Quick Guide
Table Of Contents
- Safety informations
- Preparation
- Checklist
- Prepare to install the oven
- Location requirements
- Product dimensions - single ovens (NV51K7770S, NV51K6650S)
- Product dimensions - single oven (NV51*5***S*)
- Cabinet dimensions - single ovens
- Product dimensions - double ovens (NV51K7770D, NV51K6650D)
- Product dimensions - double oven (NV51*5***D*)
- Cabinet dimensions - double ovens
- Installation instructions
- Self-diagnosis
- Información sobre seguridad
- Preparación
- Lista de verificación
- Preparación para instalar el horno
- Requisitos de ubicación
- Dimensiones del producto: hornos simples (NV51K7770S, NV51K6650S)
- Dimensiones del producto: horno simple (NV51*5***S*)
- Dimensiones del gabinete: hornos simples
- Dimensiones del producto: hornos dobles (NV51K7770D, NV51K6650D)
- Dimensiones del producto: horno doble (NV51*5***D*)
- Dimensiones del gabinete: hornos dobles
- Instrucciones de instalación
- Autodiagnóstico
- Consignes de sécurité
- Préparation
- Liste de contrôle
- Préparation avant l'installation du four
- Conditions d'emplacement
- Dimensions de l'appareil (fours simples - NV51K7770S, NV51K6650S)
- Dimensions de l'appareil (four simple - NV51*5***S*)
- Dimensions du meuble (fours simples)
- Dimensions de l'appareil (fours doubles - NV51K7770D, NV51K6650D)
- Dimensions de l'appareil (four double - NV51*5***D*)
- Dimensions du meuble (fours doubles)
- Consignes d'installation
- Auto-diagnostic
English 9
Preparation
If codes permit and a separate ground wire is used, it is recommended that a
qualied electrical installer determine that the ground path and the wire gauge are
in accordance with local codes.
Check with a qualied electrical installer if you are not sure the oven is properly
grounded.
This oven must be connected to a grounded-metal permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA
Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all
local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of electrical connection
you will be using and follow the instructions provided in this manual.
• Oven must be connected to the proper electrical voltage and frequency as
specied on the model/serial/rating plate. The model/serial/rating plate is
located on the bottom left side of the trim. See the following illustrations.
A
A
Single Oven
A. Model/serial/rating plate
Double Oven
A. Model/serial/rating plate
• A circuit breaker is recommended.
• Use the chart below to determine the minimum recommended dedicated
circuit protection.
KW Rating (240 V) KW Rating (208 V)
Recommended Circuit
Size (Dedicated)
≤4.8 KW ≤4.1 KW 20 Amp
4.9 KW - 7.5 KW 4.3 KW - 6.2 KW 30 Amp
7.3 KW - 9.6 KW 6.3 KW - 8.3 KW 40 Amp
9.7 KW - 12.0 KW 8.4 KW - 10.4 KW 50 Amp
• Connect directly to the circuit breaker box (or fused disconnect) through
exible, armored or nonmetallic sheathed, copper cable (with grounding wire).
See “Electrical Connection” section.