<Function 1> BS ^ E pL pH fn (fn=1)
Code:
ASCII
BS ^ E pL pH fn
Hex
08 5E 45 pL pH fn
Decimal
8 94 69 pL pH fn
Range:
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=1
Default:
None
Description:
This command starts the user setting mode, enabling the printer to notify that the mode has changed as follows:
[Mode change feedback]
Hexadecimal Decimal Number of Data
Header 37H 55 1 byte
Flag 20H 32 1 byte
NUL 00H 0 1 byte
Remarks:
■ This command is effective only in standard mode, not in page mode.
■ Upon entering the user mode setting mode by this command, the printer transmits “mode change feedback” to the
host.
■ The user setting mode should be enabled prior to processing <Function 2> through 12. Otherwise, those functions
are ignored.
■ After confirming “mode change feedback”, it is recommended to send the command to reconfigure the NV user
memory.
Differences:
None