Service manual
4. Alignment and Troubleshooting
Service Manual
ML-551x / 651x series
4-48
Samsung Electronics
Code
A2-1910
Error message
Actuator Fan Failure: #A2-1910. Turn off then on.
Symptom / Cause
The Main(SMPS) Fan does not work normally.
1. Fan Harness connection is bad.
2. Harness is defective or GND is short.
3. Fan is defective.
Troubleshooting method
1. Check if the Fan Relay connector is connected properly.
2. Connect the Harness Housing correctly.
3. Check if the Fan harness is normal. If it is defective, replace it.
4. Enter the Tech mode and execute the Main Fan test (EDC code : 100-0260 (SMPS FAN).
To enter the Tech mode, press the button in this order.
(Menu - # - 1 - 9 -3 -4 - OK )
SMPS FANSMPS FAN