Programming instructions
RFI GLOBAL SERVICES LTD TEST REPORT
S.No. RFI/EMCE1/RP47590JD01A
Page 19 of 34
Issue Date: 04 October 2005
Test of: Psion Teklogix.
8530 Venicle Mount Computer.
To: 95/54/EC: 1995
ESA Approval Annex VII and Annex VIII, Emissions
7.2.4. Radiated Broadband Emissions - Electric Field Strength Measurements
(Frequency Range: 30 to 1000 MHz): 24V
7.2.4.1. Plots of the initial scans can be found in appendix 4.
7.2.4.2. The following table lists frequencies at which emissions were measured using a quasi peak
detector, at a test distance of 1 metre (results incorporate antenna factors and cable losses):
Results:
Frequency
(MHz)
Line Quasi Peak
Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Note(s) Result
45.000 Vert. 12.70 59.60 46.90 - Complied
45.000 Horiz. 12.70 59.60 46.90 - Complied
65.000 Vert. 12.60 55.60 43.00 - Complied
65.000 Horiz. 14.20 55.60 41.40 - Complied
85.000 Vert. 14.10 54.80 40.70 - Complied
85.000 Horiz. 11.70 54.70 43.10 - Complied
120.000 Vert. 16.70 57.10 40.40 - Complied
120.000 Horiz. 18.60 57.10 38.50 - Complied
150.000 Vert. 17.00 58.60 41.60 - Complied
150.000 Horiz. 17.00 58.60 41.60 - Complied
190.000 Vert. 20.70 60.10 39.40 - Complied
190.000 Horiz. 20.90 60.10 39.20 - Complied
230.000 Vert. 40.10 61.40 21.30 - Complied
230.000 Horiz. 19.10 61.40 42.30 - Complied
280.000 Vert. 18.30 62.70 44.40 - Complied
280.000 Horiz. 17.60 62.70 45.10 - Complied
380.000 Vert. 21.70 64.70 43.00 - Complied
380.000 Horiz. 20.30 64.70 44.40 - Complied
450.000 Vert. 34.70 65.00 30.30 - Complied
450.000 Horiz. 22.80 65.00 42.20 - Complied
600.000 Vert. 25.30 65.00 39.70 - Complied
600.000 Horiz. 25.40 65.00 39.60 - Complied
750.000 Vert. 28.10 65.00 36.90 - Complied
750.000 Horiz. 28.50 65.00 36.50 - Complied
05-Oct-2005