Certifications 2
SAMSUNG SDI Confidential Proprietary
Spec. No.
INR18650-
35E
Version No.
Ver. 0
.0
zGzkpUSGiGiGkUG
5
7.5 Temperature Dependence of Discharge Capacity
Discharge capacity comparison at each temperature, measured with discharge
constant current 3,400mA and 2.65V cut-off with follow temperature after the Standard
charging at 23°C.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage as an index of the Standard discharge capacity (=3,350mAh) is 100%.
7.6 Temperature Dependence of Charge Capacity
Capacity comparison at each temperature, measured with discharge constant current
680mA and 2.65V cut-off at 23°C after the Standard charge is as follow temperature.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage as an index of the Standard discharge capacity (=3,350mAh) is 100%.
7.7 Charge Rate Capabilities
Discharge capacity is measured with constant current 680mA and 2.65V cut-off
after the cell is charged with 4.2V at 23°C as follows.
Note: Percentage as an index of the Standard discharge capacity (=3,350mAh) is 100%.
Charge Temperature
Discharge temperature
23°C
-10°C
23°C
40°C
Relative Capacity
40%
97%
97%
Charge temperature
Discharge temperature
0°C
23°C
45°C
23°C
Relative Capacity
60%
100%
100%
Charge Condition
Current
0.5C
(1,700mA)
1.0C
(3,400mA)
Cut-
off
3h or 0.02C 2.5h or 0.02C
Relative
Capacity
100% 97%