Installation guide

Minimum
dimensions
If
overhead
cabinets
are
provided,
a
range
hood
should
also
be
provided
waanna
that
projects
horizontally
a
minimum
of
5
in
(12.7
cm)
beyond
the
front
of
the
cabinets.
This
will
dissipate
any
heat
buildup
in
the
overhead
cabinets
to
prevent
death,
personal
injury,
and/or
fire
hazard.
The
ventilating
hood
must
be
constructed
of
sheet
metal
not
less
then
0.0122"
thick.
Install
above
the
cooktop
with
a
clearance
of
not
less
than
1/4"
between
the
hood
and
the
underside
of
the
combustible
material
or
metal
cabinet.
The
hood
must
be
at
least
as
wide
as
the
appliance
and
centered
over
the
appliance.
Clearance
between
the
cooking
surface
and
the
ventilation
nood
surface
must
never
be
less
than
24
inches.
Exception
:
Installation
of
a
listed
microwave
oven
or
cooking
appliance
over
the
cooktop
shall
conform
to
the
installations
packed
with
that
appliance.
®
30-in
(101.6-cm)
minimum
clearance
between
the
top
of
the
cooking
surface
and
the
bottom
of
an
unprotected
wood
or
metal
cabinet;
or
If
no
30-in(101.6-cm)
minimum
clearance,
24-in
(61-cm)
minimum
when
the
bottom
of
the
wood
or
metal
cabinet
is
protected
by
not
less
than
0.25-in
(0.64-cm)
flame-retardant
millboard
covered
with
not
less
than
no.
28
MSG
sheet
steel,
0.015-in
(0.038-cm)
stainless
steel,
0.024-in
(0.061
-
cm)
aluminum,
or
0.020-in
(0.051-cm)
copper.
®
18-in
(45.7-cm)
minimum
between
the
countertop
and
the
adjacent
cabinet
bottom.
Recommended
locations
for
gas
piping
and
electrical
outlets
(For
models
FX710BGS, FX510BGS,
and
NX583GOVBSR
/
NX583GOVBBB
/
NX583GO0VBWW)
Recommended
area
oN
«
for
120
V
electrical
outlet
on
rear
wall.
2inx2in
(5.1
cm
x
5.1
om)
17
inx
Qin
(43.2
com
x
22.9
cm)
Gas
Wall
Area
~
T7inx
2
m™
NA
Uadomn
sto
cm)
~sGas-Figor
WOK
Recommended
area
for
through-the-wall
and
through-the-floor
connection
of
gas
pipe
stub
and
shut-off
valve.
22_
installation
requirements