Datasheet

http://www.samsungled.com
13 / 28
5.
Reliability Test Items and Conditions
1)
Test Items and Results
Test Item
s
Test Conditions
Test
Hours/Cycles
n
Room Temperature
Life Test
25
,
DC
1000
1000
Hr
22
High Temperature
humidity Life Test
85
, 85%,
DC
1000
1000
Hr
22
High Temperature
Life Test
85
,
DC
1000
1000
Hr
22
Low Temperature
Life Test
-40
,
DC
1000
1000
Hr
22
Temperature humidity
Cycle On/Off test
-40 / 85
,
each
20
min
,100
min transfer
Power On/off each
5
min, DC
1000
100 C
ycles
11
Thermal Shock
-45
/15
min
125
/15
min
.
Temp.change within
5
min.
500 C
ycles
100
High Temperature
Storage
Ta=1
20
1000
Hr
11
Low Temperature
Storage
Ta=-40
1000
Hr
11
ESD(HBM) Q1=10
M
,
R2=1.5
K
,
C=100pF
,
V=
±5
KV
,5
Times
5T
imes
(±5kV)
5
2)
Criteria for Judging the Damage
*U
.
S
.
L
.
:
Upper Standard Level
L
.
S
.
L
.
:
Lower Standard Level
Item Symbol
Test Condition
[T
a
=25
]
Limit
Min
.
Max
.
Forward Voltage
V
F
350
mA L.S.L.
*0.9
U.S.L.
*1.1
Luminous flux lm
350
mA L.S.L.
*0.7
U.S.L.
*1.1