SMM-15FDQ/21FDQ_ENG_Cover 9/19/03 6:18 PM Page 1 COLOR DUAL QUAD OBSERVATION SYSYTEM SMM-15FDQ/21FDQ User Guide
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 2 IMPORTANT SAFETY INSTRUCTIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Read these instructions. Keep these Instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 3 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 4 IMPORTANT SAFEGUARDS Caution Power source is indicated on the rear of the set. It contains high-voltage parts. If you remove the cover, it may cause fire or electric shock. Do not remove the cover by yourself. (Control switches are at the front of the monitor.) 1. Read Instructions : All the safety and operating instructions should be read before the appliance is operated. 2.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 5 8. Accessories : Do not place this monitor on an unstable cart, stand, tripod, bracket, or table. The monitor may fall, causing serious injury to a child or adult, and serious damage to the appliance. Use only with a cart, stand, tripod. bracket, or table recommended by Samsung, or sold with the monitor. Any mounting of the monitor should follow Samsung’s instructions, and should use a mounting accessory recommended by Samsung. 9.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 6 13. Lightning : For added protection for this monitor during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the cable system. This will prevent damage to the monitor due to lightning and power-line surges. 14. Overloading : Do not overload wall outlets and extension cords as this can result in a risk of fire of electric shock. 15.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 7 18. Replacement Parts : When replacement parts are required, be sure the service technician has used replacement parts specified by Samsung or have the same characteristics as the original parts. Unauthorized substitutions may result in fire, electric shock or other hazards. 19.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 8 Information to user Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
SMM-15FDQ/21FDQ_ENG 9/19/03 6:19 PM Page 9 The party responsible for product compliance: SAMSUNG ELECTRONICS CO., LTD. America QA Lab of Samsung 3351 Michelson Drive, Suite #290, Irvine, CA92612 USA IC Compliance Notice This Class (A) digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 11 Chapter 3: Setting each item function at SETUP MENU 3-1) ADJUST MENU function and setting method .................... 33 3-2) DATE/TIME MENU Function setting ................................ 34 3-3) DWELL TIME MENU function setting .............................. 34 3-4) DISPLAY MENU function setting ..................................... 35 3-5) TITLE MENU Function setting........................................... 36 3-6) ALARM MENU Function setting...........
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 12 Chapter 1: System Components and Installation 1-1) Environmental requirements for installation and safety This section describes the environmental requirements for safe installation and use. Install the product on a flat table or in a rack. It should be used only when level and should not be used when stood vertically or obliquely.
1-2) System Components The system consists of the following: MONITOR CAMERA BRACKET STANDARD CAMERA PIR CAMERA POWER CODE & INSTALLATION MANUAL CAMERA CABLE • Check whether all the following devices and accessories are included with the main system.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 15 e. SENSOR jack Used to connect the sensor to the camera. f. Speaker It outputs the sound signal which was transfered from the monitor. • PIN configuration of the DOME CAMERA is the same as the STANDARD CAMERA. • But, DOME CAMERA does not provide ALARM JACK. 2) Installing Syandard Camera (SOD14C) SOD14C s camera can be attached to the wall, ceiling or shelf using the camera mount bracket (SBR-110).
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 16 3) PIR Camera composition (Top) (Bottom) 3 5 4 1 2 ① Lens It has a focal length of 3.8mm and makes it possible for you to observe a relatively wide area. ➁ Speaker It outputs the sound signal which was transfered from the monitor. ➂ Fresnel Lens An infrared focusing lens for increasing the sensitivity of the built-in PIR sensor.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 17 ➃ 6-pin modular jack Used to connect the camera to the monitor. PIN NUMBER SPEC ! SPEAKER(HOT) @ VIDEO_OUT # GND $ SPEAKER(COLD) % AUDIO_OUT/ALARM_OUT ^ 12V DC ⑤ 5-Pin Terminal Block A terminal block for supplying backup power for the PIR sensor operation during power outages and for transmitting the relay signals to external devices during the PIR sensor operation.
(Sensor Detection Angle & Area) 1) Vertical View Pattern 2) Horizontal View Pattern 18
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 19 (Inside) 6 8 7 9 ➅ Function Switch A function switch for the PIR sensor operation. PIN ON ! OFF S1 ! S2 @ S3 # S4 $ Function @ Sensor Sensitivity On, On : Low On, Off : Normal Off, On : Normal Off, Off : High # Alarm Led On/Off (Sensor On) $ Sensor On/Off ⑦ PIR Sensor A thermal heat sensor that detects infrared radiation projected by warm objects.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 20 Camera installation Hints 1. Do not install directly towards rising or setting sun. Can cause burn or damage to internal options. 2. Do not limit desired detection zone by interference of curtains, screens, potted plants, etc. 3. Also, do not locate it in front of source of water/oil vapors. Avoid placement of heat source inside detection zone 4. Do not install outdoors.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 21 4) Installing the PIR Camera (SMM-PIRCAM) 1. Choose an installation site that can sufficiently support 5 times the weight of the equipments to be installed. 2. Remove the screw (BH M2.6) at the bottom of the main unit by turning it counterclockwise, and then lift the assy-case front as you push it upward to detach it from the case-rear. (❊ Do not apply excessive force, as doing so may damage the inside assembly.❊) Assy-case front Screw (BH M2.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 22 4. Connect the Camera connector(RJ-11) cable to the case-rear as well as the cable to be connected to the terminal. 5. Align the two holes of the case-rear to the holes of the plastic anchors, and then fasten the screw-tappings (BH M3 X 30).
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 23 6. Adjust the direction of the lens. 1) Use the cross (+) screw driver to turn the screw (indicated by the arrow in the illustration) counterclockwise slightly. The lens body will move. 2) Tilt the lens body down about 10° from the horizontal, and then turn the screw clockwise to fasten it. Screw (HB M4 x L8) 7. Assemble the assy-case front onto the case-rear as shown in the illustration. Fasten the assy-case front to the case-rear with the screw (BH M2.
SMM-15FDQ/21FDQ_ENG 9/19/03 • 4:50 PM Page 25 Loosen the handle by turning it in a counter clockwise direction and then adjust the camera position . Tighten the handle, turning it clockwise, and lock the camera in position. • Connect the camera cable to the camera. Handle (3) Specifications Use : Indoor Installation : Wall or Ceiling Dimensions : 57 (W) X 47.2(H) X 100.
1-4) CAMERA Composition and Connecting Method to MONITOR After positioning monitor and installing four cameras to a desired location, please connect CAMERA to MONITOR through CAMERA CABLE (MCB-60) as shown in the below figure. Please check whether or not it is properly connected. Connection status checking method : • Turn on the monitor after connecting cameras, and check if camera image is displayed. The initial screen mode of monitor is quad mode.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 27 1-5) External terminal connecting method for CAMERA and MONITOR 1) External terminal connecting method for CAMERA • An additional PIR sensor or external sensor can also be connected. • The additional PIR sensor can be connected as shown in the above graphic. • Sensor’s trigger signal is NO (Normal Open). • Sensor is not supplied.
f) Connect the TRIGGER plug to the REC TRIGGER OUT terminal of the VCR. g) Connect the A/O (HOT) terminal on the rear panel to the Alarm IN terminal of the VCR. h) Connect the A/O (COLD) terminal on the rear panel to the Ground terminal of the VCR. i) Connect the A/R terminal on the rear panel to the Alarm Reset terminal of the VCR. j) Connect the G (ground) terminal on the rear panel to the Ground terminal of the VCR.
Chapter 2: MONITOR FRONT PANEL KEY Function and Using Method Front Panel 2-1) TALK KEY TALK KEY allows users to transmit voice signal to intended camera by inputting voice with built-in √ MIC in the front of the monitor. For this function, select a target camera with the œENTER√ SWITCH on the FRONT PANEL, and press AUD/SP SEL KEY. At this time, if a voice signal is generated through the MIC with the TALK KEY pressed, the signal will be transmitted to the camera.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 30 2-4) POWER SAVE- KEY Allows users to set POWER SAVE MODE of monitor. PICTURE screen is off when the POWER SAVE KEY is pressed, and the ON/OFF status of the monitor can be judged through LED ON/OFF status. Users can exit from POWER SAVE MODE by pressing POWER SAVE BUTTON again under picture “OFF” status. POWER SAVE MODE is automatically cancelled and picture is “ON” when an event such as an alarm or loss at POWER SAVE MODE occurs.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 31 2-8) PIP- KEY Can be used to see the main screen while Single screen is displayed. The main screen can be changed and transfered to another channel while PIP is working. Please refer to "CHAPTER 4. DISPLAY MODE SETTING" for PIP function and details. 2-9) FREEZE- KEY This key allows users to see a target camera picture at PAUSE MODE.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 32 2-13) ENTER- KEY √ key, it allows users to 1. enter SET UP MENU movement and As a multi functional œENTER√ SETTING MODE and set data, and 2. display single camera picture. Please refer to the below picture. • œENTER√ √ SWITCH using method at MENU setting Used to change data value after moving to target menu and entering setting mode by turning switch left or right. • Used to enter target setting mode by pressing switch.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 33 Chapter 3: Setting each item function at SETUP MENU Pressing the MENU BUTTON of the FRONT PANEL allows users to enter SETUP MENU and see the following menu OSD box. Setting method of each SETUP MENU function and operation is as follows. 06/01/03 SETUP 13:14:00 MENU 1. ADJUST 2. DATE/TIME 3. DWELL TIME 4. DISPLAY 5. TITLE 6. ALARM 7.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 34 3-2) DATE/TIME MENU Function setting • Function: Sets the display date format and current time. • √ SWITCH at setup menu, Setting method :Move to #2. DATE/TIME MENU by using œENTER√ then press the ENTER SWITCH to display the OSD as shown in the below figure. (The figure shows the initial setting status.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 35 3-4) DISPLAY MENU function setting • Function: Allows users to select the color and ON/OFF of borderline at QUAD DISPLAY. • √ SWITCH at Setting method: Move to #4. DISPLAY SETTING MENU by using œENTER√ SETUP MENU, then press the ENTER SWITCH to display the OSD as shown in the figure below. (The figure shows the initial setting status.) 06/01/03 DISPLAY 13:14:00 SETTING BORDER BORDER COLOR PIP POSITION ON BLACK T-LEFT √ SWITCH, and change the set value.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 36 3-5) TITLE MENU Function setting • Function: Set the title of each camera at your discretion. • √ SWITCH at SETUP MENU, Setting method: Move to #5. TITLE MENU by using œENTER√ and press the ENTER SWITCH to display the OSD as shown in the figure below. (The figure shows the initial setting status.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 37 3-6) ALARM MENU Function setting • Function: Allows users to set the ALARM MODE for each camera. • √ SWITCH at SETUP Setting method: Move to #6. ALARM MENU by using œENTER√ MENU, and press the ENTER SWITCH to display the OSD as shown in the figure below. (The figure shows the initial setting status.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 38 3-7) VIEW EVENT LOG MENU function and setting method • Function: Displays the time and date of camera event and type of event. • √ SWITCH at Setting method: Move to #7. VIEW EVENT LOG MENU by using œENTER√ SETUP MENU, then press the ENTER SWITCH to display the OSD as shown in the figure below. (The figure shows the initial setting status.) 06/01/03 Sequence of event happening Camera No. that event happened.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 39 Chapter 4: DISPLAY MODE setting method 4-1) SINGLE SCREEN DISPLAY Initial display mode of monitor is QUAD A. In case users want to see the camera image at full mode, √ SWITCH left and right. After that, press the ENTER select a target camera by turning œENTER√ √ SWITCH and selected camera image will be displayed at full screen. If users turn the œENTER√ SWITCH left / right at SINGLE DISPLAY MODE at this time, they can see another camera image at full screen.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 40 4-2) QUAD MODE DISPLAY Users can switch SINGLE DISPLAY MODE and SEQUENTIAL DISPLAY MODE to QUAD DISPLAY MODE, or QUAD A (QUAD B) to QUAD B (QUAD A), or PIP MODE to QUAD MODE, press the QUAD/PAGE KEY.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 41 4-3) AUTO SEQUENTIAL DISPLAY MODE Pressing on the SEQUENCE KEY on the front allows screen to automatically switch to SINGLE MODE full screen or QUAD MODE. (‘no-signal’ channels will be skipped while single screen is auto-switching.) If the DWELL TIME SETTING of SETUP MENU is set to 3 seconds and the SEQUENCE KEY is pressed at this time, the operation will be carried out as follows.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 42 4-4) PIP MODE DISPLAY Can be used to see PIP screen in Single screen mode. √ on PIP screen ,the main screen will change. If you press the œENTER√ √ If you press the œENTER√ to the left and right,the main screen can be transferred to another channel. Sub-screen location can be selected on DISPLAY MENU in SETUP MENU.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 43 4-5) ZOOM MODE DISPLAY When users want to see zoomed image of a specific area of the display, press the ZOOM KEY in the √ SWITCH left and front to display zoom selection area. Select zoom target area by turning œENTER√ right, and press the ENTER SWITCH, then, the selected area will be displayed at full single mode with zoomed area doubled. At zoom function operation at SINGLE DISPLAY MODE (CH2), the operation will be carried out as shown in figure below.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 44 Chapter 5: Each product feature SOD14C : Standard Camera Model Name SOD14C Broadcasting System NTSC STANDARD Imaging Device 1/4 ”SUPER HAD IT CCD Effective Pixels S 510(H) x 492(V) ynchronization Internal Resolution H :330 TV Lines, V: 350 TV Lines Signal Output VBS 1.0Vp-p(75ohms composite) S/N Ratio ≤ 48 dB Minimum Scene Illumination 2lux(F2.0, 50 IRE) Gamma Correction 0.45 Lens Focal Length (f) : 3.8mm, Aperture Ratio (F) : 2.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 45 SOD14DC : Standard Camera Model Name SOD14DC Broadcasting System NTSC STANDARD Imaging Device 1/4” SUPER HAD IT CCD Effective Pixels 510(H) x 492(V) Synchronization Internal Resolution H :330 TV Lines, V: 350 TV Lines Signal Output VBS 1.0Vp-p(75ohms composite) S/N Ratio ≤ 48 dB Minimum Scene Illumination 2lux(F2.0, 50 IRE) Gamma Correction 0.45 Lens Focal Length (f) : 3.8mm, Aperture Ratio (F) : 2.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 46 SMM-PIRCAM : PIR Camera Model Name Broadcasting System Imaging Device SMM-PIRCAM, SMM-PIRCAMBW SMM-PIRCAM SMM-PIRCAMBW : EIA Standard SMM-PIRCAM : 1/4'' Color IT CCD SMM-PIRCAMBW : 1/3'' B/W IT CCD Effective Pixels 537(H) X 505(V) Synchronization Internal Resolution : NTSC Standard SMM-PIRCAM : 330 TV Lines(H), 350 TV Lines(V) SMM-PIRCAMBW : 380 TV Lines(H), 350 TV Lines(V) Signal Output VBS 1.
SMM-15FDQ/21FDQ_ENG 9/19/03 4:50 PM Page 47 OBSERVATION MONITOR (SSC-21DQ) Video Input • CAMERA 8 Input: 1.0Vp-p(CVBS), 75Ω (vertical), • VCR 1 Input (to Video Out of VCR) : 1.0Vp-p, 75Ω (vertical), Video Output • BNC 4 Output: 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS • VCR 1 Output: 1.
SMM-15FDQ/21FDQ_ENG_Cover Samsung CCTV dba GV1 1621 West Crosby, Suite 104 Carrollton, TX. 75006 PHONE : 866.492.8246 9/19/03 8:20 AM Page 2 Part No.
SMM-15FDQ/21FDQ_ENG_Cover Samsung CCTV dba GV1 1621 West Crosby, Suite 104 Carrollton, TX. 75006 PHONE : 866.492.8246 9/19/03 6:18 PM Page 2 Part No.