OWNER’S INSTRUCTIONS AWT12PHHEA AWT19PHHEB AWT24PHHEC Window-type Room Air Conditioner ( Cool ) E PE DB98-21815A
AQ07S2GE IB_E_15110 04/2/2 15:35 Page 2 Safety Precautions The following safety precautions must be taken when using your air conditioner. WARNING DURING OPERATION Risk of electric shock. • Can cause injury or death. • Disconnect all remote electric power supplies before servicing, installing or cleaning. • This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
AWT18PHHBA_E_17028 04/2/23 10:37 Page 3 Contents PREPARING YOUR AIR CONDITIONER ■ ■ ■ ■ ■ Safety Precautions ......................................................................................... Air Conditioning Unit - Main Parts, Buttons and Display ............................... Remote Control - Buttons .............................................................................. Getting Started ...............................................................................................
Air Conditioning Unit - Main Parts, Buttons and Display The design and shape are subject to change according to the model. Inner air flow blades (right/left orientation) Air inlet (Inside) Outer air flow blades (up/down orientation) Air filter (Inside) Air inlet (Outside) Ventilation lever Power Cable AWT18***** AWT24***** AWT12***** Power plug (The type of the power plug may differ according to the type of local power supply.
AWT18PHHBA_E_17028 04/2/23 10:37 Page 5 Remote Control - Buttons Timer setting button Sleep timer setting button Operating mode selection buttons Temperature adjustment buttons Fan speed adjustment buttons Energy Saver button Air flow blade swing button On/Off button E-5
Getting Started You have just purchased a window-type room air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contain valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit’s functions. This Owner’s Instructions is just for using your air conditioner correctly. Thus, the illustrations shown in this manual may not exactly match your air conditioners.
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when: ◆ You purchase the air conditioner ◆ The remote control does not work correctly ☛ Use two AAA, LR03 1.5 V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used. 1 Push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it.
Cooling Your Room Remote Control Control Panel You must select the Cool mode if you wish to lower the temperature in your room.You can also set the fan speed. 1 If necessary, press the (On/Off ) button. The air conditioner starts up in the Cool mode. Result: The unit beeps twice. The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: Plugged in Stopped It will start up automatically after about three minutes.
AiringYour Room If the atmosphere in your room is stale, you can air it using the Fan feature and if necessary, evacuate the stale air outside. 1 If you wish to evacuate stale air outside, push the ventilation lever on the front of the unit to the right and the open position ( ). The air inside the room circulates and stale air is evacuated Result: outside. Otherwise, push the ventilation lever to the left and the closed position ( ). Result: The air simply circulates inside the room.
Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. Remote Control Control Panel 1 If necessary, press the Result: (On/Off) button. The air conditioner starts up in the Cool mode. The unit beeps.
Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room, you can adjust the orientation of the inner air flow blades on the right-hand side of the unit, thus increasing the efficiency of the air conditioner. 1 Press the Result: (or Remote Control Control Panel on the unit) button on the remote control. The inner blades swing automatically left and right. In the Energy Saving mode, the blades may stop when the compressor is off.
Setting the On Timer Remote Control Control Panel The On Timer enables you to switch on the air conditioner automatically after a given period time.You can set the period of time from 1 hour to 24 hours. You can select the On Timer only when the air conditioner is off. 1 Check that the air conditioner has been switched off; if necessary, press the (On/Off) button. 2 Set the operating time by pressing: on the remote control. or on the unit one or more times.
Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. Y ou can set the period of time from 1 hour to 24 hours. You can select the Off Timer only when the air conditioner is on. 1 Check that the air conditioner has been switched on; if necessary, press the (On/Off) button. 2 Set the operating time by pressing: on the remote control. or on the unit one or more times.
Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of 8 hours. Remote Control Control Panel If you wish to switch the unit off at a specific time, refer to page 12. 1 Make sure that you have selected either COOL mode. 2 Press the or Press the Result: Cooling button on the remote control button on the unit until the indicator lights up. Each time you press a butoon, the unit beeps.
Selecting Energy Saving Mode If you wish to save Energy when using your air conditioner, select the Energy Saving mode with the Energy Saver button. 1 Remote Control Control Panel To select the Energy Saving mode, press the Energy Saver button on the remote control or unit one or more times until the Energy Saver indicator lights up. Result: The fan and compressor cycle on and off together. The fan will continue to run for a short time after the compressor cycles off.
Cleaning Your Air Conditioner Be sure to clean the air filter periodically two weeks to maintain the air conditioner in the best condition for a long period of time. IMPORTANT When cleaning the air conditioner, turn it off and pull out the power plug. 1 Hold the front grille handle, slightly pull it to the left side and open the front grille. The removal of the front grille makes it easier to clean the air conditioner. Open the grille as much as possible.
AWT18PHHBA_E_17028 04/2/23 10:37 Page 17 Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary service call. Problem Explanation/Solution The air conditioner does not operate at all ◆ ◆ ◆ Check that the circuit breaker used for the air conditioner has not been triggered. Check that the power cable is plugged into a wall socket and the socket is switched on, if necessary.
AWT18PHHBA_E_17028 04/2/23 10:37 Page 18 Technical Specifications Design and specifications are subject to change without notice.
AWT18PHHBA_E_17028 04/2/23 10:37 Page 19 Method of Installation Before installation, be sure to check the installation area or the air conditioner, and drain hose. Checkpoints prior to installation 1 Check the cabinet and front grille of the unit for any harmful defects such as scratches. 2 Be sure to check the power supply. - Refer to the specifications on the label attached to the unit.
AWT18PHHBA_E_17028 04/2/23 10:37 Page 20 Method of Installation (cont.) Rear Rubber cap Installation of the Drain Tube Fix the drain tube as shown in the figure. Gasket Drain Tube Screws(2EA) Installation of the Drain Pan The procedure for installing the drain pan should be determined by the condition of the installing area. ◆ In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner.
Method of Installation (cont.) 4 Remove the chassis from the cabinet. Drain Pan Rear 5 Remove the rubber cap inserted into the basepan. Rubber cap Drain Hose 6 Fix the drain pan as shown in the figure, and then connect the drain hose. (You can use any commercially-available drain hose.) Screw Bottom-Side View with Drain Pan and Hose in Place 7 Install the cabinet at the specified area after installing the drain pan, and then re-assemble it in the original condition.
THIS AIR CONDITIONER IS MANUFACTURED BY: