SSA-S1000 Standalone RFID Access Controller user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
5. Keep out of direct sunlight and heat radiation sources. It may cause fire. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.
contents PRODUCT INTRODUCTION 5 INSTALLATION AND EXTERNAL CONNECTION 9 SYSTEM INITIALIZATION & BASIC OPERATIONS 12 PRODUCT SPECIFICATIONS 15 5 6 7 8 8 Feature What’s included At a Glance Cable Color Scheme Cable Selection 9 9 10 Installation Bypass Diode Connection I/O Connection 12 12 13 13 Initializing the system by short-circuiting Basic Operations To register /delete Master ID To register/delete ID card 15 Product Specifications
product introduction FEATURE ◆ 125 kHz Proximity Access Controller ◆ Up to 512 users including one Master ID can be registered ◆ Standalone (no application S/W required) ◆ Direct Control of the Door Lock ◆ Can select a lock device type from Power Fail Safe and Power Fail Secure ◆ Epoxy Molding ◆ Weatherproof English5 PRODUCT INTRODUCTION This product is designed for use with one-door access control for security applications.
product introduction WHAT’S INCLUDED Check if the following items are included in the product package. tGj Main Module Bezel Master Card (x1) Keytag (x5) xGn 3.5 x 40mm Screws (x2) 3.
AT A GLANCE Front/Rear PRODUCT INTRODUCTION 3 4 5 1 LED Displays the system operation status using red and green indicators. 2 Fixing Hole Fixing hole for wall-mounting. 3 Connection Cable Used to connect to the power or I/O cable. 4 Program Port Port used to upgrade the firmware. 5 Buzzer Piezo buzzer.
product introduction CABLE COLOR SCHEME Item Cable Color Signal Line Description Red DC+12V Black GND Yellow AUX INPUT#1 Blue Door Contact Sensor Green Exit Button Exit Button Connection Port Purple Alarm Out Alarm Device Connection Port White Door Lock Out +12V supplied Power Input Earth-Grounding for Power Select a Lock Type Door Sensor Connection Port Output Door Lock device connection port Gray Orange Not used Brown CABLE SELECTION Item 1 2 Power (DC +12V) Belden #9409, 18
installation and external connection INSTALLATION INSTALLATION AND EXTERNAL CONNECTION 10 6-32 hole 44.4 6-32 or M3 Screws 1/2” hole 40.6 6-32 hole Reader Module 8.5 - On a doorframe or the wall 1. Drill a 1/2-inch (12.7 mm) hole onto the center of the doorframe or the wall where SSA-S1000 is installed, which makes room for the cable of the reader module. 2. Drill two 0.3-inch (7.62 mm) holes: one on the point of 0.39 inch (10 mm) horizontally to the right, 1.74 inch (44.
installation and external connection I/O CONNECTION Input Connection DOOR CONTACT (blue) Door Contact Sensor EXIT BUTTON (green) Exit Button PUSH DC +12V GND (black) GND DC +12V (red) DC 12V(+) POWER - To connect the power supply unit 1. Connect the DC+12V to the red line. 2. Connect GND to the black line. - To connect the Door Contact Sensor 1. Connect the COM port of the sensor to the blue line. 2. Connect the NO port of the sensor with the GND line. - To connect the Exit Button 1.
Output Connection DOOR LOCK OUT (white) Door Lock INSTALLATION AND EXTERNAL CONNECTION ALARM OUT (purple) Alarm Device Lock Type Select (yellow) Cathode Anode 1N4004 ~ 1N4007 or equiv. DC +12V GND DC 12V(+) POWER - To connect the power supply unit 1. Connect the DC+12V to the red line. 2. Connect GND to the black line. - To connect the door lock device 1. Connect the plus(+) line of the lock device to DC+12V. 2. Connect the minus(-) line of the lock device to the white line.
system initialization & basic operations INITIALIZING THE SYSTEM BY SHORT-CIRCUITING 1. Turn off the product and short-circuit three lines: white line of the door lock device, green line of the Exit button, and yellow line of the lock type. Short-Circuit White 2. When you turn the product back on, all of the LED indicators turn red or green, repeat turning on/off twice before being completely turned off. Door Lock Green Exit Button Yellow Lock Type 3.
TO REGISTER /DELETE MASTER ID 1. First turn off the product, and short-circuit two lines: purple line of Alarm Out and blue line of the Door Contact Sensor. SSA-S1000 Cable Yellow Green Short-Circuit 3. Upon deletion of the Master Card, you will hear a beep once and all of the LED indicators toggle between green and red twice before turning off; in this condition, they turn red from bottom up in sequence. Purple White Red DC12V 4. When the deletion is completed, turn off the product.
troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. PROBLEM SOLUTION The user card is not deleted. 1) The Exit button does not work at all. 1) 14_ troubleshooting Check if the product works properly. - If the product works properly and you have the Master Card c Read the Master Card. d Read the card to delete.
product specifications PRODUCT SPECIFICATIONS Item SSA-S1000 512 Users Power / Current DC 12V / Max.110mA Reading Time (Card) 30ms Door Open Time 5sec. (Fixed) Input Port 3ea: Exit Button, Door Sensor, Lock Type Select [Power fail Safe / Power Fail Secure] Output Port 2ea : TR Output / DC 12V. Rating Max. 300mA Alarm Output, DC 12V. Rating Max.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.