AS12BGC Series AS18BGC Series AS24BGC Series AS12BBD Series AS18BBD Series AS24BBD Series AS12TC Series AS18TC Series AS18ED Series AS24ED Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register E DB98-32985A(2) Boracay_AS12B_SPI@_IBIM_32985A_E.
Features of your new air conditioner Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. Beat the heat with your own air conditioner this summer.
USING PARTS Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.
Safety precautions FOR POWER SUPPLY WARNING Plug the power plug into the wall socket in the right direction so that the cord runs towards the floor. If you plug the power plug into the socket in the opposite direction, the electric wires within the cable may be damaged and this may result in electric shock or fire. When the appliance or power plug or power cord is damaged, contact your nearest service center. Plug the power plug into the wall socket firmly.
FOR USING WARNING If any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center. Failing to do so may result in electric shock or fire. Do not attempt to repair, disassemble, or modify the appliance yourself. Do not use any fuse (such as cooper, steel wire, etc.)other than the standard fuse.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. Mode Indoor temperature Outdoor temperature Indoor humidity Cooling 16˚C~30˚C 21˚C~52˚C Relative humidity 80% or less Dry 18˚C~30˚C 21˚C~52˚C - If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
Checking the name of the parts Your air conditioner may slightly look different from illustration shown above depending on your model.
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display. Remote controller buttons Remote controller display Power S-Plasma ion Mode Turn on/off the air conditioner. Set the S-Plasma ion function on/off.
Remote controller display Quiet indicator Turbo indicator S-Plasma ion indicator Smart Saver indicator d'light Cool indicator 2ndF indicator Set temperature indicator On Timer indicator Off Timer indicator indicator This display doesn't have any function Operation mode indicator Low battery indicator Transmit indicator Air swing indicator Fan speed indicator Auto (Turbo) Low Medium High • Make sure that the water does not get to the remote controller.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature. Cool In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.
Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry and Fan. Press the button to set the desired fan speed. Auto (Auto) Cool (Auto), Dry (Auto) Fan (Low), (Low), (Med), (Med), (High) (High) ※ Fan speed can be adjusted as per above table in different Modes. Press the button to adjust the temperature.
Adjusting the air flow direction Air flow can be directed to your desired position. Vertical air flow Air flow blades move up and down. Press the Air swing button on the remote controller. Air swing indicator will be on and air flow blades move up and down continuously to circulate the air. Press the Air swing button on the remote controller again, to keep the air flow direction in a constant position.
Bio Sleep mode For a comfortable sleep, the air conditioner will operate it Fall asleep Sound sleep Wake up from mode. When the air conditioner is on and in cool mode 1. Press the Bio Sleep button on the remote controller. indicator appears and Off timer indicator starts blinking on the remote controller display. 2. Press the Bio Sleep button to set the time. You can set the time in half hourly unit from 30 minutes ~ 3 hours and hour unit from 3 hours ~ 12 hours.
Setting the On/Off timer You can set the air conditioner to turn on/off automatically at desired time. Setting On timer while the air conditioner is off / Off timer while the air conditioner is on Setting On timer 1. Press the On Timer/Off Timer button. On/Off timer indicator will blink on the remote controller display. 2. Press the Time Up or Time Down button to set the time. You can set the time in half hourly unit from 30 minutes ~ 3 hours and hour unit from 3 hours ~ 24 hours.
Combining On Timer and Off Timer If the air conditioner is on If the air conditioner is off Preset time on On timer is longer than Off timer Ex) On timer : 3 hours, Off timer : 1 hour - The air conditioner will operate the Off timer after 1 hour from the moment you have set the timer. Your air conditioner will turn on after 2 hours.
Using the Smart Saver function This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode. Press the Smart Saver button on the remote controller while the air conditioner is operating in Cool mode. Smart Saver indicator and air swing indicator appears automatically on the remote controller display. The air flow blades move up and down. If the current set temperature is lower than 24°C, it will automatically raise to 24°C.
Using the d'light Cool function The sensor in the indoor unit, which measures temperature and humidity in a room, keeps the room temperature in the most comfortable level by controlling the temperature and the fan speed automatically. Press the d'light Cool button on the remote controller while the air conditioner is operating in Cool mode. d'light Cool indicator and air swing indicator appears automatically on the remote controller display.
Cleaning the air conditioner • Make sure the power is turned off and unplugged from the wall socket when cleaning the air conditioner. Cleaning the indoor unit Wipe the surface of the unit with a slightly wet or dry cloth when needed. • Contact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled. • Do not clean the display using alkaline detergent.
Removing the Air filter AS***BGC, AS***BBD Grab the handle and lift it up. Then, pull the Air filter towards you and slide it down. Air filter AS***E**, AS***T** ※ Illustration may differ slightly depending on the models. Cleaning the air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Open the panel and put the Air filter out. Clean the Air filter with a vacuum cleaner or soft brush.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not work at all. • Check power status and then operate the air conditioner again. • Plug in or switch on the circuit breaker and then operate the air conditioner again. • Check if you have set the Off Timer. Operate the air conditioner again by pressing the Power button. The temperature adjustment is not working.
Troubleshooting PROBLEM SOLUTION Error is indicated. • When an indoor unit indicator blinks, contact the nearest service center. Noise is generated. • Depending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. It is normal. Water is dropping from the outdoor unit piping connection. • Water may be generated because of the temperature difference. It is normal. 22 Boracay_AS12B_SPI@_IBIM_32985A_E.
INSTALLATION PARTS ※ In this manual, you may find model names written in simplified forms as indicated in following table. Model Names Included Models 12 AS12BGC, AS12BBD, AS12TC 18 AS18BGC, AS18BBD, AS18TC, AS18ED 24 AS24BGC, AS24BBD, AS24ED Remark Grouping was done by series. Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.
Safety precautions Installing the unit IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport.
Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3m or more away from the TV or radio (to prevent the screen from being distorted or noise f
Choosing the installation location Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake Air outlet Air intake Air outlet , Air flow direction.
500 or more 600 or more 1500 or more 600 or more 300 or more 500 or more (Unit : mm) When the upper part of the outdoor unit and the air outlet is opposite the wall 300 or more When the walls are blocking front and the rear side of the outdoor units 300 or more When front and rear side of the outdoor unit is towards the wall 1500 or more 600 or more 3000 or more 3000 or more 200 or more • If installation is done in inappropriate space, unit may generate sound and cause bad effect o
Accessories Tools required for installation General Tools • Vacuum Pump(Backward flowing prevention) • Torque Wrench • Pipe Cutter • Reamer • Screw Driver • Spanner • Drill • Manifold Gauge • Pipe Bender • L Wrench • Stud Finder • Spirit Level • Measuring Tape Tools for test operations • Thermometer • Resistance Meter • Electroscope Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit.
Connecting the assembly cable Cable specification Model Interconnection cable AS12C 3G, Not less than 1.5mm² AS18C 3G, Not less than 2.5mm² AS12D 3G, Not less than 1.5mm² AS18D 3G, Not less than 1.5mm² AS24D 3G, Not less than 2.5mm² • Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥3mm. • For each model use specied cable only as written in below table.
Connecting the assembly cable 9. Connect the cables to the terminals as seen in the picture. • Each wire is labeled with the corresponding terminal number. Indoor unit AS12/18 AS24 Indoor unit Indoor unit N E E Outdoor unit Ground wire (Green/Yellow) E L E Ground wire (Green/Yellow) E Ground wire (Green/Yellow) E Outdoor unit E Ground wire (Green/Yellow) E Outdoor unit • End of the wire must be circular.
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
Purging the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flow out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1. Unscrew the caps at the end of each pipe. All inert gas exhausts from the indoor unit. • To prevent dirt or foreign substances from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the pipes.
5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Correct Inclined Damaged Surface Cracked Uneven Thickness 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Outer Diameter ø6.35 mm ø9.52 mm ø12.70 mm ø15.88 mm ø19.05 mm ø22.
Installing and connecting the drain hose of the indoor unit Drain hose installation 1. If necessary, connect the 2-meter extension drain hose to the drain hose. 2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield. 3. Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp. • If you do not use the other drain hose hole, block it with a rubber stopper. 4.
Purging the connected pipes The outdoor unit is loaded with sufficient R22 refrigerant. Do not vent R22 into atmosphere: it is a fluorinated greenhouse gas. You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as seen in the picture. • When installing, make sure there is no leakage.
Purging the connected pipes Adding Refrigerant Add refrigerant charge according to table below: If you use a pipe longer than 4m, ‘A’g of refrigerant R22 must be added for each extra meter. Model A 12 20 If you use a pipe shorter than 4m, 18 20 The purge time is normal. 24 25 Refer to the Service Manual for further details. • The remaining air in the Refrigeration cycle, which contains moisture, may cause malfunction on the compressor.
Fixing AA the indoor unit in place Perform the following work on the area where gas leak test was done priorly. After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. Insulation 1. To avoid condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. Pipes 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3.
Final Check and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1.
How to connect your extended power cables I tems to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Spec Crimping plier Connection sleeve (mm) Insulation tape Contraction tube (mm) MH-14 20xØ7.0(HxOD) Width 18mm 50xØ8.0(LxOD) Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already.
QUESTIONS OR COMMENTS? COUNTRY INDIA CALL 3030 8282 1800 110011 1800 3000 8282 OR VISIT US ONLINE AT www.samsung.com 42 Boracay_AS12B_SPI@_IBIM_32985A_E.