Model : SR-S25/26NTA SR-S24/25/27FTA SR-S24/25/27DTA REFRIGERATOR CONTENT 1. Product Specifications 2. Safety Warnings 3. Specifications of Electric Components 4. Electric Circuit Diagram 5. External Size and Designations 6. Refrigeration Cycle and Cool Air Circulation 7. Function and Usage of Refrigerator 8. Circuit Operation Theory 9. Inverter Component List 10. Troubleshooting 11. Instruction of ICE-MAKER Operation and Troubleshooting 12. References 13. Disassembly Method of the Refrigerator 14.
1.
2. SAFETY WARNINGS Read all instructions before using this product and keep to the instructions in order to prevent danger or property damage. CAUTION/WARNING SYMBOLS DISPLAYED SYMBOLS Warning Caution means ÒProhibitionÓ. Indicates that a danger of death or serious injury exists. means ÒDo not disassembleÓ. means ÒNo contactÓ. means ÓThe things to be followedÓ. means ÒPower cord should be unplugged from the consentÓ means ÒEarth to prevent Electric shockÓ.
Caution Do not put bottles or kinds of glass in the freezer. Freezing of the contents may inflict a wound. Do not store narrow and lengthy bottles or foods in a small multi-purpose room. It may hurt you when refrigerator door is opened and closed resulting in falling stuff down. Do not store pharmaceutical products, scientific materials, etc., in the refrigerator. The products which temperature control shall not be stored in the refrigerator.
3. Specifications of Electric Components Items Specification Models SR-S25/26NTA, SR-S24/25/27FTA(DTA) Freezing Capacity (4 STAR) SK182P - L2W(127V/60Hz) SK182C - L2W(115V/60Hz) SK190Q - L2U(240V/50Hz) SK190H - L2U(220V/50,60Hz) Starting type C. S. R R.S.C.R Oil Charge SPLIT FIN TYPE Refrigerator SPLIT FIN TYPE Condenser Forced and natural convection type Dryer Molecular sieve XH-9 Capillary tube 0.75 3000, 5.
Specifications Items Model SR-S25/26NTA SR-S24/25/27FTA(DTA) Defrost-Heater(FRE) Conducting at F Defrosting 200 W 200 W Defrost-Heater(REF) Conducting at R Defrosting 90 W 90 W P-CORD Heater(FRE) Conducting at F Defrosting 30 W 30 W P-CORD Heater(REF) Conducting at R Defrosting 35 W 35 W DRAIN Heater(FRE) Conducting at F Defrosting 10 W 10 W Lamp Heater Interlock with R-FAN 2W 2W DISPENSER Heater Interlock with F-FAN - 5W HOME-BAR Heater Interlock with COMP - 10 W(FTA Only
4.
4-2) Basic Model (SR-S25/26NTA) 220V/50, 60HZ, 240V/50HZ REFERRENCE RED-RED BLU-BLUE ORG-ORANGE BRN-BROWN PNK-PINK GRY-GRAY WHT-WHITE YEL-YELLOW BLK-BLACK PRP-PURPLE W/BLKWHITE/BLACK S/BLUSKY BLUE 7
4-3) Model with Water Dispenser & Ice-Dispenser (SR-S24/25/27FTA) 115V~127V REFERRENCE RED-RED BLU-BLUE ORG-ORANGE BRN-BROWN PNK-PINK GRY-GRAY WHT-WHITE YEL-YELLOW BLK-BLACK PRP-PURPLE W/BLKWHITE/BLACK S/BLUSKY BLUE 8
4-4) Model with Water Dispenser & Ice-Dispenser (SR-S24/25/27FTA)220V~240V REFERRENCE RED-RED BLU-BLUE ORG-ORANGE BRN-BROWN PNK-PINK GRY-GRAY WHT-WHITE YEL-YELLOW BLK-BLACK PRP-PURPLE W/BLKWHITE/BLACK S/BLUSKY BLUE 9
5. External Size and Designations 5-1) External Size of Refrigerator (SR-S25/26NTA) 10 MODEL ÒAÓ ÒBÓ ÒCÓ ÒDÓ ÒEÓ ÒFÓ SR-S25NTA 791.5 193 874 791.5 792.8 797.5 SR-S26NTA 836.5 238 899 836.5 827.8 832.
5-2) External Size of Refrigerator [SR-S24/25/27FTA(DTA)] MODEL ÒAÓ ÒBÓ ÒCÓ ÒDÓ ÒEÓ ÒFÓ SR-S24F(D)TA 791.5 193 874 791.5 792.8 797.5 SR-S27F(D)TA 836.5 238 899 836.5 827.8 832.
5-3) Designation of Each Component (NTA) Freezer 1) Lamp-Fluorescent(FRE) 12 Refrigerator 9) Lamp-Fluorescent(REF) 2) Guard-FRE 10) Shelf-REF 3) Shelf-FRE 11) Tray-Utility 4) Tray-Ice 12) Case-VEG, A(Upp) 5) Case-Basket(Upp) 13) Guide-Bottle(REF) 6) Case-Basket(Low) 14) Case-VEG, B(Upp) 7) Cover-Tray Water 15) Case-VEG(Low) 8) Cover-Guard 16) Shelf-REF ASSÕY
5-4) Designation of Each Component (FTA) Freezer Refrigerator 1) Ice- Maker 9) Lamp-Fluorescent(REF) 2) Ice- Chute 10) Shelf-REF 3) Lamp-Fluorescent(FRE) 11) Tray-Utility 4) Shelf-FRE 12) Case-VEG, A(Upp) 5) Guard-FRE 13) Guide-Bottle(REF) 6) Case-Basket(Low) 14) Case-VEG, B(Upp) 7) Cover-Tray Water 15) Case-VEG(Low) 8) Cover-Guard 16) Shelf-REF ASSÕY 13
5-5) Designation of Each Component (DTA) Freezer 14 Refrigerator 1) Ice- Maker 9) Lamp-Fluorescent(REF) 2) Ice- Chute 10) Shelf-REF 3) Lamp-Fluorescent(FRE) 11) Tray-Utility 4) Shelf-FRE 12) Case-VEG, A(Upp) 5) Guard-FRE 13) Guide-Bottle(REF) 6) Case-Basket(Low) 14) Case-VEG, B(Upp) 7) Cover-Tray Water 15) Case-VEG(Low) 8) Cover-Guard 16) Shelf-REF ASSÕY
6.
6-2) Cool Air Circulation Frozen food compartment 15 16 Fresh food compartment
7. Function and Usage of Refrigerator 7-1. Panel Display Basic type (NTA) External type (FTA/DTA) 7-2. Temperature-Control function 1. Temperature-Setting Function of Freezer 1) At the first POWER ON, ÒMEDIUMÓ (3rd step) is automatically selected. 2) Select the temperature among five steps, WARMER, (WARMER-MEDIUM), (MEDIUM), (MEDIUM -COLDER), and COLDER by pushing one button.
Notice The specified temperature in the above table, from data when measured in unload state and at 1/3 H inside the room, is only to describe the temperature at each step generally. The actual temperature depends upon the surrounding conditions and the loading state. 7-3. Power-Freezing and Power-Refrigerating Set Power-Freezing and Power-Refrigerating by pushing the separate button.
7-4. ALARM function 1. Button TOUCH sound (ÒDING-DONGÓ sound) 1) If you push each button on the CONTROL PANEL, ÒDING-DONGÓ sounds to confirm the push. 2) If you push two buttons at one time or if you do other wrong-doings, ÒDING-DONGÓ does not sound. 2. DOOR-OPEN alarm (ÒDING-DONGÓ sound) 1) After two minutes with the door of the freezer or the refrigerator opened, alarm sounds ten times. 2) If the door is still in open in spite of the first ten-time alarm, alarm continues 10 times per minute.
7-6. TEST function TEST function is for quality control of PCB and the product, in-process control, and SVC. After check of the function of the product by the selection of TEST S/W, POWER should be turned ON again to perform self-diagnostic function. 1. Forced-Operation function 1) If you select button on MAIN PCB one time, COMP operates immediately without 5-minute DELAY. So, attention should be paid because if you perform Forced-operation at the COMP-OFF time, OVER LOAD may occur.
7-7. Self-Diagnosis Function 1. Self-Diagnosis Function on the first POWER-ON 1) On the first Power-on, lamps are ALL ON and self-diagnosis function operates internally. 2) If there is no fault on the self-diagnosis, DISPLAY will show the first normal state. 3) If there is any fault on the self-diagnosis, the relevant LED will flicker and alarm will sound. 4) ERROR (indicating fault) display by the self-diagnosis will continue till all the relevant problems is fixed or the self-diagnosis is canceled.
2. Self-Diagnosis function during the normal operation 1) If you push buttons for ÒPOWER-FREEZINGÓ and ÒPOWER-REFRIGERATINGÓ simultaneously for about 3 seconds during the normal operation, ALL ON/OFF in the temperature-setting DISPLAY will continue for about 2 seconds at 0.5-second interval. If you push buttons for ÒPOWER-FREEZINGÓ and ÒPOWER-REFRIGERATINGÓ simultaneously for about 5 seconds, including 2 seconds for LED ON/OFF, self-diagnosis function is selected.
No Item Relevant DISPLAY LED 7 Overload condition ÒPOWER-REFRIGERATIONÓ Meaning If the ambient temperature is above 35 Remark , relevant LED ON 8 WARMER-temperature 9 Freezer ÒCOLDERÓ condition (5th step) Normal condition No display LED among 3 MODE displays means If the ambient temperature is below 17 , relevant LED ON Normal operation state Ambient temperature is between 18 and 34 and normal freezing state normal MODE 7-9.
(1) At the moment of selection of stop function, ice-making function stops, but on eject, return to horizontality, and water-supply, stop state will be maintained after finish of water-supply. (2) When OFF function is selected, ice-making function stops. If you push button to select CRUSHED ICE or CUBE ICE, ICE-MAKER will continue to operate from the stop of ice-making. (This means that icemaking function does not operate from the first.
8. Circuit operation theory 8-1. Power supply part Voltage Circuit used BLK Vcc Power supply for MICOM BLK (DC 5V) and peripheral circuit BLU V12 Power supply to operate RELAY, (DC 12V) EJECT MOTOR, DISPLAY GRY RED BLU About AC 9V, pressed at 2nd side of LVT(LOW Volt Transformer), is suspended between CN10 ~ and DC 5V is made through constant-voltage IC (KA7805) rectified by Rectifier Diode.
8-4. DOOR S/W sensing circuit Terminal Voltage MICOM On DOOR CLOSE 5V (HIGH) F-room On DOOR OPEN 0V(LOW) On DOOR CLOSE 0V (LOW) R-room On DOOR OPEN 5V(HIGH) DOOR OPEN/CLOSE of F-room sensing is performed by connecting of CN30 to GROUND, supplying Vcc (DC 5V) to through resistance R404 (4.7 ) and supplying ÒLowÓ (0V) / ÓHighÓ(5V) to MICOM by DOOR OPEN/CLOSE of F-room. DOOR OPEN/CLOSE of R-room sensing is performed by connecting of CN31 to GROUND, supplying Vcc (DC 5V) to through resistance R403 (4.
8-6. KEY SCAN and DISPLAY circuit part REFERRENCE POWERFREEZING POWERREFRIGERATING POWER-FREEZING POWER-REFRIGERATING F, R ROOM DEODORIZATION Door-Securing ONor CRUSHED/CUBE POWER REF POWER FRE DOOR-SECURING or CUBE COLDER-HUMIDITYor CRUSH REFRIGERATOR ROOM SETTING' FREEZER ROOM SETTING Door-Securing OFF or LIGHT ON/OFF RED-RED BLU-BLUE ORG-ORANGE BRN-BROWN PNK-PINK GRY-GRAY WHT-WHITE YEL-YELLOW BLK-BLACK PRP-PURPLE W/BLKWHITE/BLACK S/BLUSKY BLUE 1.
8-7.
Like the above BLOCK DIAGRAM, LINE of AC 220V is connected to RELAY for COMP and COMMON for HEATER RELAY, respectively. At this time, if RELAY is not operated, contact point is NC state and RDefroster HEATER RELAY is OFF state. So, LOAD maintains OFF state. If COMP becomes the conditions for operation and COMP RELAY is operated (move to contact point NO), COMP becomes closed-circuit and operated and makes power for both ends of F, R-Defroster HEATER OFF state.
8-8.
Table of Temperature Change of Freezer ( : Relevant DIODE No. used) Temperature change Relevant DIODE No. used D604 D603 Temperature change D602 Temperature Limit + 0.5 - 0.5 + 1.0 - 1.0 + 1.5 - 1.5 + 2.0 - 2.0 + 2.5 - 2.5 + 3.0 - 3.0 + 3.5 - 3.5 + 4.0 Relevant DIODE No. used D604 D603 D602 D601 Table of Temperature Change of Refrigerator ( : Relevant DIODE No. used) Temperature change Relevant DIODE No. used D608 D607 D606 D605 Temperature change Temperature Limit + 0.
Change of NOTCH GAP of Freezer (ÒCOLDERÓ on the basis of ÒMEDIUMÓ) Change of NOTCH GAP of Freezer (ÒWARMERÓ on the basis of ÒMEDIUMÓ) Relevant DIODE No. used Relevant DIODE No. used GAP change GAP change D614 D616 D613 2.0 4.0 3.0 2.0 4.0 3.0 5.0 5.0 Change of NOTCH GAP of Refrigerator (ÒCOLDERÓ on the basis of ÒMEDIUMÓ) D615 Change of NOTCH GAP of Refrigerator (ÒWARMERÓ on the basis of ÒMEDIUMÓ) Relevant DIODE No. used Relevant DIODE No. used GAP change GAP change D618 D617 D620 4.
Temperature Change of Ice-Making SENSOR for Eject operation Classification -10 -11 -12 -13 -14 -9 -8 -7 D635 0 1 0 1 0 1 0 1 D636 0 0 1 1 0 0 1 1 D637 0 0 0 0 1 1 1 1 MODEL OPTION function This refrigerator can operate 2 MODEL using one MAIN PCB AssÕy.
8-10. PCB SUB AssÕy (INVERTER PCB) 1. EMI circuit COMMON MODE NOISE is attenuated by CHOKE LFI, NORMAL MODE NOISE and D.C RESISTANCE. 2. Rectifier circuit Holding voltage is converted to DC voltage by BRIDGE DIODE. It is ELECTROLYTIC CAPACITOR and composed of balance circuit 3. First starter circuit The current converted to DC by C2 is charged to C3 through R3.
5. Resonance output circuit To make the life-span of fluorescent light bulb longer, supply the filament pre-heat current. Line current is running through filament C6 RT1 filament C5 PT1. Resistance value is increased at PT1 by running of PTC pre-heat current. When impedance of PT1 is Higher than impedance of C7, the current runs toward C7 and so, discharge voltage is permitted to both ends of lamp. And finally, discharge occurs at lamp as a result of resonance of L and C. C5 PT1.
9. Inverter Component list NO Items Specification EA Remark 1 RESISTOR 2W 5% 150 kohm 1 R1 2 RESISTOR 1W 5% 120 ohm 1 R2 3 RESISTOR 1W 5% 560 kohm 2 R3, R4 4 RESISTOR 1/4W 5% 12 kohm 1 R5, R6 5 RESISTOR 1/4W 1% 2.35 ohm 2 R7, R8 6 RESISTOR 1/4W 5% 10 ohm 1 R9 7 RESISTOR 1/4W 5% 8.2 kohm 1 R10 8 ELECT CAPACITOR 450V 10 1 C2 9 ELECT CAPACITOR 6.3V 220 10 PE CAPCITOR 275VAC 0.
10. Troubleshooting Pre-Check 1. Before repair, check whether POWER CORD is normally connected. 2. Check using the following information.
Pre-Check 1. Compressor does not operate at the first power supply or after compressor is OFF. 2. During defrosting, compressor does not operate. 3. When Freezer sensor is not connected, low-temperature is sensed and so, compressor does not operate.
CRITERIA FOR JUDGEMENT 1. When normal refrigeration operation works on the first POWER ON, but troubles with freezing and refrigerating occur after some time (at defrosting step), there must be something wrong with Defrosting system and then, check the defrosting system on the basis of this trouble diagnosis.
A N After heating for some time, COMP ON comes to operate? If not, re-CHECK of the relevant sensor. Y Normal When the temperature of the defrost-sensor for F and R comes to be more than +5 and +17 , respectively, by heating, stop HEATING and return to COMP ON after pause time.
10-4) Trouble with self-diagnosis (1) Trouble with ambient thermal-sensor START N MAIN-PCB connector (CN32) is normally inserted? Y N Repair of connector contact trouble Ambient thermal-sensor port is normal? Y N Replacement of thermalsensor MICOM PIN#60 voltage input is normal? Check of MAIN-PCB cold lead and short Y No trouble with PCB and thermal-sensor. Re-check of connector contact trouble.
(3) Trouble with defrost-sensor for refrigerator (Bimetal) START N MAIN-PCB connector (CN31) is normally inserted? Repair of connector (CN31) contact trouble, Re-insertion Y N Defrost-sensor port is normal? Replacement of thermal-sensor Y Connection between Defrost-sensor and Connector is normal? N Repair of non-insertion of connector and contact trouble Y MICOM PIN#57 voltage input is normal? N Check of cold lead, short, lead Touch Y No trouble with PCB and thermal-sensor.
(5) Trouble with defrost-sensor for freezer(Bimetal) START MAIN-PCB connector (CN30) is normally inserted? N Repair of connector (CN30) contact trouble, Re-insertion Y Defrost-sensor port for freezer is normal? N Replacement of thermal-sensor Y Connection between defrost-sensor and connector is normal? N Repair of connector contact trouble, Re-insertion Y MICOM PIN#59 voltage input is normal? Y N Check of cold lead, short, lead Touch No trouble with PCB and thermal-sensor.
10-5) When alarm continues to sound, (1) When Ding-Dong sounds continuously, START Any trace of the permeation of water in DOOR S/W N Y Input voltage at MICOM Pin #48, #49 is changed? Replacement of DOOR S/W N (On DOOR OPEN/CLOSE) Repair of wire snapping and trouble with DOOR S/W Y MAIN-PCB connector (CN30, 31) is normally inserted? N Repair of connector contact trouble, Re-insertion Y N DOOR S/W itself is normal? Y Replacement of DOOR S/W No trouble with MAIN PCB and DOOR S/W Information 44
(2) When ÒPeepÓ continues to sound, START N Whether Forced-Defrost or Forced-Operation is selected? Cancellation of Forced-Defrost or Forced-Operation Y Buzzer sounds in spite of re-POWER ON? Y N MAIN-PCB is normal Check of Connector (CN40), lead TOUCH, insertion of particles, SHORT Information ÒPeepÓ alarm does not sound except the case of Forced-Operation, Forced-Defrost, and finding of abnormal things during Self-Diagnosis.
(4) When KEY selection of PANEL DISPLAY does not work, START N Insertion of Hinge-Upp PIN#11 of the Freezer is normal? Repair using the instruction in Reference No.
10-6) When FAN does not operate, (1) When FAN of the Freezer (F-FAN) does not operate (and COMP is operated normally by the temperature), START Y COMP is OFF? N Perform the Forced-Operation Open the DOOR of the Freezer N F-FAN is OFF? Check of sensor circuit related with F-DOOR S/W on PCB Y On push of F-DOOR S/W, FAN operates after delay? Determine and Repair on the basis of Reference No. 5) Check method of DOOR S/W Y N Power is supplied to FAN ends? F-FAN is normal Y N Refer to Reference No.
(2) When FAN of the Refrigerator (R-FAN) does not operate (and the temperature of the Refrigerator is sensed normally), START Y COMP is OFF? N Perform the Forced-Operation Open the DOOR of the Refrigerator Make the temperature of the Refrigerator increase N R-FAN is OFF? Check of sensor circuit related with R-DOOR S/W on PCB Y On push of R-DOOR S/W, FAN operates after delay? Determine and Repair on the basis of Reference No.
Caution Since about 300 V/DC converted from the inputted power to INVERTER PCB is supplied, replace when the power is OFF.
Caution 1. Since there is the possibility of electric shock while replacing the inside lamp of the Freezer, the power should be OFF to repair. 2. Be careful of burning because the glow lamp generates heat.
Pre-Check 1. Before repair, at first check whether the power of the consent is normal or whether the power cord is normally connected. 2. Handle with care since High Voltage is supplied to the inverter circuit and high voltage and high frequency are discharged.
10-10) When Cube and Crushed ice are not made properly, (When Cube ice is not made in spite of the selection of CUBE ICE,) START Y Cube Ice is made by the selection of CUBE ICE N F-Room Door is in open? If so, close the door.
10-11) When Light of Dispenser does not operate, START N LIGHT LAMP is normal? Y MICOM PORT #17 on MAIN PCB is HIGH (DC5V)? On the selection of light Replacement of LAMP N Check MICOM, Replacement of PCB Y IC03 PORT #12 is less than DC1V? N Check and Replacement of IC03 Y Contact of LIGHT RELAY RY74 is ON? Y N Replacement of RELAY RY74 Contact state of CONNECTOR CN72 on PCB other wire connection state, Contact trouble of Connector of Hinge-Upp of the Freezer, other things Information Lamp func
11. Instruction of ICE-MAKER operation and Troubleshooting 11-1) Instruction of ICE-MAKER operation START Operation to make horizontality of the ice tray on the first power-on or the return from the suspension of electric supply. Y Horizontality? N Eject Motor stop Reverse rotation of Eject motor Delay of 1 Cycle (below -10 ) Eject step On the finish of Ice-making, ice made in the tray is ejected while checking the signal change of the HOR/INV S/W and LEVER S/W and the changing time.
11-2) ICE-MAKER function(FTA/DTA) This is an instruction about the function of ICE-MAKER, which is optional. ICE-MAKER makes ice automatically and continually. The automatic ice maker makes and store ice in the ice storage bin. ICE-DISPENSER (FTA/DTA) is a model which dispenses ice made to the outside through the freezer compartment door. 1. First operation function 1) When Power is off and on again, there is no operation for 2 seconds.
3. Ice-making function Ice-making, which operates until the finish of ice-making in ICE-TRAY after water supply, issensed by the temperature sensed by Ice-Maker Sensor (may be changed by OPTION). 1) Check the temperature of Ice-Maker Sensor 90 minutes after water is supplied to Ice-Tray. 2) When -10 continues to be sensed by Ice-Maker Sensor for more than 5 minutes, ice-making is perceived to be finished. 4.
5. TEST function This is for the case of the Forced-Operation for the purpose of Operation TEST, A/S, and Cleaning and TEST function operates when TEST S/W implemented with the Ice-Maker itself is pushed for more than 1.5 second. 1) TEST function does not operate in the case of the Eject operation, Horizontality Noise, WaterSupply Operation, and Full Ice state. The function operates only in the case of horizontality and OFF of Lever S/W after cancellation of Full Ice.
11-3) ICE-MAKER CIRCUIT(On the model with Ice-Maker) RED BLK WHT WHT GRY REFERRENCE RED-RED BLU-BLUE GRY-GRAY WHT-WHITE BLK-BLACK VLT-VIOLET L/BLULIGHT BLUE BLU VLT L/BLU The above ICE-MAKER circuit is a circuit diagram of KIT in the Freezer. Operation of AC solenoid at Machine Room through RELAY and then, opening and closing of VALVE supplies water to the ICE-TRAY. This circuit is H/W for the function of Eject, Horizontality noise, Ice-Making Thermal-Sensing, and Full-Ice Sensing.
11-4) Troubleshooting of ICE-MAKER N DC power (5V,12V) is outputted normally? Power Terminal CHECK Power terminal trouble Replacement of MAIN PCB Y N Ice-Tray is in Horizontality? Disassembly of Connector as described in Reference No.
11-5) Designation of major components of Ice-Maker ICE-MAKER, KIT (EJECT-MOTOR) SUPT-RUBBER (EJECT-SENSOR) HOR-SWITCH (TRAY-ICE) LEVER-SWITCH SCREW TEST-SWITCH FIXER-SENSOR KNOB-TOUCH GUIDE-ICE COVER-SENSOR 11-6) Operation of Ice-Maker 1. Connect the water-supply line to the supplying valve of the refrigerator to supply water. (See the water tube connection procedure) 2. Push bucket to the end so that guide-ice of ice-maker is not in contact with the end of bucket.
11-7) Disassembly of Ice Maker 1. Pull out the bucket from the freezer. 2. Disassemble the SUPT-ICE MAKER, which fixes the ice-maker, and the wire housing in the rear of the maker. 3. Disassemble by lifting the SUPT-ICE and FIXER-CASE in the front of the maker up ( direction) and pulling the ICE-MAKER KIT out to the front ( direction). (Do not disassemble each component of the ICE-MAKER KIT. Otherwise, the setting value may be changed.) Wire housing 11-8) Assembly of Ice-Maker 1.
12. References Reference No. 1) Connection diagram of CABINET-DOOR Connection at Hinge-Upp of the Freezer Black Black Brown Brown Red Red Orange Orange Yellow Yellow Pink Pink Blue Blue Violet Violet Gray Gray White White Light-Blue Light-Blue Reference No. 2) Check of RELAY 3 contact 2 contact Measure after disassembly At first, disconnect the housing connected to the LOAD connector (MAIN PCB CN70, 71, 72) and then check and measure the following things. 1.
Reference No. 3) Check of LOAD Measure after disassembly Red Gray F-Defrost heater F-ROOM LAMP F-FAN After disconnect of the power cord from power consent and of the connectors, CN70, 71 and 72 from MAIN PCB, measure the followings. 1. Measure the resistance value between the load terminal and terminal as follows to judge the abnormality of load and wire connection.
Reference No. 5) Check method of DOOR S/W Perform the check when the power is supplied. DOOR S/W is consisted of 2 contacts circuit. 1 contact senses DOOR OPEN/ CLOSE at PCB by DC 5V and another has a role of ON/OFF of the inside lamp. Measuring terminal Measuring terminal To Fluorescent Lamp (Lamp Inside the Refrigerator) 1. Since there is a fluorescent lamp in the Refrigerator, at first, open the door of the Refrigerator to check whether the lamp is normally on.
Reference No. 6) Forced-Operation and Forced-Defrost Procedure This is a function for the immediate operation of COMP and F-FAN regardless of the temperature inside the Freezer. TEST S/W on PCB 1. Forced-Operation will be started by pushing a button on MAIN PCB located at the top of the refrigerator. 2. Buzzer sounds. This is a function for the operation of R-Defrost or the concurrent operation of F and R Defrost regardless of the setting for defrosting.
Reference No. 8) Conversion table of the resistance and voltage of sensor according to the temperature Voltage inputted to MICOM PORT may vary according to the H/W composition and this specification is the standardized one for the voltage on the use of 10 -F of the potential divider resistance.
13. Disassembly method of the refrigerator 13-1) How to disassemble the freezer and refrigerator FTA / DTA Ice-maker Interior Lamp(REF) Cover-Guard Remove the cover by rotating( ) driver. Remove the lamp by pulling it out and replace new one. After covering, assemble by rotating( ) driver toward the arrow direction. While pushing the cover to the left, slide it out by lifting it up. While supporting the ice-maker at front, lift it slightly toward direction and pull it straight out toward direction.
13-2) Disassembly of Evaporator of Freezer 1. After disassembly of the lamp cover for the freezer, disconnect wire housing from the lamp socket. 2. Disassemble and remove two cap-screws using(-) driver or the likes. 3. While holding the bottom of the EVAPCOVER FRONT and drawing it carefully toward the arrow direction, disassemble the cover by sliding it out at the raised spot.
14. Assembly and Disassembly of HINGE-UPP ASSÕY 13-4) Temperature controller 1. Structure of Hinge-Upp AssÕy SR-S24NTA Disassemble the temperature controller by detaching the snaps of the front cover of the temperature controller using (-) driver or the likes and pulling it to the front. Replace PCB base by disassembling the wire housing connected to PCB and removing 3 screws. Assembly is the reverse procedure of disassembly. SR-S24FTA 2.
15.
1 115-2) Refrigerating Room Door (SR-S25NTA) Refrigerator Room Door Components List (SR-S25NTA) No 74 Specifications QÕTY 1 DA64-10465A HANDLE-BASE FRE UPP Au coated 1 2 DA64-10464A HANDLE-BASE FRE LOW Au coated 1 3 DA64-10463A HANDLE POLY URETHAN 1 4 DA64-10471A HANDLE-TRIM FRE UPP ABS 1 5 DA64-10470A HANDLE-TRIM FRE LOW ABS 1 6 6002-000480 SCREW-TAP M4 10 11 SR-S25NTA 1 7 373 Items Code-No ASSÕY-FOAM DOOR FRE 8 DA63-30231A GASKET-DOOR FRE ASSÕY SF-PVC 1 9 DA63-1092
1 115-3) Door Parts (SR-S26NTA) Door Parts List (SR-S26NTA) No 76 Specifications QÕTY 1 DA64-10467A HANDLE-BASE FRE UPP Au coated 1 2 DA64-10466A HANDLE-BASE FRE LOW Au coated 1 3 DA64-10463A HANDLE POLY URETHAN 1 4 DA64-10471A HANDLE-TRIM FRE UPP ABS 1 5 DA64-10470A HANDLE-TRIM FRE LOW ABS 1 6 6002-000213 SCREW-TAPPING M4 12 11 7 375 Items Code-No ASSÕY-FOAM DOOR FRE 1 8 DA63-30232B GASKET-DOOR FRE ASSÕY SF-PVC 1 9 DA63-10925B COVER-GUARD GPPS 1 10 DA63-20282A GUA
15-4) Door Parts of Freezing Compartment (SR-S26NTA) Parts List (SR-S26NTA) No 78 Specifications QÕTY 1 DA64-10465A HANDLE-BASE FRE UPP Au coated 1 2 DA64-10464A HANDLE-BASE FRE LOW Au coated 1 3 DA64-10463A HANDLE POLY URETHAN 1 4 DA64-10469A HANDLE-TRIM FRE UPP ABS 1 5 DA64-10468A HANDLE-TRIM FRE LOW ABS 1 6 6002-000213 SCREW-TAPPING M4 12 11 SR-S26/28NTA 1 7 77 Items Code-No ASSÕY-FOAM DOOR FRE 8 DA63-30231B GASKET-DOOR FRE ASSÕY SF-PVC 1 9 DA63-20285A GUARD-FRE
1 15-5) Freezing Compartment (SR-S25/26NTA) Parts List of Freezing Compartment (SR-S25/26NTA) No 1 Specifications QÕTY 220V/50, 60Hz 1 DA59-40211B EVAPORATOR-FRE ASSÕY 240V/50Hz 1 DA59-40211F EVAPORATOR-FRE ASSÕY 127V/60Hz 1 DA59-40211C EVAPORATOR-FRE ASSÕY 115V/60Hz 1 DA63-10955G COVER-EVAP REAR ASSÕY 220V/50Hz, 1 DA63-10955K COVER-EVAP REAR ASSÕY 240V/50Hz 1 DA63-10955L COVER-EVAP REAR ASSÕY 127V/60Hz 1 DA63-10955J COVER-EVAP REAR ASSÕY 115V/60Hz 1 2-1 DA63-10934A COVER-EVAP REA
No Code-No Items Specifications QÕTY 4713-001054 LAMP 230V/60W 1 4713-001077 LAMP 125V/60W 1 4713-001053 LAMP 110V/60W 1 6 DA67-30266D CAP-SCREW PP(SC-93437R) 4 7 DA67-40203H ASSÕY TRAY-ICE NTA 1 7-1 DA64-40111B KNOB-TRAY ICE ABS(SC-9343R) 2 7-2 DA61-20136A SPRING-ICE MAKER STS 304 ID 1.
1 115-6) Door Parts List of Freezing Compartment (SR-S24FTA) Freezing Door Components List (SR-S24FTA) No 3 83 84 Code-No Items Specifications QÕTY 1 DA64-10465A HANDLE-BASE FRE UPP Au coated 1 2 DA64-10464A HANDLE-BASE FRE LOW Au coated 1 3 DA64-10463A HANDLE POLY URETHANE 1 4 DA64-10469A HANDLE-TRIM FRE UPP ABS 1 5 DA64-10468A HANDLE-TRIM FRE LOW ABS 1 6 6002-000213 SCREW(NORMAL)-TAPPING M4 12 11 7 DA91-10268A ASSÕY-FOAM DOOR FRE FTA 1 8 DA63-30231A GASKET-DOOR FRE ASS
1 15-7) FREEZING DOOR PARTS (SR-S25/27FTA) No Code-No Items Specifications QÕTY 33 DA63-30199A GASKET-COVER ICE SILICON 1 34 DA34-10124A SWITCH-MICRO 250V/5A 2 35 DA63-10508C COVER-MICRO SWITCH ABS 2 36 DA61-20143B SPRING-DISP WATER STS 304 1 37 DA64-40006B BUTTON-MICRO SWITCH NORYL 2 38 6002-000468 SCREW TAPPING M5 18 2 39 6002-000215 SCREW-TAP M4 16 2 40 DA67-30349A CAP-CHUTE, ICE ABS 1 41 DA71-70166A GUIDE-LEVER SILICON 1 42 DA63-10995A COVER-LAMP(DISP) MIPS 1 Remarks
Freezing Door Components List (SR-S25/27FTA) No Items Code-No Specifications QÕTY Remarks No Code-No Items Specifications QÕTY 1 DA64-10465A HANDLE-BASE FRE UPP Au coated 1 33 DA63-30199A GASKET-COVER ICE SILICON 1 2 DA64-10464A HANDLE-BASE FRE LOW Au coated 1 34 DA34-10124A SWITCH-MICRO 250V/5A 2 3 DA64-10463A HANDLE POLY URETHANE 1 35 DA63-10508C COVER-MICRO SWITCH ABS 2 4 DA64-10469A HANDLE-TRIM FRE UPP ABS 1 36 DA61-20143B SPRING-DISP WATER STS 304 1 5 DA64-10468A
1 15-8) Refrigerating Door Parts (SR-S24FTA) Refrigerating Door Parts List (SR-S24FTA) No Items Code-No Specifications 1 DA64-10467A HANDLE-BASE REF UPP Au coated 1 2 DA64-10466A HANDLE-BASE REF LOW Au coated 1 3 DA64-10463A HANDLE POLY URETHANE 1 4 DA64-10471A HANDLE-TRIM REF UPP ABS 1 5 DA64-10470A HANDLE-TRIM REF LOW ABS 1 6 6002-000213 SCREW-TAP M4 7 ASSÕY-FOAM DOOR REF 12 1 8 DA63-30232A GASKET-DOOR FRE ASSÕY SF-PVC 1 9 DA63-10925B COVER-GUARD GPPS 1 10 DA63-2027
1 15-9) REFRIGERATING DOOR PARTS (SR-S25/27FTA) No Code-No Items Specifications QÕTY 31 6002-000215 SCREW TAP M4 16 2 32 DA71-20171A FIXER-HOME BAR NY-66 1 33 6002-000213 SCREW-TAPPING TH4 12 ZPC 1 34 DA63-30195B GASKET-HOME BAR SF-PVC 1 35 DA63-30234A GASKET-HOME BAR, B SF-PVC 1 36 DA34-10121A SWITCH-DOOR 250V/0.
Refrigerating Door Parts List (SR-S25/27FTA) No Code-No Items Specifications QÕTY Remarks No Code-No Items Specifications 1 DA64-10467A HANDLE-BASE REF UPP Au coated 1 31 6002-000213 SCREW-TAPPING TH4 2 DA64-10466A HANDLE-BASE REF LOW Au coated 1 32 DA63-30195B GASKET-HOME BAR SF-PVC 1 3 DA64-10463A HANDLE POLY URETHANE 1 33 DA63-30234A GASKET-HOME BAR, B SF-PVC 1 4 DA64-10471A HANDLE-TRIM REF UPP ABS 1 34 DA34-10121A SWITCH-DOOR 250V/0.
1 15-10) Refrigerating Compartment (SR-S25/26NTA, SR-S24/25FTA) Parts List of Refrigerating Compartment (SR-S25/26NTA) No Code-No Items 220V/50, 60Hz/90W 1 DA59-40210B EVAPORATOR-REF ASSÕY 240V/50Hz/90W 1 DA59-40210E EVAPORATOR-REF ASSÕY 127V/60Hz/90W 1 DA59-40210C EVAPORATOR-REF ASSÕY 115V/60Hz/90W 1 DA63-10957G COVER-EVAP REAR ASSÕY(REF) 220V/50, 60Hz 1 DA63-10957L COVER-EVAP REAR ASSÕY(REF) 240V/50Hz 1 DA63-10957K COVER-EVAP REAR ASSÕY(REF) 127V/60Hz 1 DA63-10957J COVER-EVAP REAR
No 9 Code-No Items DA63-10959C COVER-DAMPER ASSÕY(REF) Specifications QÕTY NTA 1 9-1 DA63-10953C COVER-DAMPER REF PP(SC-93437R) 1 9-2 DA72-40447A INS(DAMPER) FOAM-PS 1 9-3 DA72-60378A SEAL-FOAM PE(REF) FOAM-PE 1 9-4 DA32-10104G SENSOR-ASSÕY(REF) 502AT, NTA 1 9-5 DA63-10936A COVER-SENSOR ABS 1 10 DA63-10960A COVER-VEG ASSÕY(UPP) NTA 1 10-1 DA63-10941A COVER-VEG(UPP) PP(SC-93437R) 10-2 DA63-30229B GASKET-COVER VEG(REAP) 10-3 DA63-30229A GASKET-COVER VEG(FRONT) Remarks No Code-No
1 15-11) CABINET PARTS CABINET Components List No 1 Specifications QÕTY ASSÕY CABI FOAM NTA 1 ASSÕY CABI FOAM FTA 1 DA61-10234C HINGE-LOW ASSÕY, L SHP1, T4.5 1 3 DA61-10235B HINGE-LOW ASSÕY, R SHP1, T4.
No Code-No Items Specifications QÕTY Remarks No Code-No Items Specifications QÕTY 21-1 DA71-60191A CHASSIS-CIMP SBHG1, T1.
1 1 15-12) Freezing Compartment (SR-S24/25FTA) Freezing Components List(SR-S24/25FTA) No Specifications QÕTY 220V/50,60Hz/200W 1 DA59-40211B EVAP-FRE ASSÕY 240V/50Hz/20W 1 DA59-40211F EVAP-FRE ASSÕY 127V/60Hz/200W 1 DA59-40211C EVAP-FRE ASSÕY 115V/60Hz/200W 1 DA63-10955K COVER-EVAP REAR ASSÕY 220V/50,60Hz 1 DA63-10955G COVER-EVAP REAR ASSÕY 240V/50Hz 1 DA63-10955L COVER-EVAP REAR ASSÕY 127V/60Hz 1 DA63-10955J COVER-EVAP REAR ASSÕY 115V/60Hz 1 2-1 DA63-10934A COVER-EVAP REAR, FRE
1 1 No Code-No Items Specifications QÕTY Remarks No Code-No Items Specifications QÕTY Remarks 4713-001054 LAMP 230V/60W 1 27 DA63-10948A COVER-MOTOR SOLENOID ABS 1 4713-001077 LAMP 125V/60W 1 28 DA75-900141A CUBE-SOLENOID 220V/50,60Hz 1 Packaged Type With No.30 4713-001053 LAMP 110V/60W 1 DA74-40151B CUBE-SOLENOID 230~240V/50Hz 1 Packaged Type With No.30 10 DA67-30266D CAP-SCREW PP(SC-93437R) 4 DA74-40151C CUBE-SOLENOID 110~127V/50,60Hz 1 Packaged Type With No.
1 1 15-13) FREEZING COMPARTMENT(SR-S27FTA) Parts List of Freezing Compartment (SR-S27FTA) No Specifications QÕTY Remarks 240V/200W 1 DA59-40211C EVAPORATOR-FRE ASSÕY 110V/200W 1 DA59-40211D EVAPORATOR-FRE ASSÕY 220V/200W 1 DA59-40211F EVAPORATOR-FRE ASSÕY 127V/200W 1 DA63-10955G COVER-EVAP REAR ASSÕY 220V 1 DA63-10955J COVER-EVAP REAR ASSÕY 110V 1 DA63-10955K COVER-EVAP REAR ASSÕY 240V 1 DA63-10955L COVER-EVAP REAR ASSÕY 127V 1 2-1 DA63-10934A COVER-EVAP REAR FRE ABS SCRAP 1 2
1 1 No Code-No Items Specifications QÕTY Remarks No Code-No Items Specifications QÕTY Remarks 4713-000194 LAMP 220V/60W 1 22 6002-000213 SCREW-TAPPING TH4 12 ZPC 10 4713-001054 LAMP 240V/60W 1 23 DA59-30104G ASSÕY-CRUSHED FTA 1 10 DA67-30266D CAP-SCREW PP(SC-93437R) 4 24 DA59-30103B ASSÕY-ICE MAKER FTA 1 11 DA63-10940A COVER-LAMP, FRE MIPS 1 25 DA61-70253A SUPT-ICE MAKER ABS 1 12 DA63-01003A COVER-DUCT PP(SC-93437R) 1 26 DA73-10620A PIPE-WATER HD-PE 1 13 DA67-10425D
1 1 15-14) REFRIGERATING COMPARTMENT(SR-S27FTA) Parts List of Refrigerating Compartment (SR-S27FTA) No Code-No Items Remarks 115V/90W 1 DA59-40210E EVAPORATOR-REF ASSÕY 127V/90W 1 DA59-40210A EVAPORATOR-REF ASSÕY 220V/90W 1 DA59-40210B EVAPORATOR-REF ASSÕY 240V/90W 1 DA63-10957J COVER-EVAP REAR ASSÕY(REF) 110V 1 DA63-10957K COVER-EVAP REAR ASSÕY(REF) 127V 1 DA63-10957G COVER-EVAP REAR ASSÕY(REF) 220V 1 DA63-10957L COVER-EVAP REAR ASSÕY(REF) 240V 1 2-1 DA63-10943A COVER-EVAP REAR,
1 1 No 9 Code-No Items Specifications DA63-10959D COVER-DAMPER ASSÕY(REF) QÕTY Remarks No 1 Code-No Items 19-2 DA63-40256B GROMMET-RAIL Specifications NY-66 2 Remarks SNA 9-1 DA63-10953A COVER-DAMPER, REF PP(SC-93437R) 1 9-2 DA72-40447A INS(DAMPER) FOAM-PS 1 SNA 20-1 DA61-60180A RAIL-LOW(R) HIPS(SC-93437R) 1 SNA 9-3 DA72-60378A SEAL-FOAM PE(REF) FOAM-PE 1 SNA 20-2 DA63-40256B GROMMET-RAIL NY-66 2 SNA 9-4 DA32-10104G SENSOR-ASSÕY(REF) 502AT 1 21 6002-000213 SCREW-TAPPING
116. Assembled state of Machine Room 17.
18. Installation of the water dispenser line 1) For automatic operation of the ice maker, water pressure of 1.4~4.5Kgf/ is required.(It is 2. Connect the water tube to water tube valve 6. Fix the purifier. acceptable if the disposable paper cup(177cc) can be filled up with water within a second.) 2) The water tube can be used by cutting to the desired length. Make sure that the tube is not bent. 3) Make the maximum length of the water tube to be 12m, if possible.
10. Check the amount of supplied water to the ice maker. 1) Remove the upper ice maker frome the refrigerator. The Method to control the amount of water supply to the ice maker 3. If S/W control is completed, check the amount of supplied water to the Ice Maker. 1. Disassemble the PCB panel at the top of he refrigerator. If the controlled amount of water supply is slightly below the optimum level, it doesnÕt matter for use.
19-2) PCB ASSÕY Component List Basic Model(SR-S24NTA) ITEMS REMARK EA TMP87C840N-4796 1 TOSHIBA DA09-30015A 29 C-ELECTRIC 470 02 VOLTAGE REGULATOR KA7812 1 SAMSUNG SEMICONDUCTOR 1202-000243 30 C-ELECTRIC 104 03 VOLTAGE REGULATOR KA7805 1 SAMSUNG SEMICONDUCTOR 1003-000274 31 R-CARBON 47 04 IC-LINER ULN2003A 2 ALLEGRO, T1 1003-000217 32 R-CARBON 220 05 LED-DRIVER uP2981C 1 NEC, ALLEGRO 1003-000217 33 R-CARBON 47K 06 IC-RESET KA7533 1 SAMSUNG SEMICONDUCTOR 1201-000001 34 R
16. Assembled state of Machine Room Additional components(to the basic type) : on the model with Ice Dispenser(SR-S24FTA) NO ITEMS Specification EA SUPPLIER CODE-NO 46 C-ELECTRIC 104 7 DONGYANG 2002-000780 47 R-CARBON 47K -J(1/4) 3 ABCO, HANRUK 2001-000055 48 R-CARBON 1.
20. Specification of major components in circuit 20-1) REGULATOR 3. TERMINAL 1A POSITIVE VOLTAGE REGULATORS The KA78XX series of three-terminal positive regulators are available in the TO-220 package and with several fixed output voltages, making them useful in a wide range of applications. Each type employs internal current limiting, thermal shutdown and safe area protection, making it essentially indestructible. If adequate heat sinking is provided, they can deliver over 1A output current.
1 ABSOLUTE MAXIMUM RATINGS(T =25 A unless otherwise specified) Characteristic Symbol Value Unit V1 V1 35 40 V V Thermal Resistance Junction-Cases ReJC 5 /W Thermal Resistance Junction-Air ReJA 65 /W Operating Junction Temperature Range KA78XX/A Operating Junction Temperature Range KA78XXI TOPR 0~ 125 -40~ 125 Storage Temperature Range TSTG -65~ 150 Input Voltage (for Vo = 5V to 18V) Input Voltage (for Vo = 24V) ELECTRICAL CHARACTERISTICS KA78-5/1 (REFER TO TEST CIRCUIT, T MIN
ELECTRICAL CHARACTERISTICS KA7812/I (Refer to test circuit, T MIN
20-2) RESETIC(KA7533) 3.3V VOLTAGE DETECTOR TO-92 The KA7533 prevents error of system from supply voltage below normal voltage level at the time the power on and instantane ous power off in systems. FEATURES Detecting against error operations at the power ON/OFF. Resetting function for the low voltage microprocessor. Checking low battery.
ABSOLUTE MAXIMUM RATINGS(T =25 A ) Symbol Value Unit Supply Voltage VCC -0.3~ 15.0 V Detecting Voltage VDET 3.3 V Hysteresis Voltage RHYS 50 mV Operating Temperature TOPR -30~ 75 Storage Temperature TSTG -50~ 150 PD 200 Characteristic Power Dissipation VDET/ T Detecting Voltage Temperature Coefficient ELECTRICAL CHARACTERISTICS(T =25 A Characteristic Symbol mW 0.01 /W ) Test Conditions Min Typ Max Unit 3.15 3.3 3.45 V V Detecting Voltage VDET RL=200 , VOL 0.
1 20-3) DRIVER IC(uPA2981C) uPA2981C, 2982C /CONNECTION DIAGRAM(Top View) I : Input O : Output VCC : Supply Voltage /EQUIVALENT CIRCUIT(1/8 uPA2981C uPA2982C V CC 50 V VO 50 V 15 V VI 30 V IO 500 mA/Unit W PT 1.4 VR 50 V IF 500 mA/Unit T OPT -30~+75 T STG -55~+150 ) VCC( IN ) OUT R1 GND( ) R1 = 3 (uPA2981C) R1 = 8.
1 20-4) DRIVER IC(ULN2003A) 2001THRD 2024 HIGH-VOLTAGE, HIGH-CURRENT DARLINGTON ARRAYS ULN20XXL ULN20XXA Ideally suited for interfacing beween low-level logic circuitry and multipe peripheral power loads, the Series ULN2000A/L high-voltage, high-current Darlington arrays feature continuous load current ratings to 600mA for each of the seven drivers. At an appropriate duty cycle depending on ambient temperature and number of drivers turned ON simultaneously, typical power loads totaling over 260W(400mA 7.
2001THRD 2024 HIGH-VOLTAGE, HIGH-CURRENT DARLINGTON ARRAYS DEVICE NUMBER DESIGNATION PARTIAL SCHEMATICS VCE(MAX) 50V 50V 95V IC(MAX) 500mA 600mA 500mA ULN2001A(Each Driver) Logic Part Number General Purpose PMOS, COMS ULN2001A* 5V ULN2003A* TTL, CMOS ULN2003L* 6-15V ULN2004A* COMS, PMOS ULN2004L* - ULN2023A* ULN2013A* ULN2023L* - ULN2024A Dwg. No. A-9595 Dwg. No.
1 20-5) RELAY(VSB-12TB) VSBRelay 16 Amps.
VSBRelay SAFETY STANDARD & FILE NUMBERS UL 508(File No. E56140. E108658) C22.2 NO.0, NO.14(File No. LR35579) Please be noted that UL/CSA rating may differ from the Standard ratings. Please request when the approval markings are required on the cover.
MEMO 132
Safefy Instruction o Service Unplug the refrigerator before making any repair or any replacement. Avoid the electric shock. Use the rated components on the replacement. Check the correct model, rated voltage, rated current, operating temperature and so on. On repair, be sure that the wires such as harness are bundled tightly and are not permeated by water... Bundle tightly wires in order not to be detached by the external force.
ELECTRONICS 272, Oseon-Dong, Kwangsan-Gu, Kwangju-City, Korea, 506-253 TEL : (062)950-6811, 6812 FAX : (062)950-6829 Samsung Electronics Co., Ltd. Refrigerator Division 1998. 4 Printed in Korea DA68 - 60330B REV (0.