Specifications
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 17
43 05 Fusing temperature setting
in duplex copy (FU TEMP
DPLX) (Enabled when
Duplex setting is ON)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [OK (ENTER)/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
14 Fusing start temperature
setting (FU TEMP START)
[Function]
When this test command is started, the currently set code number is displayed.
Press [
←
/
→
/10KEY] to switch the setting, and press [OK (ENTER)/START] key to save it to the
EEPROM. The machine goes to the sub code entry standby mode.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents Details of function/operation
Code Shift temperature (°C) Remark
0 ±0 Default
1-8
2-6
3-4
4-2
5±0
6+2
7+4
8+6
9+8
Code Set temperature (°C) Remark
0 160
1 165
2 170
3 175
4 180
5 185
6 190
7 195 Default
8 200