Eco Design Information

heating Y
Warmer
(if designated)
Y
Colder
(
if desi
g
nated
)
N
According to Commission Regulation (EU) No 206/2012
Function (indicate if persent)
If function includes heating: Indicate the heating season the
informaiont relates to. Indicated values should relate to one
heating season at a time. Include at least the heating season
'Average'
cooling Y
Average
Y
ErP Information(AC Product) AR09FSFPDGMN / AR09FSFPDGMX
Item symbol value unit Item symbol value unit
Cooling Pdesignc 2,5 kW cooling SEER 5,1 -
heating/Average Pdesignh 2,5 kW heating/Average SCOP/A 3,4 -
heating/Warmer Pdesignh 2,5 kW heating/Warmer SCOP/W 4,0 -
heating/Colder Pdesignh - kW heating/Colder SCOP/C - -
Item symbol value unit Item symbol value unit
Tj = 35 ℃ Pdc 2,5 kW Tj = 35 ℃ EERd 3,4 -
Design load Seasonal efficiency
Declared capacity(*) for cooling, at indoor temperature
27(19) ℃ and outdoor temperature Tj
Declared energy efficiency ratio(*), at indoor temperature
27(19) ℃ and outdoor temperature Tj
(if
designated)
Tj = 30 ℃ Pdc 1,9 kW Tj = 30 ℃ EERd 4,7 -
Tj = 25 ℃ Pdc 1,2 kW Tj = 25 ℃ EERd 6,0 -
Tj = 20 ℃ Pdc 1,2 kW Tj = 20 ℃ EERd 8,0 -
Tj = - 7 ℃ Pdh 2,3 kW Tj = -7 ℃ COPd 2,5 -
Tj = 2 ℃ Pdh 1,4 kW Tj = 2 ℃ COPd 3,4 -
Tj = 7 ℃ Pdh 0,9 kW Tj = 7 ℃ COPd 4,1 -
Tj = 12 ℃ Pdh 1,0 kW Tj = 12 ℃ COPd 4,9 -
Tj = bivalent
temperature
Pdh 2,5 kW
Tj = bivalent
temperature
COPd 2,4 -
Tj i li i
Pdh
25
kW
Tj i li i
COPd
24
Declared capacity(*) for heating/Average season, at indoor
temperature 20 ℃ and outdoor temperature Tj
Declared coefficient of performance(*)/Average season,
at indoor temperature 20 ℃ and outdoor temperature Tj
Tj = operating limit Pdh 2,5 kW Tj = operating limit COPd 2,4 -
Tj = 2 ℃ Pdh 2,5 kW Tj = 2 ℃ COPd 2,8 -
Tj = 7 ℃ Pdh 1,5 kW Tj = 7 ℃ COPd 4,5 -
Tj = 12 ℃ Pdh 1,0 kW Tj = 12 ℃ COPd 5,1 -
Tj = bivalent
temperature
Pdh 2,5 kW
Tj = bivalent
temperature
COPd 2,8 -
Tj = operating limit Pdh 2,5 kW Tj = operating limit COPd 2,4 -
Tj = 7 ℃
Pdh
kW
Tj = 7 ℃
COPd
Declared capacity(*) for heating/Warmer season, at indoor
temperature 20 ℃ and outdoor temperature Tj
Declared coefficient of performance(*)/Warmer season,
at indoor temperature 20 ℃ and outdoor temperature Tj
Declared capacity(*) for heating/Colder season, at indoor
temperature 20 ℃ and outdoor temperature Tj
Declared coefficient of performance(*)/Colder season,
at indoor temperature 20 ℃ and outdoor temperature Tj
Tj
= -
7
Pdh
-
kW
Tj
= -
7
COPd
--
Tj = 2 ℃ Pdh - kW Tj = 2 ℃ COPd - -
Tj = 7 ℃ Pdh - kW Tj = 7 ℃ COPd - -
Tj = 12 ℃ Pdh - kW Tj = 12 ℃ COPd - -
Tj = bivalent
temperature
Pdh - kW
Tj = bivalent
temperature
COPd - -
Tj = operating limit Pdh - kW Tj = operating limit COPd - -
Tj = -15 ℃ Pdh - kW Tj = -15 ℃ COPd - -
heating/Average Tbiv -10 heating/Average Tol -10
heatin
g/
Warme
r
Tbi
2 heatin
g/
Warme
r
Tol -10
Bivalent temperature Operating limit temperature
heating/Warmer
2
heating/Warmer
Tol
10
heating/Colder Tbiv - heating/Colder Tol -
for cooling Pcycc - kW for cooling EERcyc - -
for heating Pcych - kW for heating COPcyc - -
Degradation
co-efficient
cooling(**)
Cdc 0,25 kW
Degradation
co-efficient
heating(**)
Cdh 0,25 -
off mode
P
OFF
0,0 kW cooling
Q
CE
172 kWh/a
Cycling interval capacity Cycling interval efficiency
Electric power input in power modes other than
'active mode'
Annual electricity consumption
O
g
Q
C
standby mode
P
SB
0,0 kW heating/Average
Q
HE
1029 kWh/a
thermostat-off mode
P
TO
0,1 kW heating/Warmer
Q
HE
875 kWh/a
crankcase heater
mode
P
CK
0,0 kW heating/Colder
Q
HE
- kWh/a
fixed
Sound power level
(indoor/outdoor)
L
WA
54,0/59,0 dB(A)
staged
Global warming
potential
GWP 1975
kgCO
2
eq.
variable
Rated air flow
600/1920
m
3
/h
N
N
Y
Capacity control (indicate one of three options) Other items
v
ariable
(indoor/outdoor)
-
600/1920
m
3
/h
Contact details for
obtaining more
information
Y
http://www.samsung.com
(*) For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of
the unit' and 'declared EER/COP' of unit.
(**) If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling
cycling test value is required.

Summary of content (1 pages)