Service manual

4. Alignment and Troubleshooting
Service Manual
ML-551x / 651x series
4-78
Samsung Electronics
 Code
H2-1760
H2-1A80
 Error message
Finisher Failure: #H2-1760. Check fi nisher
Finisher Failure: #H2-1A80. Check fi nisher
 Symptom / Cause
Stacker Unit is not working.
Stacker Level sensor, Stack Full sensor, Stacker Motor Harness Connection not well or damaged, Main Board
damaged.
 Troubleshooting method
1. Check the Main Board Harness Connection.
2. Check the Stacker Level Sensor’s Harness
Connection and Actuator’s operation & its Spring
behind the wall.
3. Check the Stacker Motor Harness Connection
and operation.
4. Check the Stack Full Sensor Connection and
operation.
5. If the same problem happens after checking 1~3,
Replace the Finisher main board.
6. If the same problem happens after checking 4,
replace the Finisher harnesses.