Code
U1-2320
Error message
Fuser Unit Failure: #U1-2320. Turn off then on
Symptom / Cause
The fuser unit is not installed or AC is not supplied to the Heat Lamp.
Thermistor is defective.
Troubleshooting method
1. Check if the fuser unit is installed properly. Turn the machine off then on.
2. Remove the fuser unit. Remove the COVER-UPPER. And measure the thermostat continuity.
Check if the thermostat is opened.
3. Measure the LAMP-HALOGEN resistance value from the center and both sides.
Check if it has the continuity.