Programming instructions

RFI GLOBAL SERVICES LTD TEST REPORT
S.No. RFI/EMCE1/RP47590JD01A
Page 16 of 34
Issue Date: 04 October 2005
Test of: Psion Teklogix.
8530 Venicle Mount Computer.
To: 95/54/EC: 1995
ESA Approval Annex VII and Annex VIII, Emissions
Radiated Broadband Emissions - Electric Field Strength Measurements
(Frequency Range: 30 to 1000 MHz) 12V (Complied)
Frequency
(MHz)
Line Quasi Peak
Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Note(s) Result
527.163 Vert. 35.60 65.00 29.40 - Complied
527.163 Horiz. 30.20 65.00 34.80 - Complied
600.000 Vert. 25.30 65.00 39.70 - Complied
600.000 Horiz. 25.60 65.00 39.40 - Complied
750.000 Vert. 28.10 65.00 36.90 - Complied
750.000 Horiz. 28.20 65.00 36.80 - Complied
900.000 Vert. 31.30 65.00 33.70 - Complied
900.000 Horiz. 31.20 65.00 33.80 - Complied
Note(s):
1. This emission was identified as being the radio transmission from the EUT and was therefore an intentional
transmission not covered by the requirements of the specification.
05-Oct-2005