422 TX(+) to the RX(+) port of the converter. 3. Connect RS-422 RX(-) to the TX(-) port of the converter. 4.
installation and external connection RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications. RS-422/232 Converter RxD TxD Power RS-232C HOST T+ T- R+ R- MAX. 1200m TXTX+ RXRX+ - Follow the guidelines below to make connection between devices. 1. Connect TX(-) of one device to TX(-) of other one. 2. Connect TX(+) of one device to TX(+) of other one. 3. Connect RX(-) of one device to RX(-) of other one. 4.
TCP/IP Communication Port Connection 1) TCP/IP Communication Configuration HUB PC INSTALLATION AND EXTERNAL CONNECTION TCP / IP TCP / IP 2) TCP/IP Connection Connect the LAN cable to the TCP/IP RJ-45 jack as shown. (applicable only to SSA-P400T / SSA-P401T) 1. Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the network system. 2. Set a unique communication address (COMM ADDR) for each unit 3. Install and launch the application (SAMS).
initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. 1. Locate the Initialize switch ( switches simultaneously. ) on the upper right corner and press both Initialize Switch • Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep. Releasing both switches will stop the beep, and restarts the system after the initialization.
BOARD ID SETTING 0/ Each device in the multi-serial communication connection is assigned a unique number to identify each other. 1. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. ,4% ) • You can specify between 0 and 255 for the board ID. ❖ Refer to the example below for the board ID.
troubleshooting TROUBLESHOOTING If the product does not work properly, please check the followings before contacting us. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Action Can I specify RF only or RF+P/W mode differently according to the card? 1) 2) It is not available. The mode is defined for each reader device, not the card. Thus, you can not specify the mode for each card differently.
Problem No communication is available when the system is in sync with the PC. Action 1) Check the communication settings between the PC application and the device. - Check the board ID (COMM address) and match it with that of the PC application. - Specify a unique board ID (COMM address) for each of the multiple devices. - Check the baud rate if it matches with the PC application. - If you initialize the device, it will be defaulted to 9,600bps.
product specifications PRODUCT SPECIFICATIONS Item SSA-P400 SSA-P400T SSA-P401 Users 1,000 ~ 20,000 / 30,000 / 40,000 / 50,000 Users (Default :20,000) Event Buffer 20,000 ~ 29,500 / 3,000 / 8,000 / 14,000 (Default : 29,500) DC 12V, MAX. 380mA Power / Current DC 12V, MAX.430mA Reader Port 4ea: 26bit Wiegand, 4 / 8bit Burst for PIN Door Open Time 00~99 Sec. (Default 3Sec.) Communication RS232 / RS422 / RS485 Baud Rate(bps) 9,600bps Input Port 15ea RS232 / RS422 / RS485, TCP/IP DC 12V, MAX.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.