User Manual
E-8
Connecting the cable
When you install the unit, make first refrigerant connections and then elec-
trical connections. Connect the air conditioner to grounding system before
performing the electrical connection. If unit is uninstalled first disconnect
electrical cables, then refrigerant connections.
1
Extend the assembly cable if necessary.
CAUTION
Do not connect two or more different cables to extend the
length. It may cause fire.
2
Open the front grille.
3
Remove the screw securing the connector cover.
4
Pass the assembly cable through the rear of the indoor unit and connect the
assembly cable to terminals
. (Refer to the picture in page 9.)
Note
Each wire is labeled with the corresponding terminal number.
5
Pass the other end of the cable through the 65mm hole in the wall.
6
Close the connector cover by tightening the screw carefully.
7
Close the front grille.
8
Remove the terminal board cover on the side of the outdoor unit.
Connecting the Assembly Cable
Screw
Torque(kgf
.
cm)
Unfasten Torque Tighten Torque
M4 17~30 25~40
M5 20~35 30~50
INSTALLING THE AIR CONDTIONER