Installation manual
22
AA
Setting an indoor unit address and installation option
You can change each digit of set option.
Changing a particular option
Option
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation
PAGE MODE
The option mode
you want to
change
The tens’ digit of an
option SEG you will
change
The unit digit of
an option SEG you
will change
The changed value
Remote
Controller
Display
Indication
and
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
0 D
Option
mode
0~F
Tens’ digit
of SEG
0~9
Unit digit
of SEG
0~9
The
changed
value
0~F
• When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’.
• When changing a digit of indoor unit installation option, set the SEG3 as ‘2’.
Ex) When setting the 'buzzer control' into disuse status.
Option
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE
The option
mode you want
to change
The tens’ digit of
an option SEG
you will change
The unit digit of
an option SEG
you will change
The changed
value
Indication 0 D 2 1 7 1