Outdoor unit PH28ZA1 APH2840E PH28ZA1X UPH2840E ENGLISH ESPAÑOL DEUTSCH FRANÇAIS Split-type Packaged Air Conditioner (Cool and Heat) Grieta de Colmado de Aire Acondicionado (Refrigeración y Calefacción) Un tipo Sfalsalto Confezionato (Raffreddamento e Riscaldamento) Aparelho de Ar Condicionado do Tipo-Dividido (Refrigeração e Aquecimento) Climatiseur Monobloc de Type Split (Refroidissement et Chauffage) Split-typ Pauschal Klimaanlage (Kühlen und Wärmen) ITALIANO Indoor unit PORTUGUÉS OWNER’S INSTRU
Safety Precautions The following safety precautions must be taken when using your air conditioner. 1 Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 2 NEVER spill liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist. 3 Do NOT insert anything between the air flow blades, as the inner fan may become damaged and you may be hurt.
ENGLISH Contents ◆ PREPARING YOUR AIR CONDITIONER ■ Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . . . . . . . ■ Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ Inserting the Remote Control Batteries . . . . . . . . . . .
View of the Unit Indoor Unit Outer Air Flow Blades Inner Air Flow Blades Control Panel (refer to page 5) Air Filter (Inside) Air Inlet How to open the front panel ◆ Hold the upper part of the front panel, then pull it slightly forward.
ENGLISH Outdoor Unit Air Inlet(Rear) Connection Valve Air Outlet Control Panel Temperature setting Remote control sensor Power indicator Deice indicator HEAT FAN Operating mode indicators DRY Fan speed indicators COOL AUTO Operating indicators Operating indicator Fan speed selection button Timer indicator Swing indicator Temperature adjustment buttons Operating mode selection button (Auto, Cool, Dry, Fan, Heat) On/Off button Turbo button E-5
Remote Control - Buttons and Display Remote control transmission indicator Operating mode ( Dry, Auto, Fan, Cool, Heat) Temperature setting Turbo mode Sleep mode Long mode Fan speed Air flow directions On Timer setting Off Timer setting Mode selection button (Auto, Cool, Dry, Fan, Heat) Temperature adjustment buttons Turbo/Sleep/Long mode selection button Fan speed adjustment button Swing buttons On Timer button Off Timer button Battery discharge indicator On/Off & Timer Set/Cancel button E-6
ENGLISH Getting Started You have just purchased a split-type packaged air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features. The booklet is organized as follows.
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : ◆ You purchase the air conditioner ◆ The remote control does not work correctly Note ◆ ◆ ◆ ◆ Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
ENGLISH Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The POWER indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used.
Cooling Your Room You must select the Cool mode if you wish to adjust the: ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The POWER indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
ENGLISH Heating Your Room You must select the Heat mode if you wish to adjust the: ◆ Heating temperature ◆ Fan speed when heating 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The POWER indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the Result: ◆ The POWER indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
ENGLISH Changing the Room Temperature Quickly The Turbo cooling/heating function is used to cool/heat your room as quickly as possible. Example : You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected. 1 If necessary, press the Result: 2 Press the button one or more times until remote control.
Selecting the Long Function You can use the Long cooling/heating function when you wish to make the cool/warm air run to every corner in your room, especially when you are away from the air conditioner. 1 If necessary, press the Result: 2 3 Press the button one or more times until remote control. E-14 is displayed on the Result: ◆ The temperature and fan settings are adjusted automatically. ◆ The air conditioner cools/heats the room as far as possible.
ENGLISH Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the Result: 2 3 (On/Off) button. ◆ The POWER indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps. If the is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears.
Adjusting the Air Flow Direction Vertically You can adjust the position of the outer air flow blade on the upper part of the unit, thus increasing the efficiency of the air conditioner. 1 Press the button one or more times as required. Result: The outer blade is adjusted vertically. RECOMMENDATION E-16 When... Adjust the blade to face... Cooling Upwards. Heating Downwards. 2 If you want the blade to move up and down automatically when the air conditioner is operating, press the button.
ENGLISH Adjusting the Air Flow Direction Horizontally Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. 1 Press the Result: 2 ◆ The inner blade is adjusted horizontally. If you want blade to move left and right automatically when the air conditioner is operating, press the button. Result: 3 button one or more times as required. ◆ The blades move left and right, around the base position set.
Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the ON TIMER button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the Result: 3 (Set/Cancel) button to complete the setting. ◆ The remaining time is displayed. ◆ Blinking of the timer indicator stops.
ENGLISH Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the OFF TIMER button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the Result: (Set/Cancel) button to complete the setting. ◆ The remaining time is displayed. ◆ Blinking of the timer indicator stops.
Setting the Sleep Timer The Sleep Timer can be used when you are cooling/heating your room to switch the air conditioner off automatically after a period of six hours. Note If you wish to switch the unit off at a specific time, refer to page 19. 1 If the or is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears. 2 Press the button one or more times until remote control. appears on the ◆ The indoor unit beeps.
ENGLISH Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Heating performances The heat pump inside the air conditioner absorbs heat from outside air and brings it indoors. If the temperature of the outside air drops, the air conditioner will heat less. If you find that the room is not warm enough, use an additional heating appliance.
Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes.
ENGLISH Cleaning Your Air Conditioner To get the best possible use out of your air conditioner, you must clean it regularly by two weeks to remove the dust that accumulates on the air filter. IMPORTANT Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit. 1 Hold the upper part of the front panel, then pull it slightly forward. 2 Hold the edge of the air filter under the front panel and pull to release them.
Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem E-24 Explanation/Solution The air conditioner does not operate at all. ◆ Check that the breaker used for the air conditioner is switched on. ◆ Check that the POWER indicator on the indoor unit is on; if necessary press the (On/Off) button on the remote control. ◆ Check whether the TIMER indicator on the indoor unit is switched on.
ENGLISH Technical Specifications Model Power Supply PH28ZA1 APH2840E 220-240V~, 50Hz E-25
THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: DIESE KLIMAANLAGE IST FABRIZIERT VON: ELECTRONICS Printed in Korea