Programming instructions
RFI GLOBAL SERVICES LTD TEST REPORT
S.No. RFI/EMCE1/RP47590JD01A
Page 15 of 34
Issue Date: 04 October 2005
Test of: Psion Teklogix.
8530 Venicle Mount Computer.
To: 95/54/EC: 1995
ESA Approval Annex VII and Annex VIII, Emissions
7.2.2. Radiated Broadband Emissions - Electric Field Strength Measurements
(Frequency Range: 30 to 1000 MHz): 12V
7.2.2.1. Plots of the initial scans can be found in appendix 4.
7.2.2.2. The following table lists frequencies at which emissions were measured using a quasi peak
detector, at a test distance of 1 metre (results incorporate antenna factors and cable losses):
Results:
Frequency
(MHz)
Line Quasi Peak
Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Note(s) Result
45.000 Vert. 14.60 59.50 44.90 - Complied
45.000 Horiz. 12.10 59.50 47.40 - Complied
65.000 Vert. 15.70 53.05 37.35 - Complied
65.000 Horiz. 13.50 53.05 39.55 - Complied
87.000 Vert. 11.80 54.97 43.17 - Complied
87.000 Horiz. 10.90 54.97 44.07 - Complied
120.000 Vert. 16.80 57.08 40.28 - Complied
120.000 Horiz. 16.60 57.08 40.48 - Complied
150.000 Vert. 17.70 58.55 40.85 - Complied
150.000 Horiz. 20.40 58.55 58.15 - Complied
190.000 Vert. 20.90 60.10 39.20 - Complied
190.000 Horiz. 20.30 60.10 39.80 - Complied
230.000 Vert. 18.00 61.36 43.36 - Complied
230.000 Horiz. 18.80 61.36 45.56 - Complied
280.000 Vert. 18.00 62.60 44.60 - Complied
280.000 Horiz. 17.20 62.60 45.40 - Complied
335.480 Vert. 31.30 63.84 32.54 - Complied
335.480 Horiz. 31.90 63.84 31.94 - Complied
380.000 Vert. 22.00 64.60 42.60 - Complied
380.000 Horiz. 19.90 64.60 45.60 - Complied
430.000 Vert. 31.40 65.00 23.60 - Complied
430.000 Horiz. 23.10 65.00 41.90 - Complied
461.013 Vert. N/A N/A N/A 1 Complied
461.013 Horiz. N/A N/A N/A 1 Complied
05-Oct-2005