HD-SDI CAMERA User Manual SCB-6000
HD-SDI Camera User Manual Copyright ©2011 Samsung Techwin Co., Ltd. All rights reserved. Trademark is the registered logo of Samsung Techwin Co., Ltd. The name of this product is the registered trademark of Samsung Techwin Co., Ltd. Other trademarks mentioned in this manual are the registered trademark of their respective company. Restriction Samsung Techwin Co., Ltd shall reserve the copyright of this document.
overview IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. ● OVERVIEW 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
overview WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT THROUGH THE VENTILATION GRILLS OR OTHER OPENNINGS ON THE EQUIPMENT. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus. CAUTION CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK).
Class construction An apparatus with CLASS construction shall be connected to a MAINS socket outlet with a protective earthing connection. Batteries(battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like. Disconnection Device Disconnect the main plug from the apparatus, if it’s defected. And please call a repair man in your location. When used outside of the U.S., it may be used HAR code with fittings of an approved agency is employed.
overview Please read the following recommend safety precautions carefully. Do not place this apparatus on an uneven surface. Do not install on a surface where it is exposed to direct sunlight, near heating equipment or heavy cold area. Do not place this apparatus near conductive material. Do not attempt to service this apparatus yourself. Do not place a glass of water on the product. Do not install near any magnetic sources. Do not block any ventilation openings.
CONTENTS OVERVIEW INSTALLATION & CONNECTION Important Safety Instructions Product Features What’s Included At a Glance 13 15 Mounting the Lens Connecting with other Device 18 19 Menu Configuration Menu Setup 32 34 35 Specification Product Overview Troubleshooting 13 OPERATING YOUR CAMERA 18 APPENDIX 32 English _7 ● OVERVIEW 3 3 8 9 10
overview PRODUCT FEATURES • Supports Full HD-SDI Video By adopting a diagonal 6mm (1/3”) 2M pixel CMOS, the camera produces clear picture quality. • Excellent low-illumination image quality By adopting high-sensitive colour CMOS, the camera provides clear image quality under a severe low illumination condition of 0.017 Lux (with SENS-UP, x60).
WHAT’S INCLUDED Check if the main unit and all the following accessories are included in the product package.
overview AT A GLANCE Front Side Item Description Camera Holder (Mount) Holes Used when you mount the camera onto the bracket by fixing the camera holder (mount) adaptor with the bracket. b Auto Iris Lens (Optional) Installed on the lens adaptor. c Auto Iris Lens Connector Used to supply power and output signal to control the iris of the lens. M Wipe out a dirty surface of the lens softly with a lens tissue or cloth to which you have applied ethanol.
Rear Side ● OVERVIEW HD-SDI POWER C-Video 1 2 3 4 5 1 : GND 4 : RS-485+ 2 : EXT_D/N 5 : RS-4853 : MD_OUT Item DC 12V AC 24V GND Description HD-SDI Video Out terminal BNC terminal for HD-SDI video signal output. b Power LED This lamp turns green when the proper power is applied to the camera. c C-VIDEO Analogue video output terminal of C-Video. Use a monitor cable for testing the camera with a portable display.
overview Item Description Power Port Used to plug the power cable. GND Used for earth-grounding. I/O Port 12_ overview 1:GND Earth-grounding port for external signal. 2:EXT_D/N External signal input port for Day/Night mode setup. 3:MD_OUT Output port that signals when a motion is detected. 4:RS-485+ Signal port for RS-485 communication. 5:RS-485– Signal port for RS-485 communication.
installation & connection MOUNTING THE LENS Disconnect the power before proceeding. The C lens and CS lens are not included in the product package. J If using a normal commercial lens, you may encounter out of focus when switching to BW mode . To prevent this, it is recommended to use the IR mega lens. Mounting the CS lens Turn the optional CS lens clockwise to insert it. CS Lens Mounting the C lens Turn the C mount adaptor clockwise to insert it and do the same with the C lens.
installation & connection Connecting the Auto Iris Lens connector Insert the lens connector into the corresponding hole of the camera. Focusing Turn the lens left or right to control the zoom and focus the lens so that you can view a clear, sharp object.
CONNECTING WITH OTHER DEVICE ● INSTALLATION & CONNECTION HD-SDI Monitor HD-SDI POWER C-Video 1 2 3 4 5 Day/Night mode controller 1 : GND 4 : RS-485+ 2 : EXT_D/N 5 : RS-4853 : MD_OUT DC 12V AC 24V GND Test monitor for installation Motion detection output device Connecting to the monitor Connect the video out port of the camera to the video input port of the monitor. M In the initial installation of the camera, you can connect the camera to the monitor for checking the connection status.
installation & connection External Day/Night Switching Input Day/Night mode of the camera can be switched by signal from an external device. M To use this function, setting of the camera should be set to the . (Page 27) Motion Detection Signal Out Upon a motion detection, the port outputs signal for an external device for display or operation. When a motion is detected, the port outputs 3.3V signal. M To use this function, setting of the camera should be set to .
Resistance of copper wire [at 20°C (68°F)] Wire specification (AWG) #24(0.22mm2) #22(0.33mm2) #20(0.52mm2) #18(0.83mm2) 0.018 0.078 0.050 0.030 0.028 0.018 0.011 0.006 Recommended Distance (m) Less than 20 Less than 30 Less than 30 Less than 30 • As shown in the table above, you may encounter a voltage-sag depending on the wire length. If you use an excessively long wire for camera connection, the camera may not work properly.
Operating Your Camera MENU CONFIGURATION MAIN SETUP • DC • MANUAL • BRIGHTNESS • SHUTTER • SENS-UP • RETURN • ATW • OUTDOOR • MANUAL • AWC ➝ SET SSDR • OFF • ON BACKLIGHT • OFF • BLC SSNR3 • ON • OFF • AUTO • EXTERN • COLOR • CAM TITLE • IMAGE ADJ • MOTION DET • PRIVACY • COMM ADJ • LANGUAGE • RESET • RETURN LENS • AGC EXPOSURE • INDOOR WHITE BAL • HLC DAY/NIGHT • B/W SPECIAL EXIT • EXIT 18_ Operating Your Camera
MENU SETUP To configure the camera’s function settings, use the button on the rear side of the product. ● OPERATING YOUR CAMERA HD-SDI POWER C-Video 1 2 3 4 5 1 : GND 4 : RS-485+ 2 : EXT_D/N 5 : RS-4853 : MD_OUT DC 12V AC 24V GND • ▲▼ : Moves up/down in menu. • ◄► : Moves right/left in menu. • SET : Press the switch to set the function in camera menu. To move to a sub-menu item in the menu, press this switch. 1. Press the SET button. • Enters the function menu.
Operating Your Camera 3. Use the Up/Down buttons to select a desired function. • Move the button right or left to display available values or settings. Set the desired setting value using the button. 4. To finish, select and press the SET button. M An item with the icon also has sub menus. To select a sub menu, select an item with the icon and press the Function Setup switch. An item with the --- icon is unavailable due to function settings.
EXPOSURE 2. Select a desired mode using the Function Setup switch. • BRIGHTNESS : Adjust the screen brightness. MAIN SETUP 1. ► 2. 3. 4. 5. 6. 7. 8. 9. LENS EXPOSURE WHITE BAL SSDR BACKLIGHT SSNR3 DAY/NIGHT SPECIAL EXIT 1. ► 2. 3. 4. 5. BRIGHTNESS SHUTTER AGC SENS-UP RETURN • SHUTTER : You can select the shutter. - – – – : 1/30sec - A.FLK : Select this when you experience picture flicker, this happen when there is a clash with the installed lighting frequency.
Operating Your Camera • AGC(AUTO GAIN CONTROL) : The higher the gain level, the brighter the screen but the greater the noise. - OFF : Not being used - Low : Allows automatic gain control from 5.3dB to 20dB. - Medium : Allows automatic gain control from 5.3dB to 26dB. - High : Allows automatic gain control from 5.3dB to 32dB. • SENS-UP : When it is night or dark, the camera automatically detects the light level and maintains a clear picture if this mode is activated.
WHITE BAL (WHITE BALANCE) Use the White Balance function to adjust the screen color. 2. Select a desired mode using the Function Setup switch. Select one of the following 5 modes, as appropriate for your purpose. MAIN SETUP 1. 2. ► 3. 4. 5. 6. 7. 8. 9. LENS EXPOSURE WHITE BAL SSDR BACKLIGHT SSNR3 DAY/NIGHT SPECIAL EXIT DC ATW ON OFF ON AUTO • ATW : Select this when the color temperature is between 2,400˚K and 11,000˚K. • OUTDOOR : Select this when the color temperature is between 1,700˚K and 11,000˚K.
Operating Your Camera SSDR (SAMSUNG SUPER DYNAMIC RANGE) SSDR illuminates darker areas of an image while retaining the same light level for brighter areas to even out the overall brightness of images with high contrast between bright and dark areas. 1. When the SETUP menu screen is displayed, select by using the Function Setup switch so that the arrow indicates . 2. Use the Function Setup switch to change the SSDR level in the sub menu according to the contrast between bright and dark areas.
BACKLIGHT This camera is designed so that it delivers a distinctive subject and background at the same time, even when the subject is in backlight, by adopting a function of the proprietary WN2 DSP chip. 2. Select a desired mode using the Function Setup switch depending on the camera purpose. • BLC : Enables a user to select a desired area on a picture and view that area more clearly. - LEVEL : Adjust level of the BLC function. MAIN SETUP 1. 2. 3. 4. ► 5. 6. 7. 8. 9.
Operating Your Camera SSNR3 This function reduces the background noise in a low luminance environment. 1. When the SETUP menu screen is displayed, select by using the Function Setup switch so that the arrow indicates . 2. Select a desired mode using the Function Setup switch. • ON : Activates SSNR3 so that noise is reduced. • OFF : Deactivates SSNR3. Noise is not reduced. MAIN SETUP 1. 2. 3. 4. 5. ► 6. 7. 8. 9.
AUTO SETUP ► 1. COLOR B/W DWELL TIME DURATION 2. COLOR B/W DWELL TIME DURATION 3. SPECIAL 5 SEC SLOW 10 SEC SLOW - DURATION : Adjust the brightness of the lighting where the mode switch occurs. • EXTERN : Control the image modes of Color and B/W when an external controller is synchronized via the Alarm In port. J When AGC in the EXPOSURE menu is ‘OFF’, ‘---’ mode operates as selecting ‘AUTO’ mode cannot be selected. SPECIAL 1.
Operating Your Camera • CAM TITLE : If you enter a title, the title will appear on the monitor. 1) If the SPECIAL menu screen is displayed, use the Function Setup switch so that the arrow indicates . 2) Set it to by using the Function Setup switch. 3) Press the Function Setup switch. CAM TITLE SETUP A N a n – ← B O b o .
• IMAGE ADJ : 1) When the SPECIAL menu screen is displayed, select by using the Function Setup switch so that the arrow indicates . SPECIAL CAM TITLE IMAGE ADJ MOTION DET PRIVACY COMM ADJ LANGUAGE RESET RETURN ON ATW ON ON ENGLISH 2) Select a desired mode using the Function Setup switch. - MONITOR : Please change the settings value of video appropriate to your monitor. • LCD : Please select this menu item when using an LCD monitor.
Operating Your Camera • MOTION DET : This product has a feature that allows you to observe movement of objects in 4 different areas on the screen, and the words appear on the screen when movement is detected. You can monitor activity more efficient. 1) When the SPECIAL menu screen is displayed, press the Function Setup switch so that the arrow indicates . MOTION DET ► 1. 2. 3. 4. 5. 6. 7. 8. 9. AREA MODE ALARM OUT TOP BOTTOM LEFT RIGHT SENSITIVITY RETURN * .... .... .... .... ...
COMM SETUP ► 1. 2. 3. 4. 5. 6. 7. PROTOCOL CAM ID BAUD RATE UART MODE DISP ID RET PKT RETURN SAMSUNG-T 1 * .... .... .... .... 9600 8-N-1 OFF ENABLE 2) Set up the mode using the Function Setup switch. - PROTOCOL : Select the communication PROTOCOL. (SAMSUNG-T, SAMSUNG-E, Pelco-D, Pelco-P, Bosch, Honeywell, Vicon, Panasonic, GE, AD) - CAM ID : Determines the camera's identification number (between 0 and 255). - BAUD RATE : You can select 2400/4800/9600/19200/38400/57600 bps.
appendix SPECIFICATION Items Video Description Video 1/3" Progressive Scan CMOS Total Pixels 2,010(H) x 1,108(V), 2.2M Pixels Effective Pixels 1,944(H) x 1,092(V), 2.1M Pixels Scanning System Progressiv Scan Min. Illumination Color : 1Lux @ F1.2, 0.017 Lux (Sens-up, 60x) B/W : 0.1 Lux @ F1.2, 0.
Items Environmenta Privacy Masking Off / On (16 Rect-angle zones) Sens-up (Frame Integration) 2x ~ 60x Gain Control Off / Low / Middle / High White Balance ATW / Outdoor / Indoor / Manual / AWC (1,700K° ~ 11,000K°) Electronic Shutter Speed Esc / A.
appendix PRODUCT OVERVIEW Unit : mm (inch) 60(2.36") 72(2.83") 138.6 (5.45") 136.8 (5.
TROUBLESHOOTING PROBLEM SOLUTION Nothing appears on the screen. When the camera’s HD-SDI BNC output is directly connected to the monitor’s BNC terminal: Make sure the monitor supports HD-SDI signal input. When the camera’s HD-SDI BNC output is connected to the DVR: Make sure the DVR supports HD-SDI signal input. HD-SDI output is converted into other format such as DVI and VGA by using video converter: Make sure the converter’s HD-SDI input format supports the product’s output video format.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
SALES NETWORK SAMSUNG TECHWIN CO., LTD. Samsungtechwin R&D Center, 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea, 463-400 TEL : +82-70-7147-8740~60 FAX : +82-31-8018-3745 SAMSUNG TECHWIN AMERICA Inc. 100 Challenger Rd. Suite 700 Ridgefield Park, NJ 07660 Toll Free : +1-877-213-1222 Direct : +1-201-325-6920 Fax : +1-201-373-0124 www.samsungcctvusa.com www.samsungtechwin.com www.samsungsecurity.com SAMSUNG TECHWIN EUROPE LTD.