Specifications

SRP-500 Command Manual
Rev. 1.00 BIXOLON
- 13 -
<Function 3> BS ^ E pL pH fn [b18...b11]...[ bk8...bk1] (fn=3)
Code:
ASCII
BS ^ E pL fn [b18...b11]... [bk8...bk1]
Hex
08 5E 45 pL fn [b18...b11]... [bk8...bk1]
Decimal
8 94 69 pL fn [b18...b11]... [bk8...bk1]
Range:
9 (pL + pH x 256) 65535
fn=3
b=48, 49, 50
1 k 10
Default:
It varies depending on the printer model
Description:
This command changes all the Memory Switch(Msw) 1 through 8 to the value specified by b simultaneously as
follows:
When b=48, 49, the corresponding bit is set to Off and On respectively.
When b=50, there is no change in the memory switch.
The setting items of the memory switch 1 are as follows:
Value
Msw
3 2 1
Function
48 48 48 Print density 130%
48 48 49 Print density 120%
48 49 48 Print density 110%
48 49 49 Print density 150%
49 48 48 Print density 100%
49 48 49 Print density 140%
49 49 48 Print density 90%
1-1~3
49 49 49 Print density 80%