13Reliability test items
No. Test item Conditions
1 High temperature
& high humidity storage test
Ta= 50 ; 95%RH 240h
(No condensation)
2 High temperature storage test
Ta= 70 240h
3 Low temperature storage test
Ta= -35 240h
4 High temperature
& high humidity operation test
Ta= 40 ; 95%RH 240h
(No condensation)
5 High temperature operation test
Ta= 65 240h
6 Low temperature operation test
Ta= -10 240h
7 Vibration test
(non- operating)
Frequency: 1057Hz/Vibration width (one side):0.075mm
: 58500Hz/Gravity:9.8m/s
2
Sweep time : 11 minutes
Test period : 3 hours
(1 hour for each direction of X,Y,Z)
8 Shock test
(non- operating)
Max. gravity : 490m/s
2
Pulse width : 11ms, half sine wave
Direction : ±X,±Y,±Z
once for each direction.
Result Evaluation Criteria
Under the display quality test conditions with normal operation state, these shall be no change
which may affect practical display function.
14Others
1) Lot No Label:
LQ104S1DG21
24 XXXXXX_
MADE IN
J
APAN
Model No.
Lot No.
2) Adjusting volume have been set optimally before shipment, so do not change any adjusted value.
If adjusted value is changed, the specification may not be satisfied.
3) Disassembling the module can cause permanent damage and should be strictly avoided.
4) Please be careful since image retention may occur when a fixed pattern is displayed for a long time.
5) Do not use LCD module in the atmosphere of corrosive gases, such as sulfide gas or chlorine gases.
Polarizer may deteriorated or cause chemical reaction that can lead to short circuits at the terminal Points.
Do not use the material, which compounds contain sulfide or chlorine articles in the vicinity of LCD module.
At high temperature, these compounds produce corrosive gases.
6) If any problem occurs in relation to the description of this specification , it shall be resolved through discussion
with spirit of cooperation.