Safety Precautions This installation manual describes how to install the DMS. For installation of other optional accessories, refer to the appropriate installation manual. WARNING CAUTION Read carefully this installation manual before installation and check if the DMS is installed correctly after installation. Do not attempt to install or repair this DMS by yourself. This DMS contains no user-serviceable parts. Always consult authorized service personnel for repairs.
ENGLISH Contents SAFETY PRECAUTIONS ..................................................................... BEFORE INSTALLING THE DMS ...................................................... ACCESSORIES ..................................................................................... PRODUCT DESIGN ............................................................................ PRODUCT DIMENSIONS ................................................................... SYSTEM ARCHITECTURE ..................
Before installing the DMS(Data Management Server) The following items need to be prepared before installation. WARNING • Only static IP must be used for the DMS. (Public IP or private IP) The DMS is a server and only static IP must be used. To access the DMS through the internet or with SNET series, the DMS address, which is the IP address, must be known. A static IP service from an internet service provider must be used if xDSL (ADSL, VDSL) is being used for internet connection.
Accessories Cable Tie (2) Cable Clamp(3) Rubber Hook(4) User's manual(1) Installation manual(1) M4X16 Screw(5) ENGLISH DMS(1) Caution The DMS must be installed by a trained installer. Ensure the main power is turned off before installing the DMS. The power cable and the communication cable must be installed according to the national electrical wiring regulations. (VCTF 2C x 0.75mm2 must be used for the communication and power cables) Ensure the cables are out of user’s reach.
Product Dimensions 8 219 135 8 28 Unit : mm 130 135 60 30 20 150 Serial Port Power Input LAN Port 101010 37 60 Reset Button Installation Method Fix the provided screws to the wall and use the four holes on the back of the DMS to hang the DMS on the wall. E-6 MIM-D00_IM_E_29919-1.
ENGLISH System Architecture S-NET 3 DMS * HUB Centralized Controller Transmitter Transmitter Centralized Controller Network related equipments to be purchased separately SIM I/M Transmitter Power related equipments to be purchased separately * Power meter Connect one power meter to N number of outdoor units. Make sure the power meter capacity is greater than the total capacity of the outdoor units. Note roducts with ‘*’ are not Samsung products and must be P purchased separately.
Compatible Devices No. Devices Model Note 1 All System indoor/outdoor units such as: DVM, DVMH models, Indoor Unit DVM PLUS, DVM PLUS ΙΙ/ΙΙΙ, Outdoor Unit MINI DVM, HOME DVM, CAC models - 2 Interface Module MIM-B04A(for DVM, DVM PLUS etc.) MIM-B13(for DVM PLUS ΙΙ etc.) MIM-B13A(for DVM PLUS ΙΙ, ΙΙΙ etc.) - 3 Centralized Controller MCM-A202 MCM-A202A - 4 SIM I/M MIM-B12 Needed for power distribution *5 Watt-hour Meter RS485 comm.
Installing the DMS ENGLISH Connecting the Centralized Controller The centralized controllers must be installed to control the indoor units. 1 Loosen the two screws on the bottom of the DMS front cover. 2 Hold the bottom two sides of the DMS and push upwards to slide open the cover. (Sliding type cover) 3 Connect the provided power cable to the power terminal. 4 Connect the C1, C2 communication cable from the centralized controller to the J1 terminal of the DMS.
Installing the DMS (Continued) Connecting the SIM I/M The SIM I/M must be used for the power distribution function. 1 Loosen the two screws on the bottom of the DMS front cover. 2 Hold the bottom two sides of the DMS and push upwards to slide open the cover. (Sliding type cover) 3 Connect the provided power cable to the power terminal. 4 Connect the C1,C2 communication cable from the SIM I/M to the J1 terminal of the DMS. (Communication will fail if the cable is notconnected properly.
Connect the LAN cable to the J6 terminal of the DMS. 6 Close the case cover after making sure the power cable is not pressed. 7 Assemble the cover as shown in the picture to avoid exposure of the stripped wires. ENGLISH 5 POWER CABLE Peak Power I/M communication cable LAN CABLE Caution Maximum 8 SIM I/Ms can be connected to one DMS. Maximum 8 power meters can be connected to one SIM I/M. Separate the power cable and the communication cable when installing the DMS.
Installing the DMS (Continued) DMS PCB Option Switches 1 Reset Switch (SW01) : Resets the DMS when the DMS stops operating. (Pressing the reset switch will delete all current data. The switch must only be operated by the installer.) 2 DIP Switch(SW3) : Used for setting the DI mode. Operate only when the DI port is used. SW03 Note Refer to the appendix (page 22~23) for how to install the DI external signal control. E-12 MIM-D00_IM_E_29919-1.
ENGLISH Using the DI external contact signal control (Optional) DIP Switch (SW03) : Use only for external contact signal control. Pattern DIP Switch 1 2 3 4 Control Details Pattern OFF OFF OFF OFF No response to the external contact signal control. (Factory default setting) 1 Used for emergency cases such fire.
DMS External Display 1 2 3 4 5 6 7 8 9 10 LED Status Display Power (Red) Power display. The power display is on when there’s a power input. Flickers every second if the CPU is operating normally. CPU Alive(Yellow) (The CPU is in waiting status and the CPU Alive display is off initially when powered up.) Linked (Green) Active (Green) Internet cable connection status display. The display is on when connected to the internet. Flickers during data transceive.
Setting the Computer Environment The following device and accessory is needed: ENGLISH 1 Computer with a LAN Card *Cross Cable or a HUB 2 Setting the computer environment. Must have Internet Explorer 6.0 or above installed. Please install the internet explorer 6.0 or above through Windows Update Must have JRE 1.3.1 or above installed JRE can be downloaded from http://java.sun.com/j2se or automatically by connecting to the DMS through the internet.
Setting the Computer Environment (Continued) 4 Setting the computer environment to access the DMS for the first time. All the environment of the DMS is set by connecting to the DMS. In order to access the DMS, the computer environment must be set as follow: Choose one of the two methods to access the DMS. The default IP setting of the DMS is 192.168.0.
ENGLISH Connect to the internet. Run the internet explorer and type in the following address. http://192.168.0.2 If the connection is successful, the following front page will load. The DMS will prompt for a user ID and a password as shown above. The factory default user setting is as follow: admin 1234 Type in the ID and the password and click on LOGIN. Change the user setting if needed for security reasons. E-17 MIM-D00_IM_E_29919-1.
Setting the Computer Environment (Continued) The following screen is displayed if the login is successful. Click on SYSTEM ENVIRONMENT. E-18 MIM-D00_IM_E_29919-1.
ENGLISH Click on the ‘Edit’ button to change the language settings. (Default:English) The system will start up automatically once the language is set. Click on the ‘Edit’ button to change the DMS network settings. The system will start up automatically once the settings are saved. Click on the ‘Edit’ button to change the time settings. Set the time for accurate error time logs and schedule controls. Click on the ‘Edit’ button to change the Operation mode of A/C Running.
Setting the Computer Environment (Continued) Tracking Click on the tracking button once the environment is set. The above screen will be displayed. Select either the group mode tracking or the room mode tracking. Group mode tracking: Control the indoor units according to the RMC address. Room mode tracking: - Control the indoor units according to the MAIN address of the indoor units. - Indoor unit MAIN address and the RMC address will be displayed. The message “Tracking...Please wait.
ENGLISH The following screen is display if tracking is successful. Click on the edit button to change the names of the indoor units and the centralized controllers. The basic settings for the internet control is set. Please refer to the user manual for detailed information on internet control. Note For detail instructions on Tracking, refer to user’s manual. E-21 MIM-D00_IM_E_29919-1.
Appendix DI/DO circuit (Optional) 5 DI-2 2 DO-2 4 External contact signal control (ON/OFF control of all the indoor units) DI-2 (Digital Input) External contact signal control (ON/OFF control of all the indoor units) DO-1 (Digital Output) Outputs 12V if at least one indoor unit is running. (External circuit may be built for display using the 12V output) Equivalent to the ‘A/C Running’ LED on the DMS external display. Outputs as the settings on the Operation mode of A/C Running LED.
ENGLISH DI(Digital Input) Circuitry (Optional) Pattern 2 (May be used for connection with a fire sensor) ��� Emergency Stop/Resume Operation ���� ���� No Connection Pattern 3 ��� Run/Stop A/C ���� Enable/Disable remote control ���� Pattern 4 (Pulse signal control) ��� Run ���� Stop ���� Note Refer to page 12~13 for PCB DIP s/w settings when using the DI external signal control. E-23 MIM-D00_IM_E_29919-1.
Appendix (Continued) Setting the IP Address 1 When using DSL connection 1) Using a private IP : used if the internet control is not needed and the DMS is controlled only from one place. Connecting the DMS and the controller 1:1 DMS SNET-i *Cross Cable Private IP : 192.168.0.2 Private IP : 192.168.0.1 Computer DMS *Cross Cable Private IP : 192.168.0.2 Private IP : 192.168.0.
ENGLISH 3 IP terms explanation Public IP Static IP Dynamic IP Private IP Static IP Dynamic IP The DMS requires an IP address to be connected to the internet and to allow computers to access the DMS. Public IP Public IP addresses are IP addresses that are visible to the public.
Appendix (Continued) IP Setup Error 1 Initial connection error (occurs only when using a private IP) A number of DMS’ are connected on the same network The default factory IP setting of all the DMS’ are the same and when they are connected on the same network, the IP address of the DMS’ will collide. Please set the network environment of the DMS one at a time and connect all the DMS’ once all the IP addresses are set differently. Computer DMS 1 Initial IP : 192.168.0.
Installation Errors 1 Check the centralized controller and transmitter models. 2 Check the communication status between the centralized controller and the transmitter. Devices If the communication is normal Centralized The indoor units are controlled Controller according to the on/off buttons ‘U’ is displayed on the right side of the 7-segment display Transmitter ENGLISH Check points when tracking fails and the installation information of the indoor and outdoor units are not available.
MIM-D00_IM_E_29919-1.