Features of your new air conditioner Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. Beat the heat with your own air conditioner this summer.
USING PARTS Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Important safety symbols and precautions: WARNING Hazards or unsafe practices that may result in severe personal injury or death. CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage. Follow directions.
Safety precautions FOR POWER SUPPLY WARNING Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth on a regular basis. Unplug the power plug and clean it with a dry cloth. Failing to do so may result in electric shock or fire. Plug the power plug into the wall socket in the right direction so that the cord runs towards the floor.
FOR USING WARNING ENGLISH Do not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children seriously injuring themselves. Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people. Since this may be dangerous due to a lack of oxygen, Open a window at least once an hour.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. Mode Indoor temperature Outdoor temperature Indoor humidity Cooling 16˚C~32˚C -10˚C~46˚C Relative humidity 80% or less Heating 27˚C or less -15˚C~24˚C - Dry 18˚C~32˚C -10˚C~46˚C - If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
Checking the name of the parts Your air conditioner may slightly look different from illustration shown above depending on your model. Main parts ENGLISH Humidity sensor Room temperature sensor Air intake Full HD filter(under the panel) Air flow blade (left and right) SPi indicator Air flow blade (up and down) Display indicator Remote controller receiver Timer indicator d'light Cool indicator 7 AQV09K&Y@@_Jungfrau_IBIM_E_32448A.
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display. Remote controller buttons Before using the functions of the remote controller, you should set the current time. (Refer to p.14) Remote controller display Power Turn on/off the air conditioner.
Remote controller display On Timer indicator Off Timer indicator indicator ENGLISH Operation mode indicator Low battery indicator Transmit indicator Quiet indicator Turbo indicator SPi indicator Smart Saver indicator d'light Cool indicator 2ndF indicator Set temperature indicator Air swing indicator Fan speed indicator Time indicator Auto (Turbo) Low Medium High • Make sure that the water does not get to the remote controller.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature. • If using a multi system, in Auto operation, the system selects a temperature setting and an appropriate operation mode (COOL or HEAT) based on the room temperature at the start of the operation.
Press the button to turn on the air conditioner. Press the button to set the operating mode. ENGLISH • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. Press the button to set the desired fan speed. Auto (Auto) Cool (Auto), Dry (Auto) Fan Heat Press the (Low), (Auto), (Low), (Med), (Low), (Med), (High) (High) (Med), (High) button to adjust the temperature.
Adjusting the air flow direction Air flow can be directed to your desired position. Vertical air flow Air flow blades move up and down. Press the Air swing button on the remote controller. Air swing indicator will be on the remote controller display and air flow blades move up and down continuously to circulate the air. Press the Air swing button on the remote controller again, to keep the air flow direction in a constant position. Horizontal air flow Air flow blades move left and right.
mode Before using good' sleep mode, set the current time.(For setting current time, refer to the page 14.) For a comfortable sleep, the air conditioner will operate it Fall asleep Sound sleep Wake up from mode. button on the remote controller. 1. Press the indicator appears and Off timer indicator starts blinking on the remote controller display. 2. Press the ENGLISH When the air conditioner is on and in cool/heat mode button to set the time.
Setting the Current time Before using the functions of the air-conditioner, set the current time. 1. Press 2ndF button 2ndF indicator appears on the remote controller display. 2. Press Time Set button to set the current time AM or PM indicator will blink and you can set the time by pressing Temp hr. + or – button for hour and Fan min. button for minute. 3. Press Time Set button again to active it.
Setting Off timer 3. Press the Set/Cancel button to active it. On timer indicator stops blinking and reserved time will be displayed for 3 seconds. If you don’t press Set/Cancel button within 10 seconds after selecting the time the air conditioner will return to previous status. Check On timer or Off timer indicator and indicator on the indoor unit. ENGLISH Cancel Press the Set/Cancel button once again.
Using the Smart Saver function This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode. Press the Smart Saver button on the remote controller while the air conditioner is operating in Cool mode. Smart Saver indicator and air swing indicator remote controller display. The air flow blades move up and down. appears automatically on the If the current set temperature is lower than 24°C, it will automatically raise to 24°C.
Using the Auto Clean function Auto clean function will prevent mold from growing by eliminating the moisture inside of the indoor unit. Your indoor unit evaporates the moisture inside of the unit. Activate this function to provide you with more clean and healthier air. ENGLISH Press the Auto Clean button. When the air conditioner is turned off, The Auto clean indicator on the indoor unit display appears and the Auto cleaning function runs.
Using the Quiet function AA You can reduce the noise generated from an indoor unit. Press the Quiet button on the remote controller while the air conditioner is operating in Cool/Heat mode. Quiet indicator appears on the remote controller display. The indoor unit will operate more quietly. Cancel Press the Quiet button once again. • If using a multi system, this function will work only when the Quiet function is set on all operated indoor units. 18 AQV09K&Y@@_Jungfrau_IBIM_E_32448A.
Cleaning the air conditioner • Make sure the power is turned off and unplugged from the wall socket when cleaning the air conditioner. ENGLISH Cleaning the indoor unit Wipe the surface of the unit with a slightly damp micro fiber cloth when needed. • C ontact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled. • Since the panel of the indoor unit is easily scratched, you should use a micro fiber cloth to clean the panel.
Cleaning the air conditioner Removing the Full HD filter Grab the handle and lift it up. Then, pull the Full HD filter towards you and slide it down. Full HD filter Cleaning the Full HD filter Washable foam based Full HD filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Open the panel and put the Full HD filter out. Clean the Full HD filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness. ENGLISH 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not work at all. • Check power status and then operate the air conditioner again. • Plug in or switch on the circuit breaker and then operate the air conditioner again. • Check if you have set the Off Timer. Operate the air conditioner again by pressing the Power button. The temperature adjustment is not working.
SOLUTION Error is indicated. , • If error indicator such as All blink, , , , , , , , contact nearest contact center. , , , , , , , , , , , , , , , appears on the indoor unit display, ENGLISH PROBLEM Noise is generated. • D epending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. It is normal. Smoke is generated from the outdoor unit.
INSTALLATION PARTS ※ In this manual, you may find model names written in simplified forms as indicated in following table. Model Names AQVK AQVY 09 12 18 Included Models AQV09K, AQV12K, AQV18K AQV09Y, AQV12Y, AQV18Y AQV09K, AQV09Y AQV12K, AQV12Y AQV18K, AQV18Y Remark Grouping was done by series. Grouping was done by capacity. Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.
Installing the unit IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.
Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3m or more away from the TV or radio (to prevent the scr
Space Requirements for Outdoor Unit If using a multi system, install as described in the installation manual supplied with the outdoor unit. ENGLISH When installing 1 outdoor unit ◆Figure Description Top view Side view Air intake Air outlet Air intake Air outlet , Air flow direction.
600 or more 500 or more 600 or more (Unit : mm) ◆ When the upper part of the outdoor unit and the air outlet is opposite the wall 1500 or more 300 or more ◆ When the walls are blocking front and the rear side of the outdoor units 300 or more 500 or more Choosing the installation location 300 or more ◆ When front and rear side of the outdoor unit is towards the wall 1500 or more 600 or more 3000 or more 3000 or more 200 or more • I f installation is done in inappropriate space, unit may gene
Optional accessories If using a multi system, refer to the manual supplied with the outdoor unit. The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner. Insulated Assembly Pipe, Ø9.52mm (1) 09/12 Pipe Clamps A (3) Pipe Clamps B (3) Insulated Assembly Pipe, PE T3 Foam Tube Ø12.
Fixing the installation plate 2. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards. (Unit : mm) Model AQVK/Y A B C 20 120 95 D 20 D A Pipe hole (Ø65mm) B • M ake sure to drill only one hole after choosing the direction of the pipe. C 3. Fix the indoor unit.
1. Extend the assembly cable if necessary. • Do not connect two or more different cables to extend the length. It may cause fire. 2 . Open the front grille. ENGLISH 3 . Remove the screw securing the connector cover. 4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below) • Each wire is labeled with the corresponding terminal number. 5 . Pass the other end of the cable through the 65mm hole in the wall. 6 .
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
Purging the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flow out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. ENGLISH 1. Unscrew the caps at the end of each pipe. All inert gas exhausts from the indoor unit.
Cutting or extending the pipe 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Correct Inclined Damaged Surface Cracked Uneven Thickness 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque. Outer Diameter ø6.35 mm ø9.52 mm ø12.70 mm ø15.88 mm ø19.05 mm ø22.
Drain hose installation 1. If necessary, connect the 2-meter extension drain hose to the drain hose. 2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield. • If you do not use the other drain hose hole, block it with a rubber stopper. 4. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. 5. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. ENGLISH 3.
Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following. 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. • T o avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit. Drain plug Drain hole Bottom surface of outdoor unit 2.
3. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture. 4. Open the valve of the low pressure side of manifold gauge counterclockwise. 5. Purge the air in the connected pipes using the vacuum pump for about 15 minutes. Valve Gas service port ENGLISH Make sure that pressure gauge shows -0.1MPa(-76cmHg) after about Manifold gauge 10 minutes. This procedure is very important to avoid a gas leak.
Purging the connected pipes Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. 1. Please fill in with indelible ink, Refrigerant type R410A GWP value 1975 GWP=Global Warming Potential Contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Performing the gas leak tests If using a multi system, refer to the manual supplied with the outdoor unit. Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). ENGLISH A C D B To check for gas leaks on the outdoor unit, Check the valve A and B using a leak detector.
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priorly. After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. Insulation 1. To avoid condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. Pipes 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3.
Final Check and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. 1.
How to connect your extended power cables I tems to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Spec Crimping plier Connection sleeve (mm) Insulation tape Contraction tube (mm) MH-14 20xØ7.0(HxOD) Width 18mm 50xØ8.0(LxOD) Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already.
Sub PCB installation(optional) Only for multi system (Wried remote controller, central remote controller etc.) 1. Turn the power off and take off the front panel of the indoor unit. ENGLISH 2. Take off the Cover PCB. Cover PCB 3. Attach the Sub PCB to the right side of the Panel frame. 4. Find the PCB wire, and connect the wire to the Sub PCB as seen in the picture. Sub PCB 5. Connect the wire(remote controller, central remote controller etc) to the Sub PCB. 6.
QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA 0810 - SAMSUNG (7267864, € 0.07/min) BELGIUM 02-201-24-18 www.samsung.com www.samsung.com/be (Dutch) www.samsung.com/be_fr (French) www.samsung.com www.samsung.com/bg www.samsung.com/hr www.samsung.com www.samsung.com www.samsung.com www.samsung.
AQV09K Series AQV12K Series AQV18K Series AQV09Y Series AQV12Y Series AQV18Y Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register E S F I P D G Bu Ro Cr Se Jungfrau_AQV09K&Y@@_IBIM_32448A_E.