Specifications
SAMSUNG Proprietary-Contents may change without notice
6-11
Circuit Description
Command No. Signal. Name Description
(OP, AB, RB)
77(D7, 0, 3) T_READ_TEMP_I Read Temp.
78(D8, 0, 3) T_READ_HDET_I Read High Detect.
79(D9, 1, 0) T_BUZZER_ON_I
2)
Buzzer On at DTMF 0 key.
80(DA, 0, 0) T_BUZZER_OFF_I Buzzer Off.
81(E3, 0, 0) T_VOC_PCMLPON_I Play a PCM LOOP BACK.
82(E4, 0, 0) T_VOC_PCMLPOFF_I Play off a PCM LOOP BACK.
85(E7, 0, 0) T_SPEAKER_ON_I Turn on the speaker path.
86(E8, 0, 0) T_SPEAKER_OFF_I Turn off the speaker path.
87(E9, 0, 0) T_AMPS_LOOP_TEST_I Play a PCM AMPS loopback.
88(EA, 0, 0) T_TRK_ADJ_I
3)
RM TRK_LO_ADJ control.
89(EB, 0, 0) T_CD_TRK_ADJ_I CDMA TRK _LO_ADJ control.
90(F0, 4, 0) T_HW_CHANFLAT_I HW flatness channel.
91(F1, 4, 0) T_SW_CHANFLAT_I SW flatness channel.
92(F2, 3, 0) T_AMPS_TX_PWR_2_I
2)3
) Setting the volume for Power Level.
93(F3, 3, 0) T_AMPS_TX_PWR_3_I
2)3)
Adjust the channel flatness of AMPS.
95(F4, 4, 0) T_PCS_HW_CHANFLAT_I PCS HW flatness channel
96(F5, 4, 0) T_PCS_SW_CHANFLAT_I PCS SW flatness channel.
97(F6, 4, 0) T_PCS_CH_CHANFLAT_I PCS channel flatness adjust.
98(F6, 0, 0) T_DATASVC_ON_I “DATA SVC ON”
99(F7, 0, 0) T_DATASVC_OFF_I “DATA SVC OFF”
100(FF, 4, 0) T_MAX_I
1) The AB (Input Argument Byte Number) values of these commands are used only in the manual test. In
automatic test mode, the AB is regarded as 0.
2) You can assign the value for these commands. If the AB value is assigned without argument, the test is
achieved with the value stored in EEPROM.
3) After you get a desired test value by performing these commands, if you want to save the value into
EEPROM, use T-SAVE-VAL-I command to store the test value into the corresponding position.
*OP: Operation Command Number
AB: Input Argument Byte Number
RB: Return Byte Number
*SAT 32, 33 are not operating in MSM2 CHIP test
*46 command is required in Rx, and Tx path test at AMPS mode.