Programming instructions
RFI GLOBAL SERVICES LTD TEST REPORT
S.No. RFI/EMCE1/RP47590JD01A
Page 18 of 34
Issue Date: 04 October 2005
Test of: Psion Teklogix.
8530 Venicle Mount Computer.
To: 95/54/EC: 1995
ESA Approval Annex VII and Annex VIII, Emissions
Radiated Narrowband Emissions - Electric Field Strength Measurements
(Frequency Range: 30 to 1000 MHz): 24V (Continued)
Frequency
(MHz)
Line Peak Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Note(s) Result
900.000 Vert. 32.20 55.00 22.80 - Complied
900.000 Horiz. 32.80 55.00 22.20 - Complied
359.973 Vert. 46.00 54.30 18.30 - Complied
359.973 Horiz. 38.40 54.30 18.90 - Complied
461.247 Vert. N/A 55.00 N/A 2 Complied
461.247 Horiz. N/A 55.00 N/A 2 Complied
538.034 Vert. 42.10 55.00 12.90 - Complied
538.034 Horiz. 31.40 55.00 23.60 - Complied
926.800 Vert. 49.90 55.00 5.10 1 Complied
926.800 Horiz. 52.00 55.00 3.00 1 Complied
Note(s):
1. The measured result is within the test standard limit by a margin less than the measurement uncertainty; it
is therefore not possible to state compliance based on the 95% level of confidence. However, the result
indicates that compliance is more probable than non-compliance.
2. This emission was identified as being the radio transmission from the EUT and was therefore an intentional
transmission not covered by the requirements of the specification.
05-Oct-2005