Datasheet

http://www.samsungled.com
27 / 52
6.
Reliability Test Items and Conditions
1)
Test Items and Results
2)
Criteria for Judging the Damage
Item Symbol Test Condition
Limit
Min Max
Forward Voltage
V
F
I
F
= 100
Init. Value*0.9 Init. Value*1.1
Luminous Flux
Im I
F
= 100
Init. Value*0.8 Init. Value*1.2
Test Item Test Conditions
Test
Hours/Cycles
Sample No
MSL Test
125
24
hrs drying
60
, 60 %
RH
120
hrs
260
10
sec
3
cycles
1
cycle
11
Room Temperature
life test
25
±3
,
DC
200
1,000
hrs
22
High Temperature
life test
85
±3
,
DC
200
1,000
hrs
22
High Temperature
humidity life test
85℃
±3
, 85 %±2 %
RH, DC
200
1,000
hrs
22
Low Temperature
life test
-40
±3
,
DC
200
1,000
hrs
22
Power Temperature
Cycle
-40
/20
min
85
/20
min,
Temp. change within
100
min, on/off
5
min
100
cycles
50
Thermal Shock
-45
/15
min
125
/15
min,
Temp. change within
5
min
Hot plate
180
200
cycles
100
High Temperature
Storage
Ta=1
20
±3
1000
hrs
11
Low Temperature
Storage
Ta=-40
±3
1000
hrs
11
ESD(HBM)
R1:10
,
R2:1.5
,
C:100
, V = ±5
kV
5
times
10
ESD(
M
M)
R1:10
,
R2:
0,
C:
200
, V = ±0.5
kV
5
times
10
Vibration Test
100~2000~100
Hz,
200
m/s2,
Sweep
4
min,
X, Y,
Z 3
direction, each
1
cycle
4
cycles
11
Mechanical Shock Test
1500
G,
0.5
ms,
3
shocks each X-Y-Z axis
5
cycles
11