Specifications

SRP-500 Command Manual
Rev. 1.00 BIXOLON
- 24 -
<Function 11>BS ^ E pL pH fn a d1….dk (fn=11)
Code:
ASCII
BS ^ E pL pH fn [d11...d16][d12][d13][d14]
Hex
08 5E 45 pL pH 0B [d11...d16][d12][d13][d14]
Decimal
8 94 69 pL pH 11 [d11...d16][d12][d13][d14]
Range:
8 (pL + pH x 256) 10 (8 pL 10, 0 pH 255)
fn=11
48 d 57
Default:
Parity: no parity, Flow control: DTR/DSR, Data length: 8 bits
Description:
This command specifies the configuration items of the serial interface such as the baud rate, parity, flow control, data
length, collectively.
Setting Order Configuration item
1 Transmission speed
2 Parity
3 Flow control
4 Data length
The array of parameters change according to pL, pH as follows:
When (pL+pH x256) =10:
d11~d61: Baud rate value
d12: Parity setting value
d13: Flow control setting value
d14: Data length setting value
When (pL+pH x256) =9:
d11~d51: Baud rate value
d12: Parity setting value
d13: Flow control setting value
d14: Data length setting value