Specifications
- 29 -
4-1-3 E-27,E-29, E-2b, E-71
YES
NO
NO
YES
NO
YES
NO
Sensor Open Error (E-27, E-29, E-2b, E-71)
Perform the operation again and check if it
 is working properly.
: Check if the sensor housing 
 is inserted into the connector 
 of the main PCB.
The sensor is out of order.
Is the sensor disconnected?
Is the sensor wire
connected properly?
Does the voltage change
as the humidity, temperature
and weight change?
Replace the sensor.
: Check if the sensor wire is damaged, if the
 housing is loose and if the sensor and the
 wire are properly connected.
 : Check if the voltage of the GND and sensor
 changes using a digital multi-meter
 by forcefully changing the humidity, temperature
 and weight.
Connect the sensor.
Connect the 
wire properly.
S/W Error
After Power -> On, does 
the symptom continue?
Replace the PCB.