Specifications
3-14
Alignment and Adjustments
Samsung Electronics
3-3-5(d) Check After Adjustment
1) Tracking Check
Œ Playback the alignment tape.
´ Confirm that the minimum amplitude value(E min.)is 80% of the maximum value(E max.) or larger.
(Fig. 3-19)
ˇ Confirm that no large fluctuation occur on the waveform. (Fig. 3-20)
2) CUE and REV Check
Œ Playback the alignment tape, and set to REV mode.
Confirm that the waveform peaks have a uniform Pitch. (Fig. 3-21 A)
If the track pitch is not uniform, do section 3-3-5(b) (Tracking adjustment).
´ Set to CUE mode.
Confirm that the waveform peaks still have a uniform pitch. (Fig. 3-21 B)
If the track pitch is not uniform, do section 3-3-5(b) (Tracking Adjustment).
Emin Emax
Emax
Emin
80(%)
Fig. 3-19
A
A
C
C
C
1
8
Fig. 3-20
abc a
abc
bc
Fig. 3-21