Specifications

e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 34
66 11 300bps signal send (Max.
value) (Executable only
when the FAX is installed.)
[Function]
Use to set the 300bps signal send (Max. value).
1: NO SIGNAL
2: 11111
3: 11110
4: 00000
5: 010101
6: 00001
[Operation]
12 300bps signal send (Soft
SW set value) (Executable
only when the FAX is
installed.)
[Function]
Use to set the 300bps signal send (Soft SW set value).
1: NO SIGNAL
2: 11111
3: 11110
4: 00000
5: 010101
6: 00001
[Operation]
Main
code
Sub
code
Contents Details of function/operation
1) Initial display
2) [
/
] or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of No. 1
2
3
4
5
6
1.
When [
] key is pressed, the sequence is reversed.
[CLEAR] key: FAX control is terminated.
3) [OK (ENTER)] key
[CLEAR] key: Returns to "1) Initial display".
SELECT SIGNAL
PRESS ,
SELECT SIGNAL (1-6)
1:NO SIGNAL
..... SELECT SIGNAL (1-6)
6:00001
OUTPUTING SIGNAL MAX
PRESS CLEAR TO STOP
1) Initial display
2) [
/
] or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of No. 1
2
3
4
5
6
1.
When [
] key is pressed, the sequence is reversed.
[CLEAR] key: FAX control is terminated.
3) [OK (ENTER)] key
[CLEAR] key: Returns to "1) Initial display".
SELECT SIGNAL
PRESS ,
SELECT SIGNAL (1-6)
1:NO SIGNAL
..... SELECT SIGNAL (1-6)
6:00001
OUTPUTING SIGNAL SSW
PRESS CLEAR TO STOP
e-STUDIO162_151.book 34 ページ 2004年12月2日 木曜日 午後9時37分