Chilled Liquid Setpoint Cooling Setpoints
SETPOINTS DEF LO HI
LOCAL COOLING SETPOINT = XX.X °F
This message displays the programmed cooling setpoint
at the time of the fault.
SETPOINTS DEF LO HI
LOCAL CONTROL RANGE = +/- X.X °F
This message displays the programmed Control Range at
the time of the fault.
Remote Setpoint and Range
SETPOINTS REMOTE SETPOINT = XX.X °F
REMOTE CONTROL RANGE = +/- X.X °F
This message displays the remote setpoint and Control
Range at the time of the fault.
Maximum Remote Temperature Setpoint
SETPOINTS DEF LO HI
MAXIMUM REMOTE TEMP RESET = XX °F
This message displays the maximum remote reset
programmed at the time of the fault.
Options
Display Language
OPTIONS DISPLAY LANGUAGE
< > ENGLISH
This message displays the language selected at the time
of the fault.
Chilled Liquid Cooling Mode
OPTIONS CHILLED LIQUID COOLING MODE
< > WATER COOLING
OPTIONS CHILLED LIQUID COOLING MODE
< > GLYCOL COOLING
This message displays the chilled liquid temperature
mode (water or glycol) selected at the time of the fault.
Local / Remote Control Mode
OPTIONS LOCAL / REMOTE CONTROL MODE
< > LOCAL CONTROL
This message indicates whether Local or Remote Control
Mode was selected at the time of the fault.
When Remote Control Mode is selected, control of the
Chilled Liquid Setpoint is from a remote device such as
an ISN/BAS controller.
Display Units Mode
OPTIONS DISPLAY UNITS
< > SI
OPTIONS DISPLAY UNITS
< > IMPERIAL
This message indicates whether SI (°C, barg) or Imperial
units (°F, PSIG) was selected at the time of the fault.
System Lead/Lag Control Mode
OPTIONS LEAD / LAG CONTROL MODE
< > AUTOMATIC
This message indicates the type of lead lag control
selected at the time of the fault. Three choices are
available: Automatic, Sys 1 Lead, Sys 2 Lead.
The default mode will be AUTOMATIC.
Remote Temperature Reset
OPTIONS REMOTE TEMP RESET INPUT
< > DISABLED
This message indicates whether temperature reset was
active or disabled at the chiller keypad at the time of the
fault and if active, the type of reset signal selected.
If the option is not factory enabled, the option will not
appear.
Remote Current Reset
OPTIONS REMOTE CURRENT LIMIT INPUT
< > DISABLED
This message indicates whether remote current reset was
active or disabled at the chiller keypad at the time of the
fault and if active, the type of reset signal selected.
If the option is not factory enabled, the option will not
appear.
Remote Sound Limit Selection
OPTIONS REMOTE SOUND LIMIT INPUT
< > DISABLED
This message indicates whether remote sound limit was
active or disabled at the chiller keypad at the time of the
fault and if active, the type of reset signal selected.
If the option is not factory enabled, the option will not
appear.