Programming instructions
RFI GLOBAL SERVICES LTD TEST REPORT
S.No. RFI/EMCE1/RP47590JD01A
Page 23 of 34
Issue Date: 04 October 2005
Test of: Psion Teklogix.
8530 Venicle Mount Computer.
To: 95/54/EC: 1995
ESA Approval Annex VII and Annex VIII, Emissions
9.2. Radiated Broad Band Emissions: Annex VII.
These measurements were performed in accordance with the standard, against appropriate limits for
a quasi peak detector.
All measurements were performed with an antenna height of 1.15 m and a measurement distance of
1.0 m (measured from the table edge to the nearest point of the measuring antenna) using a
measuring receiver incorporating a quasi peak detector.
The frequencies to be measured were determined by the spot frequencies given in the specification
and from the spurious emissions observed during the pre-scan stage of the narrowband emissions
test.
For the main (final) measurements the EUT was arranged on a 1.0m high non-conducting table, (this
table may or may not have an earthed metallic ground plane, depending on the earthing requirements
of the EUT) on an open area test site, as detailed in the specification.
All measurements on the open area test site were performed with a broadband antenna.
The test equipment settings for radiated broadband emissions measurements were as follows:
Receiver Function Final Measurements
Detector Type: Quasi Peak
Bandwidth: 120 kHz
Amplitude Range: 20 dB
Measurement Time: >1 s
Observation Time: >15 s
05-Oct-2005