Programming instructions

LD-14304-7
7. Timing Characteristics of input signals
Timing diagrams of input signal are shown in Fig.2.
7-1. Timing characteristics
Parameter Symbol Min. Typ. Max. Unit Remark
Clock Frequency 1/Tc
40.0 42.0 MHz
High time Tch 6
--
ns
Low time Tcl 6
--
ns
Duty ratio Th/T405060%
Data Setup time Tds 3
--
ns
Hold time Tdh 5
--
ns
Cycle TH 20.8 26.4
-μ
s
832 1056
clock
Horizontal
sync. signal
Pulse width THp 2 128 200 clock
Cycle TV 628 666 798 line
Vertical
sync. signal
Pulse width TVp 2 4 6 line
Horizontal display period THd 800 800 800 clock
Hsync-Clock phase difference THc 0
Tc-10 ns
Hsync-Vsync phase difference TVh 0
TH-THp ns
Vertical data start position TVs 23 23 23 line
Note) In case of lower frequency, the deterioration of display quality, flicker etc.,may be occurred.
7-2. Horizontal display position
The horizontal display position is determined by ENAB signal and the input data corresponding to the
rising edge of ENAB signal is displayed at the left end of the active area.
Parameter symbol Min. Typ. Max. Unit Remark
Enable signal Setup time Tes 5
Tc-10 ns
Pulse width Tep 2 800 TH-10 clock
Hsync-Enable signal phase difference THe 58 88 170 clock
Note) When ENAB is fixed "Low", the display starts from the data of C88(clock) as shown in Fig.2.
7-3. Vertical display position
The vertical display position, TVs is fixed “23” (line).
7-4. Input Data Signals and Display Position on the screen
D1,DH1
D1,DH2
D1,DH3
D2,DH2
D2,DH1
D3,DH1
D800,DH1
D800,DH600
D1,DH600
R
G B
Dis
p
la
y
p
osition of in
p
ut data
UP
05-Oct-2005