Programming instructions

RFI GLOBAL SERVICES LTD TEST REPORT
S.No. RFI/EMCE1/RP47590JD01A
Page 13 of 34
Issue Date: 04 October 2005
Test of: Psion Teklogix.
8530 Venicle Mount Computer.
To: 95/54/EC: 1995
ESA Approval Annex VII and Annex VIII, Emissions
7.2. Test Results
7.2.1. Radiated Narrowband Emissions - Electric Field Strength Measurements
(Frequency Range: 30 to 1000 MHz): 12V
7.2.1.1. Plots of the initial scans can be found in appendix 4.
7.2.1.2. The following table lists frequencies at which emissions were measured using a peak or an
average detector, at a test distance of 1 metre (results incorporate antenna factors and cable losses):
Results:
Frequency
(MHz)
Line Peak Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Note(s) Result
45.000 Vert. 16.90 49.50 32.60 - Complied
45.000 Horiz. 13.50 49.50 36.00 - Complied
65.000 Vert. 17.60 43.05 25.45 - Complied
65.000 Horiz. 19.70 43.05 23.35 - Complied
87.000 Vert. 14.70 44.97 30.27 - Complied
87.000 Horiz. 14.70 44.97 30.27 - Complied
120.000 Vert. 19.80 47.08 27.28 - Complied
120.000 Horiz. 18.10 47.08 28.98 - Complied
150.000 Vert. 18.90 48.55 29.65 - Complied
150.000 Horiz. 21.90 48.55 26.65 - Complied
190.000 Vert. 22.30 50.10 27.80 - Complied
190.000 Horiz. 20.60 50.10 29.80 - Complied
230.000 Vert. 20.00 51.36 31.36 - Complied
230.000 Horiz. 22.10 51.36 29.26 - Complied
280.000 Vert. 20.70 52.60 31.90 - Complied
280.000 Horiz. 18.50 52.60 34.10 - Complied
335.480 Vert. 32.70 53.84 21.14 - Complied
335.480 Horiz. 33.10 53.84 20.74 - Complied
380.000 Vert. 27.60 54.60 27.00 - Complied
380.000 Horiz. 20.60 54.60 34.00 - Complied
430.000 Vert. 35.60 55.00 19.40 - Complied
430.000 Horiz. 28.10 55.00 26.90 - Complied
461.013 Vert. N/A N/A N/A 1 Complied
461.013 Horiz. N/A N/A N/A 1 Complied
05-Oct-2005