User Manual

Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before xing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
A
C
B
D
D
Direction of pipe
1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter
of 65mm so that it slants slightly downwards.
•Right(A)
•Left(B)
•Underside_right(C)
•Rear_rightorleft(D)
Wall
<20mm
Plastic
Anchor
2. Fix the indoor unit.
If youx the indoor unit on a wall
(1)Fixtheinstallationplatetothewallgivingattentiontotheweightoftheindoorunit.
If youx the indoor unit on a window frame
(1)Determinethepositionsofthewoodenuprightstobeattachedtothewindowframe.
(2)Attachthewoodenuprightstothewindowframegivingattentiontotheweightoftheindoorunit.
(3)Attachtheinstallationplatetothewoodenuprightusingtappingscrews.
If youx the indoor unit on a gypsum board
(1)Usestudndertondoutlocationsofthestuds.
(2)Fixtheplatehangerontwostuds.
• Ifyoumounttheplatetoaconcretewallusingplasticanchors,makesurethatgaps
between the wall and the plate, created by projected anchor, is less than 20mm.
• Searchforotherspotsiftherearelessthantwostuds,orthedistancebetweenthestudsaredierentfromthe
plate hanger.
• Fixtheinstallationplatewithoutincliningtooneside.
• Makesurethatawallcanwithstandtheweightoftheproduct.Ifyouinstalltheproductinaplacewhereitisnot
strong enough to withstand the product weight, the unit could fall and cause injury.
• Makesuretodrillonlyoneholeafterchoosing
the direction of the pipe.
(Unit:mm)
Model A B C D
AR09AWK
36 60 65 36
AR09BWK/CWK/BUR
12
AR07HSFN/HSFS
36 120 81 36
B
A
D
C
B
A
D
C
Pipehole(Ø65mm)
Pipehole(Ø65mm)
English-36