SSA-S3011 SSA-S3021 SSA-S3041 Standalone Biometric Access Controller user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time. FCC Statement Caution : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules.
contents PRODUCT INTRODUCTION 7 INSTALLATION AND EXTERNAL CONNECTION 14 INITIALIZATION 20 READER MODE SETUP 27 4_ Contents 7 9 10 12 13 Features What’s included At a glance Cable Color Scheme Cable Selection 14 15 16 18 Installing the rear template Bypass Diode Connection I/O Connection External Reader Connection 20 21 21 23 24 24 25 25 26 26 Initializing the system To access the master mode Registering a master ID Name Display User Count Setup Language Setup Date/Time Setup Communication Addres
USER MANAGEMENT 37 37 38 38 39 39 40 40 I/O TIME SETUP 41 41 41 42 42 43 43 44 44 45 45 49 Exit Button Output Door Contact Sensor Setup Auxiliary Input #1 Setup Auxiliary Input #2 Setup Tamper Alarm Output Setup Cut Off Output Setup Duress Mode Output Setup ARM/DISARM Output Setup Door Open Timeout Setup Output Setup for Level IDs Accessing READER #1 READER #1 Error Output Setup Output Setup for Level IDs Accessing READER #2 READER #2 Error Output Setup 51 51 52 52 53 54 55 56 56 57 57 Time Unit Set
contents ADDITIONAL FEATURES 58 OTHER INFORMATION 66 TROUBLESHOOTING 58 58 59 59 60 60 61 61 62 62 63 63 64 64 65 Event Memory Setup ID Display WIEGAND Output Setup Voice Volume Setup One Time Read Version Check Input Test Output Test LCD Test Keypad Test READER Test Memory Test Communication Test Fingerprint Module Version Check Input Type Setup 66 72 Menu Structure Default Settings 74 TroubleShooting 76 product specifications 74 PRODUCT SPECIFICATIONS 76 6_ Contents
product introduction FEATURES State-of-the-art Access Controller Standalone Operation SSA-S30XX is connected to the external card reader, which is used to control one entrance. It determines to allow access by reading data from the internal or external card reader, and controls the open/close of the door relay and other output settings. On an external signal (from a sensor or Exit button) reception, the device (relay) corresponding to the signal starts operating.
product introduction External I/O Pins SSA-S30XX has 4 input pins and 4 output pins installed(2 relay and 2 TTL outputs) The input pins can receive signals from the Exit button and the Door Contact sensor, while the two relays can be connected to the Door Lock and the alarm device. You can specify the output time for these output pins.
WHAT’S INCLUDED Check if the following items are included in the product package. PRODUCT INTRODUCTION Main Unit Wall Mount Cable (X 6) Diode (X 2) (UF4004, 1N4001~4007) Resistor (X 4) (2.2kΩ, 1/4W) 3.5 X 40mm screws (X 4) 3.
product introduction AT A GLANCE Front Panel LCD This module displays the operation status of the product. Fingerprint Scanner Fingerprint scanner module. The red indicator turns on when the product turns on. System Status LED The red indicator turns on when relay #1 becomes active. The yellow indicator turns on when relay #2 becomes active. 12 menu buttons ( F1 ~ F12 ) are available for use. Menu Buttons Press a menu button to enter the corresponding menu.
Rear Panel 4 5 6 11 10 9 8 3 2 1 RJ45 Connector Used in TCP/IP communications. 2 Tamper Switch Tamper switch. 3 Fixing Hole Hole for a fixing screw. 4 2-pin Connector Can be connected to the power cable. 5 3-pin Connector Preliminary connector for extension. 6 6-pin Connector Can be connected to the I/O cable. 7 8-pin Connector Can be connected to the relay wiring cable. 8 Initialize switch System Initialize switch. 9 LED Communication status indicator.
product introduction CABLE COLOR SCHEME ❖ 2-PIN Connector I/O Pins Signal Cable Color Power (+12V) DC +12V Red Earth-grounding GND (-) Black ❖ 3PIN Connector I/O Pins Signal Cable Color RESERVED 1 Pink with White Stripes RESERVED 2 Sky Blue with White Stripes RESERVED 3 Black ❖ 6-PIN Connector I/O Pins TTL Output #1 Signal Cable Color TTL#1, WIK_D_OUT0 Orange with White Stripes TTL Output #2 TTL#2, WIK_D_OUT1 Brown with White Stripes Auxiliary Input #1 AUX_IN#1 Green Auxiliary I
CABLE SELECTION Cable Type 1 Product Power (DC12V) This product Reader (power and data) External reader This product Belden #9512, 22 AWG, 4 Conductor, Shielded 2 Belden #9512, 22 AWG, 4 Conductor, Shielded 3 Door Contact Sensor Exit Button Sensor Input Input This product Belden #9409, 18 AWG, 2 Conductor, Unshielded (Maximum Allowable Distance : Within 3m) Belden #9514, 22 AWG, 8 Conductor, Shielded Belden #9514, 22 AWG, 8 Conductor, Shielded English13 PRODUCT INTRODUCTION Description
installation and external connection INSTALLING THE WALL MOUNT Follow the instructions below to install the wall mount. 1. Place the wall mount on the installation point and mark the 4 holes for the screws. Drill at least 4 of 6-32 holes. 2. Drill a 1/2” hole on the center of the wall mount. 3. Use 4 screws to fix the template to an appropriate point. 4. Arrange the cables through the center hole. 5. Connect the cable and use one screw on the bottom of the wall mount to fix it to the product.
BYPASS DIODE CONNECTION If you connected an inductor (door locks or alarm device) to the output relay, there should occur a surge voltage while the inductor was turning on and off. If you do not connect a bypass diode to the relay, the surge voltage will cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect a bypass diode between the devices. DC12V "-.
installation and external connection I/O CONNECTION Input Connection 183 "-. %003 Mon 12 / 12 / 2009 10 : 30 : 20 1 2 3 F1 F2 4 5 6 F4 F5 7 8 9 F7 F8 F9 ESC 0 ENT F10 F11 F12 F3 Door Contact Sensor: Yellow with the red stripe, GND Exit Button: Orange line, GND Connect 2.2K to check for cut-off detection F6 Door Contact Sensor Black - GND FG 100V-220V L Red + DC+12v N Exit Button Power Supply 1. Connect the DC 12V(+) line of the power supply unit to the red line. 2.
Output Connection Connect the 8-pin connector (relay connector) of this product as follows: 183 "-.
installation and external connection EXTERNAL READER CONNECTION External Reader Connection 183 "-. %003 Mon 12 / 12 / 2009 10 : 30 : 20 Wiegand DATA0 (Pink) Wiegand DATA1 (sky blue) 1 2 3 F1 F2 F3 4 5 6 F4 F5 F6 7 8 9 F7 F8 F9 ESC 0 ENT F10 F11 F12 ⾄⾇⾅ GND Black - Red + DC+12V ⾄⾉⾅ Power Supply - Proximity Reader Connection 1. Connect the DC 12V(+) line of the power supply unit to the plus (+) line of the reader. 2.
TCP/IP Communication Port Connection To implement TCP/IP communications for the host PC, follow the steps below: INSTALLATION AND EXTERNAL CONNECTION HUB TCP/IP TCP/IP PC 183 183 "-. 3 1 2 4 5 7 8 9 F7 F8 F9 0 ENT F10 F11 F12 F1 F4 "-. %003 %003 Mon 12 / 12 / 2009 10 : 30 : 20 ESC 6 183 "-.
Initialization INITIALIZING THE SYSTEM Initializing the system using the Initialize switch Initialize the system using the Initialize switch on the rear of the product. 1. Check the power terminal on the rear of the product and disconnect the power cable. INITIALIZE OK? 2. While holding the Initialize switch, connect the power cable again. 1:YES 0:NO 3. While holding the Initialize switch, wait until the “Initialize OK?” message appears on the screen. It takes about 8 seconds to proceed.
TO ACCESS THE MASTER MODE 1. Apply the power to the product. 0 8 consecutive times (00000000) and • The master number of the initialization is “00000000” (“0000000000” for SSA-S30X1). If you have already registered the master ID, use the ID to get access. M WELCOME!! ******** Mon 12 /12 2009 10 :30 : 20 When the system is initialized, the master number will be reset to “00000000” If you have registered the master ID, you can not get access using “00000000”.
initialization To register a master card along with your fingerprint Follow the steps 1 through 6 above in “To register a master card”. 7. Press 1 to register your fingerprint. 1/2 TO REGISTER F/P PUT YOUR FINGER 8. Place your finger on the fingerprint scanner. 9. Release your finger, then put your finger onto the fingerprint scanner again when the light turns on. 10. When done, the master ID and your fingerprint template will be registered.
To register a master card PIN along with your fingerprint Follow the steps 1 through 5 above in “To register a master card PIN” 6. Press 1 to register your fingerprint. 8. Release your finger, then put your finger onto the fingerprint scanner again when the light turns on. 9. When done, the master card PIN and your fingerprint template will be registered. LIFT AND PUT YOUR FINGER NAME DISPLAY With “Name Display”, you can set to display the name of a user who enters.
initialization USER COUNT SETUP You can select the maximum number of registered users to 10,000 or 20,000. If you set the maximum user count to 20,000, the maximum number of events will be changed to 10,000. 1. Press the F3 SETUP MENU button. 2. Use the buttons press ENT . 4 3. Use the buttons 4 and 6 and 6 to move to the MAX USER SETUP item and to select a max user count. 5. MAX USER SETUP 10000 • 10,000 : The max user count will be set to 10,000.
DATE/TIME SETUP 1. Press the F1 SETUP MENU button. 4 and 6 to move to the SET DATE/TIME item and 2. SET DATE/TIME YYYYMMDDhhmmssw 3. Enter the values of year, month, day, hour, minute, second, and day of the week in sequence. • YYYY : Year (4 digits) MM : Month (2 digits) DD : Day (2 digits) hh : Hour (2 digits) mm : Minute (2 digits) ss : Second (2 digits) w : Day of the week (1 digit) 1- Sunday, 2-Monday, 3-Tuesday, 4-Wednesday, 5-Thursday, 6-Friday, 7-Saturday 4.
initialization BAUD RATE SETUP This product supports 9600, 19200, 38400, and 57600 bps, and it is set to 57600 bps by default. An improper speed setting can cause a communication error so ensure that you specify the same speed in the same network. 1. Press the F1 SETUP MENU button. 2. Use the buttons ENT . 4 and 6 to move to the BAUD RATE item and press 3. Use the buttons 4 and 6 to select a serial communication speed. 8. BAUD RATE 57600 • 9600 19200 38400 57600 8.
reader mode setup READER #1 MODE READER#1 is the default reader that is built in this product. 1. Press the F1 SETUP MENU button. 4 and 6 to move to the READER#1 MODE item and 3. Use the buttons 4 and 6 to select a reader mode. 3 modes are available for your choice. • ID ONLY : In this mode, you can get access only with the proximity card or ID number. ID +F/P(P/W) : In this mode, you can get access through the fingerprint authentication after entering the proximity card or ID number.
reader mode setup READER #1 KEY INPUT This enables you to use the keypad (numeric keypad) of READER #1 to enter the ID. If you want to use the registered ID (card number or PIN) to get access, set this mode to USE. 1. Press the F1 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the RD#1 KEY INPUT item and 3. Use the buttons 4 and 6 to select the use of the keypad of READER#1. 5. RD#1 KEY INPUT NOT USE • USE : If set, you can get access using the keypad input.
DUAL FINGERPRINT MODE In Dual Fingerprint mode, you can register two fingerprints for one user ID. If one of your fingers is damaged with Dual Fingerprint mode set to USE, you can use the other finger registered for the authentication. F10 SETUP MENU button. 1. DUAL F/P MODE 2. Use the buttons press ENT . 4 3. Use the buttons 4 and 6 to move to the DUAL F/P MODE item and NOT USE and 6 to select the use of Dual Fingerprint mode. • USE : If set, you can use the Dual Fingerprint mode.
reader mode setup ADAPTIVE MODE In Adaptive mode, the fingerprint image will be automatically compensated in an attempt to increase the successful recognition rate of fingerprint authentication. 1. Press the F10 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the ADAPTIVE MODE item and 3. Use the buttons 4 and 6 to select the use of Adaptive mode. NOT USE • USE : If set, you can use the Adaptive mode NOT USE : If set, Adaptive mode is disabled 4.
user management REGISTERING ID IN QUICK MODE To register ID 1. Press the F12 SETUP MENU button. 4 and 6 to move to the REGISTRATION item and (QUICK MODE) 1. REGISTRATION 3. Use one of the following two ways to enter an ID: • Place the card on the main unit to display the card ID on the screen. • Use the keypad to enter the number and press ENT . 4. Enter the password and select whether to use the fingerprint and press ENT . • Set FINGER to 0. 5. ID registration is completed.
user management REGISTERING THE ID 1. REGISTRATION To register the ID card 1. Press the F7 SETUP MENU button. 1. REGISTRATION 2. Use the buttons press ENT . 4 and 3. Press the button 1 to select CARD. 6 to move to the REGISTRATION item and 1:CARD 2:PIN 1. REGISTRATION SCANNIG… • For card registration, select the card to register the ID. For PIN registration, select PIN and use the keypad to register the ID. 4. Put the card onto the main unit to display the card ID on the screen. 1.
To register the ID card along with your fingerprint Follow the steps 1 through 4 in “To register the card ID” above 5. Set each of PW/TA/TB/C/RD/MA/MB/LV/FP. 1/2 TO REGISTER F/P PUT YOUR FINGER • Set FP to 1. • Press ENT . 6. Place your finger on the fingerprint scanner. 7. Release your finger, then put your finger onto the fingerprint scanner again when the light turns on. 8. Your ID and fingerprint will be registered.
user management To register the PIN number along with your fingerprint Follow steps 1 through 4 in “To register the PIN number” above. 5. Set each of PW/TA/TB/C/RD/MA/MB/LV/FP. • For more information about each item, refer to “ID Registration Items” on page 35. 1/2 TO REGISTER F/P PUT YOUR FINGER • Set FP to 1. • Press ENT . 2/2 LIFT AND PUT YOUR FINGER 6. Place your finger on the fingerprint scanner. 7.
VIEWING THE ID LIST You can check the list of IDs registered with the product. 1. Press the F7 SETUP MENU button. 4 and 6 to move to the ID LIST item and press ENT . 3.ID LIST 3. The list of registered IDs appears on the screen. • The list of registered IDs appears on the screen.
user management TO REMOVE ALL REGISTERED IDs You can remove all of the registered user IDs. 1. Press the F8 SETUP MENU button. 2. Use the buttons press ENT . 4 3. Press the button 1 and 6 to move to the ALL ID CLEAR item and 3. ALL ID CLEAR to delete all registered IDs. • To cancel the work, press the button 0 . 3. ALL ID CLEAR 1:YES, 0:NO J Please upload the ID data to the host PC before deletion, just for backup purposes.
TO REMOVE THE MASTER IDs If you want to remove all master IDs (card IDs), use this menu. 1. Press the F8 SETUP MENU button. 4 3. Press the button 1 and 6 to move to the MASTER ID CLR item and 4. MASTER ID CLR to delete all registered master IDs. • To cancel the work, press the button 0 . 4.MASTER ID CLR 1:YES, 0:NO J Before removing all master IDs, ensure that the master IDs are no longer in use. DURESS MODE You can set Duress Mode for READER#1.
user management DOOR OPEN ALARM TIME SETUP In this menu, you can set the delay time until the product triggers the door open alarm if the door stays open after the Door Relay time. To use this function, the Door Contact sensor should have been installed on the entrance door. (see page 17) The default is ‘03’. 1. Press the F2 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the OPEN ALR TIME item and 3. Use the keypad to enter the time in two digits and press ENT 03 .
TWO MEN OPERATION MODE With TWO MEN MODE active, the door will be opened if both administrator card and visitor card are entered in a row within 10 seconds. 1. Press the F3 SETUP MENU button. 4 3. Use the buttons 4 and 6 and 6 to move to the TWO MEN MODE item and to select USE or NOT USE, and press ENT • USE : TWO MEN MODE is enabled. NOT USE : TWO MEN MODE is disabled. . 3.TWO MEN MODE J NOT USE 3.
user management TO REMOVE ALL EVENTS If the event memory is full or you want to change the number of IDs, you can use this menu to clear the event memory. 1. Press the F8 SETUP MENU button. 2. Use the buttons press ENT . 4 3. Press the button 1 and 6 to move to the EVENT CLEAR item and 2.EVENT CLEAR 1:YES, 0:NO to remove all events. • To cancel the work, press the button 0. DELETE ALL EVENT WAIT… J To reserve the events, upload them to the host PC before deletion.
I/O time setup EXIT BUTTON OUTPUT 1. Press the F5 SETUP MENU button. 4 and 6 to move to the EXIT BUTTON item and 1.EXIT BUTTON DR AR T1 T2 BZ 03 00 00 00 00 3. You can make input when the prompt blinks. • Use the keypad to enter the time for each output operation and press DR : Door relay output AR : Alarm relay output T1 : TTL #1 output T2 : TTL #2 output BZ : Buzzer output M ENT . 1.EXIT BUTTON DR AR T1 T2 BZ _0 00 00 00 00 The output time differs, depending on the time unit.
I/O time setup AUXILIARY INPUT #1 SETUP 1. Press the F5 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the AUX INPUT #1 item and 3.AUX INPUT#1 DR AR T1 T2 BZ 00 00 00 00 00 3. You can make input when the prompt blinks. • Use the keypad to enter the time for each output operation and press DR : Door relay output AR : Alarm relay output T1 : TTL #1 output T2 : TTL #2 output BZ : Buzzer output M ENT . 3.
TAMPER ALARM OUTPUT SETUP You can set the signal that you want to output if the device is dismantled forcibly. 1. Press the F5 SETUP MENU button. 4 and 6 5.TAMPER ALARM to move to the TAMPER ALARM item and DR AR T1 T2 BZ 00 99 99 99 99 3. You can make input when the prompt blinks. • Use the keypad to enter the time for each output operation and press DR : Door relay output AR : Alarm relay output T1 : TTL #1 output T2 : TTL #2 output BZ : Buzzer output M ENT . 5.
I/O time setup DURESS MODE OUTPUT SETUP You can specify the output time for Duress mode. 1. Press the F5 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the DURESS ALARM item and 7.DURESS ALARM DR AR T1 T2 BZ 00 00 00 00 00 3. You can make input when the prompt blinks. • Use the keypad to enter the time for each output operation and press DR : Door relay output AR : Alarm relay output T1 : TTL #1 output T2 : TTL #2 output BZ : Buzzer output M ENT . 7.
DOOR OPEN TIMEOUT SETUP You can set the alarm to sound if the door stays open after a specific wait time from when it opens. 1. Press the F5 SETUP MENU button. 4 and 6 to move to the DOOR TIME OUT item and DR AR T1 T2 BZ 00 99 00 00 00 3. You can make input when the prompt blinks. • Use the keypad to enter the time for each output operation and press . DR : Door relay output AR : Alarm relay output T1 : TTL #1 output T2 : TTL #2 output BZ : Buzzer output M 9.DOOR TIME OUT ENT 9.
I/O time setup Output Setup for Level 2 IDs Accessing READER #1 1. Press the F6 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the RD1 ID OK LV2 item and • The operation time for each output is the same as in “Output Setup for Level 1 IDs Accessing READER #1” above. (see page 48) 2.RD1 ID OK LV2 DR AR T1 T2 BZ 05 00 00 00 00 Output Setup for Level 3 IDs Accessing READER #1 1. Press the F6 SETUP MENU button. 2. Use the buttons press ENT .
READER #1 ERROR OUTPUT SETUP READER #1 ID Error Output Setup 1. Press the F6 SETUP MENU button. 4 and 6 to move to the RD1 ID ERROR item and 5.RD1 ID ERROR 3. You can make input when the prompt blinks. DR AR T1 T2 BZ 00 03 00 00 00 • If you enter ‘00’, no output setting is configured. • Use the keypad to enter the time for each output operation and press DR : Door relay output AR : Alarm relay output T1 : TTL #1 output T2 : TTL #2 output BZ : Buzzer output M ENT . 5.
I/O time setup OUTPUT SETUP FOR LEVEL IDS ACCESSING READER #2 Output Setup for the event of Level 1 IDs accessing the READER #2 1. Press the F6 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the RD2 ID OK LV1 item and 8.RD2 ID OK LV1 DR AR T1 T2 BZ 03 00 00 00 00 3. You can make input when the prompt blinks. • If you enter ‘00’, no output setting is configured.
Output Setup for Level 4 IDs Accessing READER #2 1. Press the F6 SETUP MENU button. 4 and 6 to move to the RD2 ID OK LV4 item and 11.RD2 ID OK LV4 • The operation time for each output is the same as in “Output Setup for Level 1 IDs Accessing READER #2” above. (see page 51) DR AR T1 T2 BZ 05 00 00 00 00 READER #2 ERROR OUTPUT SETUP READER #2 ID Error Output Setup 1. Press the F6 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the RD2 ID ERROR item and 12.
I/O time setup READER #2 Time Schedule Error Output Setup 1. Press the F6 SETUP MENU button. 2. Use the buttons press ENT . 4 and 6 to move to the RD2 T/S ERROR item and • The operation time for each output is the same as in “READER #2 ID Error Output Setup” above. (see page 52) M 13.RD2 T/S ERROR DR AR T1 T2 BZ 00 03 00 00 00 Time schedule must be configured before. (See Page 55 for “Time Schedule Setup”.) READER #2 Antipassback Error Output Setup 1. Press the F6 SETUP MENU button. 2.
advanced setup TIME UNIT SETUP You can use this menu to specify the time unit. 1. Press the F2 SETUP MENU button. 4 and 3. Use the buttons 4 and 6 to move to the TIME UNIT item and press 3.TIME UNIT J UNIT: 1SEC 6 to specify the time unit and press ENT . • UNIT: 1SEC : The output time is calculated by the second in the I/O setup. UNIT: 0.1SEC : The output time is calculated by the 1/10 second (100ms) in the I/O setup. M 3.TIME UNIT J UNIT: 0.1SEC The default is set to “UNIT: 1SEC”.
advanced setup ANTIPASSBACK MODE Antipassback mode is used to prevent an identical user from entering or exiting the door twice or more consecutively. This mode is available only with an Exit reader dedicated to detecting exits, which is not available in a system that is solely using the Exit button to exit the door. 1. Press the F2 SETUP MENU button. 2. Use the buttons ENT . 4 and 6 to move to the APB MODE item and press 3. Use the buttons 4 and 6 to select a desired mode and press 5.
4. Use the numeric buttons to enter start or end time in 8 digits. 1.TIME SCHEDULE T/S CODE: 01 HOL INTERVAL: 1 00:00 – 00:00 • If an entry is invalid, the “INVALID NUMBER” message will appear. 5. Repeat steps 3 through 4 above to set other time schedules. ESC ADVANCED SETUP 6. Upon completion of all time schedules, press to exit from the menu. HOLIDAY SETUP This feature allows you to set holidays of your choice. Each of 10 Holiday Codes can have up to 100 programmable holidays.
advanced setup HOLIDAY CODE SETUP The Holiday Code setting allows you to link a Holiday Schedule to a Time Schedule.. A Time Schedule has 5 Time Intervals for holidays and the Time Intervals are applied only to the dates of this Holiday Schedule. The Holiday Code ‘00’ means no holiday codes are applied to the Time Schedule. Use the buttons 4 and 6 to scroll up and down from the T/S Code 01 to 10. And, press Holiday Schedule Code. You can also press ENT to store the Holiday Index to the memory. 1.
READER MODE TIME SCHEDULE READER #1 MODE TIME SCHEDULE For example, suppose you want to access the door by only presenting a card from 09:00 to 17:00 and use the Fingerprint Verification method for the rest of the time. And, you can do so by setting [READER1 MODE SETTING] to ID+F/P Mode which will be general operation mode, and program a T/S Code “01” so that it can include a time period between 09:00 and 17:00 for card access.
advanced setup VOICE MESSAGE TIME SCHEDULE The Voice Message Time Schedule function allows you to apply time schedules to the voice message output and mute them at other times. To apply a time schedule code, enter the time schedule code you want. Within the time range assigned by the time schedule, voice messages will be played while at other times, they will not be played. Using this feature, for example, you can configure the unit to play voice messages in the daytime and mute them at night. 1.
INPUT TIME SCHEDULE SETUP You can assign a Time Schedule Code to each input to activate the input only during that period. The default Time Schedule Code for every input is “00”, which means no Time Schedule is applied to them. Changing these settings can be very useful when you want to activate PIR sensor during a certain period of time. F5 SETUP MENU button. 2. Use the buttons 4 and 6 to move to INPUT T/S and press 3. Use the numeric buttons to enter 2-digit code and press ENT ENT . 11.
additional features EVENT MEMORY SETUP 1. Press the F2 SETUP MENU button. 2. Use the buttons ENT . 4 and 6 to move to EVENT MEMORY and press 3. Use the buttons ENT . 4 and 6 to select either USE or NOT USE and press 1.EVENT MEMORY NOT USE • USE : When the event memory is full, it gives out an error message and maintains all events stored in the memory. NOT USE : Even when the event memory is full, it does not give out an error message.
WIEGAND OUTPUT SETUP 1. Press the F2 SETUP MENU button. 4 and 6 to move to the WIEGAND OUTPUT item 3. Use the buttons ENT . 4 and 6 to select either USE or NOT USE and press • USE : It sends 26 bit Wiegand Output (34 bit for SSA-S30X1 series) through two TTL output ports (TTL OUT #1, TTL OUT #2), which can be used as a reader in connection with other controller. NOT USE : This product cannot be used as a reader. 7. WIEGAND OUTPUT NOT USE 7. WIEGAND OUTPUT J NOT USE 7.
additional features ONE TIME READ If the menu is set to “USE”, the card authentication will not take place for the next 30 seconds after an instance of authenticating a registered card. 1. Press the F3 SETUP MENU button. 2. Use the buttons ENT . 4 and 6 to move to ONE TIME READ and press 3. Use the buttons ENT . 4 and 6 to select either USE or NOT USE and press • USE : The card authentication will not take place for 30 seconds after an instance of authenticating a registered card.
INPUT TEST This feature allows you to test settings for each input. 1. Press the F9 SETUP MENU button. 4 and 6 to move to the INPUT TEST item and press 2.INPUT TEST EX DC I1 I2 TP 2 2 2 2 0 3. The corresponding value changes upon input. • 0 : It indicates that the input port is open circuit. 1 : It indicates that the input port is short circuited at the earth-grounding level. 2.INPUT TEST 2 : It indicates that the corresponding port is not connected.
additional features LCD TEST This feature allows you to test the LCD status. The SAMSUNG logo will appear rolling up and down. At this time you can check any abnormality in the LCD. 1. Press the F9 SETUP MENU button. 2. Use the buttons ENT . 4 and 6 to move to the LCD TEST item and press 4.LCD TEST • Check the SAMSUNG logo. 3. The last date the firmware is amended and the version information is displayed. LAST UPDATE v0.50_090803 PRESS ANY KEY KEYPAD TEST 1. Press the F9 SETUP MENU button. 2.
READER TEST This function allows you to test the internal (READER #1) and the external readers (READER #2). 1. Press the F9 SETUP MENU button. 4 and 6 to move to the READER TEST item and 6.READER TEST SCANNING… 3. Place your card close to the reader. When the card is read successfully, the reader number with the 8-digit card number will be displayed on the screen. 4. Press ESC 6.READER TEST to move to the parent menu. READER #1 25500363 6.READER TEST MEMORY TEST 1.
additional features COMMUNICATION TEST Before executing this test, remember to connect the RS232 TX wire (Black wire with White stripe) and the RS232 RX wire (Red wire with White stripe) together. This is to test on the built-in communication chip, not on the communication with the computer. 1. Press the F9 SETUP MENU button. 2. Use the buttons press ENT . 4 6 and to move to the COMM TEST item and 8.COMM TEST • TX DATA : Transmit Data RX DATA : Receive Data 3. Press ENT to start the test. 4.
INPUT TYPE SETUP Either one of NO(00) or NC(01) is available for the input type. The default setting is ‘00(Normal Open)’. 1. Press the F5 SETUP MENU button. 4 and 6 to move to the INPUT TYPE item and press 3. You can make input when the prompt blinks. • Use the numeric buttons to enter ‘00’ or ‘01’ for operation type for each input and press ENT .
other information MENU STRUCTURE Menu Structure of the [F1] button You can set Language, Date/Time and READER modes.
Menu Structure of the [F3] button You can set Voice Volume, Arm/Disarm, Two Men Operation, One Time Read, Number of Users, and Name Display. VOICE VOLUME 0 (MUTE) ~ 4 (MAXIMUM) OTHER INFORMATION F3 button ARM/DISARM TWO MEN MODE ONE TIME READ MAX USER SETUP NAME DISPLAY NOT USE USE NOT USE USE 10,000 20,000 NOT USE USE Menu Structure of the [F4] button You can set Time Schedule, Holiday, Holiday Code, READER #1 and #2 Mode Time Schedule, and Voice Message Time Schedule.
other information Menu Structure of the [F5] button You can set Exit Key Output, Door Contact Sensor, Aux Input #1 and #2, Tamper Alarm Output, Cut Off Output, Duress Alarm Output, Arm/Disarm Output, Door Open timeout Output, Input/Output Time Schedule, Input Cut Off Check, and Input Type.
Menu Structure of the [F6] button You can set Output for Accessible levels for READER #1 and #2 ID, READER #1 and #2 ID Error Output, READER #1 and #2 Time Schedule Error Output, READER #1 and #2 Antipassback Error Output.
other information Menu Structure of the [F7] button You can register or delete IDs and register the master ID. You can also view the ID list, ID count and event count. F7 button REGISTRATION CARD KEY ID DELETE ID LIST MASTER ID REG REG. ID COUNT EVENT COUNT Menu Structure of the [F8] button You can initialize the master mode and delete the entire events, IDs, Master ID and Time Schedules. F8 button SYSTEM INIT.
Menu Structure of the [F9] button You can check the system version. You can also test the input, output, LCD, keypad, reader, memory and communication status. F9 button FIRMWARE VER OTHER INFORMATION INPUT TEST OUTPUT TEST LCD TEST KEYPAD TEST READER TEST MEMORY TEST COMM TEST [Menu Structure of the [F10] button You can set the Dual Fingerprint Mode and ID Modes, and check the number of registered fingerprints and the fingerprint module version.
other information DEFAULT SETTINGS Output Settings for Input Sources Output Door Relay (DR) Alarm Relay (AR) TTL#1 (T1) TTL#2 (T2) Buzzer (BZ) [1] Exit Button 03 00 00 00 00 [2] Door Contact 00 99 00 00 00 [3] AUX Input #1 00 00 00 00 00 [4] AUX Input #2 00 00 00 00 00 [5] TAMPER Alarm 00 99 99 99 99 [6] Cut Off Alarm 00 00 00 00 00 [7] DURESS ALARM 00 00 00 00 00 Input [8] ARM/DISARM OUT 00 00 00 00 00 [9] Door Open Timeout 00 99 00 00 00 [10] Ou
Output Setting for Authentication Output Alarm Relay (AR) TTL#1 (T1) TTL#2 (T2) Buzzer (BZ) [1] Reader#1 ID OK LV1 03 00 00 00 00 [2] Reader#1 ID OK LV2 05 00 00 00 00 [3] Reader#1 ID OK LV3 05 00 00 00 00 [4] Reader#1 ID OK LV4 05 00 00 00 00 [5] Reader#1 ID Error 00 03 00 00 00 [6] Reader#1 T/S Error 00 03 00 00 00 [7] Reader#1 APB Error 00 03 00 00 00 [8] Reader#2 ID OK LV1 03 00 00 00 00 [9] Reader#2 ID OK LV2 05 00 00 00 00 [10] Reader#2 ID OK
troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. PROBLEM A valid card that had been in use became unregistered after batch-downloading IDs from a PC. SOLUTION 1) 2) 3) 4) I entered the Master ID “00000000” but I still cannot enter the Setup Mode (“0000000000” for SSA-S30X1) 1) 2) 3) The card ID might be registered only to the controller and not to the PC.
PROBLEM SOLUTION 1) The buzzer keeps beeping. 1) 1) If the unit used to operate properly before, it is likely that there has been an electric shock that damaged the internal memory and data. Please initialize the unit as instructed in the manual. 2) Check if the ID information has been entered correctly during its registration. - Check if the value for RD is set correctly during the ID registration.
product specifications PRODUCT SPECIFICATIONS Item User SSA-S3010 SSA-S3020 SSA-S3040 Total Users 10,000 / 20,000 Users (Selectable) Fingerprint Users 1,000 2,000 4,000 Fingerprint Templates Size 800 Bytes for 2 fingerprint Templates Event Buffer 20,000 / 10,000 Event Buffers (Selectable) Power / Current SSA-S3011 SSA-S3021 SSA-S3041 1,000 2,000 4,000 DC 12V 540mA DC 12V 560mA Reader Port 1ea: 26bit Wiegand, 8bit Burst for PIN for Anti-Pass-Back Reading Time (Card) 30ms Verificatio
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.