Specifications
SRP-500 Command Manual
Rev. 1.00 BIXOLON
- 23 -
<Function 6> BS ^ E pL pH fn a (fn=6)
Code:
ASCII
BS ^ E pL pH fn a
Hex
08 5E 45 02 00 06 a
Decimal
8 94 69 2 0 6 a
Range:
(pL + pH x 256) = 2 (pL = 2, pH = 0)
fn = 6
a = 3
(nL + nH x 256) = 5 (nL = 5, nH = 0)
Default:
None
Description:
The printer transmits to the host the setting value of the paper width.
[Data format to be sent]
Transmit data Hex Decimal Amount of Data
Header 37H 55 1 byte
Identifier 27H 39 1 byte
a(=3) 33H 51 1 byte
Separation code 1FH 31 1 byte
Paper width data 32H - 35H 50 - 53 1 byte
NUL 00H 0 1 byte
Remarks:
■ When the value of the paper width is set to 2 for accommodation of 57.5mm roll paper, the paper width data is
converted to ASCII character data, 0x32 and transmitted to the host.
■ The setting of the paper width can be changed by the control panel operation after entering “Memory Switch Setting
Mode”.
Differences:
None