OWNER’S INSTRUCTIONS Indoor Unit Outdoor Unit AMF09C2E AMF12C2E AMF18C2E UMF26C2E3 UMF30C2E4 FREE JOINT MULTI ROOM AIR CONDITIONER (Cool) E DB98-09657A(1)
Safety Precautions The following safety precautions must be taken when using your air conditioner. 1 Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 2 NEVER spill liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist. 3 Do NOT insert anything between the air flow blades, as the inner fan may become damaged and you may be hurt.
Contents ◆ PREPARING YOUR AIR CONDITIONER ■ Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 ■ View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 ■ Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . .6 ■ Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 ■ Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . .
View of the Unit Indoor Unit Power Standard Nature Saving Silence Timer Air Inlet Air filter (under the grille) On/Off & 5 Way selection button/ Remote Control Sensor/ Inverter Power Monitor indicator Air flow blades (outlet) Power Standard Nature Saving Silence Timer Standard indicator Timer indicator Silence indicator Nature indicator Saving indicator Power indicator Note ◆ For details on the 5 Way, refer to page 9.
Outdoor Unit Air Inlet(Rear) SH30ZC1(C2)X Air Outlet Connection Valve E-5
Remote Control - Buttons and Display Remote control transmission indicator Operating mode ( AUTO, DRY, COOL, FAN) Temperature setting Turbo mode Sleep mode Fan speed Mode selection button (AUTO, COOL, DRY, FAN) Temperature adjustment buttons Turbo/Sleep mode selection button Air flow direction Fan speed adjustment button Swing button On Timer setting On Timer button Off Timer setting Off Timer button Battery discharge indicator 5 Way selection button E-6 On/Off & Timer Set/Cancel button
Getting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features. The booklet is organized as follows.
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : ◆ You purchase the air conditioner ◆ The remote control does not work correctly Note ◆ ◆ ◆ ◆ Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
5 Way Function You can select the 5 Way function with operating mode of the air conditioner for more comfortable circumstances. You can use the 5 Way function with the indoor unit as well as the remote control. Thus, you can use this function even though you have lost your remote control. Using with the indoor unit 1 Press the mode. (ON/OFF) button one time and then select the desired To obtain a(n)... Then select...
Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The 5 Way indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
Cooling Your Room You must select the Cool mode if you wish to adjust the: ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The 5 Way indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
Changing the Room Temperature Quickly The Turbo cooling function is used to cool your room as quickly as possible. Example : You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected. 1 If necessary, press the Result: 2 Press the Result: 3 E-12 ◆ The 5 Way indicator on the indoor unit lights up.
Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the Result: ◆ The 5 Way indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps. IMPORTANT 2 (On/Off) button.
Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the Result: 2 ◆ The 5 Way indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps. If the is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears. Result: Note 3 (On/Off) button.
Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the SWING button one or more times as required. Result: The outer blade is adjusted vertically. RECOMMENDATION 2 When... Adjust the blade to face... Cooling Upwards.
Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the ON TIMER button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the Result: 3 (Set/Cancel) button to complete the setting. ◆ The remaining time is displayed. ◆ Blinking of the timer indicator stops.
Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the OFF TIMER button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the Result: (Set/Cancel) button to complete the setting. ◆ The remaining time is displayed. ◆ Blinking of the timer indicator stops.
Setting the Sleep Timer When you are cooling your room, the Sleep Timer can be used to switch the air conditioner off automatically after a period of six hours. Note If you wish to switch the unit off at a specific time, refer to page 17. 1 If the is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears. 2 Press the button one or more times until remote control. ◆ The indoor unit beeps.
Operating Recommendations Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically.
Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes.
Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not operate at all ◆ Check that the breaker used for the air conditioner is switched on. ◆ Check that the 5 Way indicator on the indoor unit is on; if necessary press the (On/Off) button on the remote control. ◆ Check whether the TIMER indicator on the indoor unit is switched on.
Installing a Filter (Option) The air conditioner can be fitted with a deodorizing and Bio-Pure filter to remove minute dust particles or odours. The service life of the filter is approximately three months depending on the time during which the air conditioner is used. 1 Note Deodorizing filter Bio-Pure Filter E-22 Remove the vinyl packing from the filter. Do not remove the packing from a deodorizing filter until you wish to use the filter, as it will lose its properties.
Technical Specifications Model Power Supply AMF09C2E AMF12C2E 220-240V~, 50Hz AMF18C2E E-23
THIS AIR CONDITIONER IS MANUFACTURED BY: ELECTRONICS Printed in Korea