Features of your new air conditioner 2-step cooling 2-step cooling function will quickly cool the room to reach the set temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing.
Contents Preparation Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Checking before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.
FOR INSTALLATION 01 Preparation Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. This may result in electric shock or fire. Never install the outdoor unit in a location such as on a high external wall where it could fall.
Safety precautions FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. Failing to do so may result in electric shock or fire. FOR USING WARNING If the appliance is flooded, please contact your nearest service center. Failing to do so may result in electric shock or fire.
01 Preparation Do not touch the air flow blade with your hands or fingers during the heating operation. This may result in electric shock or burns. Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner. Take special care that children do not injure themselves by inserting their fingers into the product. Do not strike or pull the air conditioner with excessive force. This may result in fire, injury, or problems with the product.
Safety precautions FOR USING CAUTION Do not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances) Check that the installation frame of the outdoor unit is not broken at least once a year. Failing to do so may result in injury, death or property damage. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.
FOR CLEANING 01 Preparation This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. Mode Indoor temperature Outdoor temperature Indoor humidity Cooling 16 ˚C~32 ˚C -10 ˚C~46 ˚C Relative humidity 80% or less Heating 27 ˚C or less -15 ˚C~24 ˚C - Dry 18 ˚C~32 ˚C -10 ˚C~46 ˚C - ffIf the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model. Air filter 02 Basic function Main parts Air intake Air flow blade (up and down) Air flow blade (left and right) Display Power indicator Timer/Auto clean indicator Power button/ Remote controller receiver Single user indicator English-11 AR5000 ET_IB&IM_DB68-05220A_HP_EN.
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display.
Remote controller display Transmit indicator Operation mode indicator Set temperature/ Time (for Timer option) indicator 02 Basic function Low battery indicator Fan speed indicator good'sleep indicator Vertical air swing indicator Options indicator Settings indicator • M ake sure that the water does not get to the remote controller. • The following function are displayed on the remote controller display but not supported in this model.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto(2-Step Cooling or Heat ) In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature. • 2-Step Cooling mode sets the air conditioner to operate in Fast + Cool mode when set temperature is lower than indoor temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature.
Basic function button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat . Press the Press the 02 Basic function Press the button to adjust the temperature. Auto You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C. Cool You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
Adjusting the air flow direction This function will allow you to adjust the air flow direction vertically. Press the button to make air flow blades vertically. Vertical air flow ffTo keep the air flow direction in a constant direction, press the button again. The air flow blade(s) will stop the movement. If you adjust the vertical air flow blade manually, it may not close completely when you turn off the air conditioner.
Setting the On/Off timer Setting the On timer When the air conditioner is off; Cancel ffPress the Timer button select (On) press the set the timer to press the SET button. ffPress the Power ( ) button. or 03 Timer 1. Press the Timer button to select (On). -- (On) indicator will keep blinking and you can set the time. 2. Press the button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~24 hours.
Setting the On/Off timer Setting the Off timer When the air conditioner is on; 1. Press the Timer to select (Off). -- (Off) indicator will keep blinking and you can set the time. 2. Press the button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~24 hours. -- Time can be set from minimum 30 minutes to maximum 24 hours. 3. Press the SET button to complete the Off timer setting.
mode For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage. When the air conditioner is operating in Cool/Heat mode; 03 Timer 1. Press the Timer button to select ( ). -- ( ) indicator will keep blinking and you can set the time. 2. Press the button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~12 hours.
2-Step cooling function 2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature. When the air conditioner is operating in Cool mode; 1. Press the Options button. 2. Press the , or Options button until (2-Step) indicator starts to blink. 3.
Using the Fast function You can set the Fast function to provide fast and powerful cooling/heating . When the air conditioner is operating in Cool/Heat mode; 04 Options 1. Press the Options button. 2. Press the , or Options button until (Fast) indicator starts to blink. 3. Press the SET button to set the Fast function. -- (Fast) (Fast) indicator will be displayed on the remote controller display and Fast function will begin.
Using the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool/Heat mode. When the air conditioner is operating in Cool/Heat mode; 1. Press the Single user button. -- (Single user) indicator will be displayed on the remote controller display. Then will be displayed on the set temperature indicator part for few seconds and Single user function will begin. -- When the Single user function is on, vertical air swing will turn on automatically.
Using the Quiet function You can reduce the noise generated from an indoor unit during Cool/Heat mode. When the air conditioner is operating in Cool/Heat mode; Cancel 04 Options 1. Press the Options button. 2. Press the , or Options button until (Quiet) indicator starts to blink. 3. Press the SET button to set the Quiet function. -- (Quiet)(Quiet) indicator will be displayed on the remote controller display and Quiet function will begin.
Using the Auto clean function Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with clean air. When the air conditioner is operating; 1. Press the Settings button. 2. Press the , or Settings button until (Clean) indicator starts to blink. 3. Press the SET button to set the Auto clean function.
Cleaning the air conditioner CAUTION • Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner. 06 Others Cleaning the indoor unit ffClean the product with a tepid damp cloth. ffRemove the dust accumulated in the gap of the product with a soft brush. • C ontact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled. • Do not clean the display using alkaline detergent.
Cleaning the air conditioner Air filter Removing the Air filter There is a hole on the bottom right side of the filter. Put your finger in that hole to get a grip on the filter and slightly push it up to release the hooks from the bottom side. Then, pull it down to remove the filter from the main body. Cleaning the air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Remove the Air filter from the main body.
Reassembling the Air filter Air filter 06 Others 1. Put the filter on the main body and insert the hooks which are in the top of the Air filter into the the main body. 2. There’s one hook in both side of the filter, press the surface of the Air filter softly and get the hooks into the main body. 3. Press the bottom of the filter lightly to securely fix the main body. English-27 AR5000 ET_IB&IM_DB68-05220A_HP_EN.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. SOLUTION The air conditioner does not work at all. • Check power status and then operate the air conditioner again. • Plug in or switch on the circuit breaker and then operate the air conditioner again. • Ensure Isolator is switch on. • Check if you have set the Off Timer. Operate the air conditioner again by pressing the Power button.
Troubleshooting PROBLEM SOLUTION Fan speed adjustment is not working. • C heck if you have selected Auto/Dry/Fast/Comfort/ mode. In these mode, fan speed is set to Auto and you cannot adjust the fan speed. Remote controller is not working. • Check if your batteries are depleted. • Make sure nothing is blocking your remote controller sensor. • Check that there are strong lighting apparatus near the air conditioner.
Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment. • Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components. • Verify that the air conditioner is not installed in an easily accessible area.
Safety precautions After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user. Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries. To help prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5 m above the floor.
Outdoor Unit 07 INSTALLATION Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3 m or more away from the TV or radio (to prevent the screen
Choosing the installation location Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake Air outlet Air intake Air outlet , Air flow direction.
(Unit : mm) 500 or more 1500 or more 600 or more 300 or more When front and rear side of the outdoor unit is towards the wall 1500 or more 600 or more 3000 or more 3000 or more 07 INSTALLATION 600 or more 300 or more 500 or more When the upper part of the outdoor unit and the air outlet is opposite the wall 300 or more When the walls are blocking front and the rear side of the outdoor units 200 or more • I f installation is done in inappropriate space, unit may generate sound and
Accessories Accessories in the outdoor unit case 2-wire Assembly Cable (1) 3-wire Assembly Cable (2) Drain Plug (1) Rubber Leg (4) • T he flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • The assembly cable is optional. If it is not supplied, use the standard cable. • The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.
Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
Fixing the installation plate • S earch for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger. • Fix the installation plate without inclining to one side. • M ake sure that a wall can withstand the weight of the product. If you install the product in a place where it is not strong enough to withstand the product weight, the unit could fall and cause injury.
Removing the Cover panel (Before mounting the indoor unit) Number and location of the hooks Side hooks Center hook Center hooks Bottom hooks ffRemoving the hooks on the side ② 07 INSTALLATION The bottom panel fits the main body using the side, center, and bottom hooks as shown. Unlock the side hooks first, and then unlock the center and bottom hooks. Check the location of the hooks before removing the cover panel.
Connecting the assembly cable Cable specification Model Power cable Interconnection cable 09/12 3G1.5 mm² H07RN-F 3G1.0mm² H07RN-F 2x0.75mm² H05RN-F Type GL 20 A • C onnect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥3 mm. • Use shield cable (Category 5; less than 50pF/m) for noisy environmental site.
07 INSTALLATION 2 . Open the cover panel. 3 . Remove the screw securing the connector cover. 4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below) • Each wire is labeled with the corresponding terminal number. 5. 6. 7. 8. 9. Pass the other end of the cable through the 65 mm hole in the wall. Close the connector cover by tightening the screw carefully. Close the cover panel.
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
Assembling the hanger screw and guide 1. Cut out the knock-out piece according to the drain hose direction before fixing the indoor unit. 3. Use 2 screws to fix the indoor unit as shown in the picture. 07 INSTALLATION Left and right each has one knock-out piece 2. Fix the indoor unit on the wall. Pass the cables, pipes and hose through the hole which would be connected to the outdoor unit . Screw 4. Assemble the Guide into the position where the knock-out piece has been cut out before.
Cutting or extending the pipe 1. Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder). 2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90° with the side of the pipe (see below examples of correct and incorrect cut edges). Pipe cutter Oblique Rough Burr Pipe 3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.
Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65 mm hole drilled in the wall, check the followings: Wall The drain hose must NOT slant upwards. 5cm less The end of the drain hose must NOT be placed under water. The drain hose must not be bent.
Installing and connecting the drain hose of the indoor unit 40~45 mm Drain hose Extension drain hose Drain hose Extension drain hose 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. 8. Using natural drainage method, check the drainage is normal.
Pour the water in direction of arrow. Direction of the drained water 07 INSTALLATION • M ake sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part. Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following. 1.
Evacuating the connected pipes 1. Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut. Outdoor unit Indoor unit Gas pipe side 2. Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque. Liquid pipe side • Excessive torque can be cause of gas leakage. Outer Diameter • M ake the electrical connection and leave the system into “stand by mode”.
Important information regulation regarding the refrigerant used 1. Please fill in with indelible ink, Refrigerant type R-410A GWP value 2088 07 INSTALLATION This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. GWP=Global Warming Potential the factory refrigerant charge of the product, the additional refrigerant amount charged in the field and + the total refrigerant charge.
Performing the gas leak tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). A D C B Test part for outdoor unit Test part for indoor unit Tightening torque for body cap (Refer to the table) Before inspecting the leakage, use a torque wrench to close the cap for the service valve.
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. Insulation 07 INSTALLATION 1. To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. Pipes 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3.
Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions. Execute Smart Install mode after installation. 1. Check the installation status of the air conditioner. 1) Check the power supply, service valve (if it's open), power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension. 2) Status of the indicator after supplying the power : Standby status 2.
2) Smart Install mode in progress • 88 Display : Progress will be diplayed in 0~99. • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink. (This will be repeated.) 88 Display LED Display LED 1 LED 2 LED 3 Indoor unit indicator 07 INSTALLATION TYPE Display may be different depending on the model. 3. Smart Install mode will end. 1) Smart Install mode will take approximately 7~13 minutes. (Actual time may be different depending on the model.
Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1.
How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already.
QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT UK EIRE www.samsung.com/uk/support www.samsung.com/ie/support PORTUGAL LUXEMBURG NETHERLANDS 0330 SAMSUNG (7267864) 0818 717100 0180 6 SAMSUNG bzw. 0180 6 7267864* (*0,20 €/Anruf aus dem dt. Festnetz, aus dem Mobilfunk max. 0,60 €/Anruf) [HHP] 0180 6 M SAMSUNG bzw. 0180 6 67267864* (*0,20 €/Anruf aus dem dt. Festnetz, aus dem Mobilfunk max. 0,60 €/Anruf) 01 48 63 00 00 800-SAMSUNG (800.7267864) [HHP] 800.Msamsung (800.
ARJS Series Air Conditioner user & installation manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. AR5000 ET_IB&IM_DB68-05220A_HP_EN.