<Function 2> BS ^ E pL pH fn d1 d2 d3 (fn=2)
Code:
ASCII
BS ^ E pL pH fn
Hex
08 5E 45 pL pH fn
Decimal
8 94 69 pL pH fn
Range:
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=2
Default:
None
Description:
This command terminates the user setting mode and performs a software reset.
Remarks:
This command activates setting items set in the user setting mode.
All the setting items will be effective only after performing this command.
After executing a software reset, the printer resumes the setting in effect at power on.