- S EC - S WC WB TMPL- 002 Ver. 1.0 2005- 05- 27 DMS User Manual Copyright © 1999-2002 Samsung Electronics Co., Ltd. Copyright notice This document is Copyright © Samsung Electronics, Co. – all rights reserved.
DMS User Manual Version 1.0 Table of Contents 1. GENERAL DESCRIPTION ..........................................................................................................3 1.1. DMS System Feature........................................................................................................3 1.1.1. System Establishment Environment .........................................................................3 1.2. Introduction of DMS Function .......................................................
1. General Description 1.1. DMS System Feature 1.1.1. System Establishment Environment 1.2. Introduction of DMS Function 1.2.1.
DMS User Manual Version 1.0 12) Information inquiry / settion of the demand controller 1.2.2. Console Function 13) Network information inquiry / setting 14) Information inquiry / setting of the service server 15) Inquiry / setting of the data 16) Inquiry of tracking information / Execution of tracking 17) Setting of DMS cryptograph 18) Master DMS inquiry / setting 19) Inquiry / initialize of the setting information priority order 20) DMS rebooting 1.2.3.
2. DMS Installation 2.1. Prapration of the installation 2.1.1. Confirmation of the package DMS Case(UM 32009L) 1SET / pannel 2EA DMS Main Board, Sub Board, Cable Serial Cable 1EA Power Cable 1EA Ethernet Cable 1EA 2.1.2. Check list before the installation C onfirmation of the C AUR’ s operation DMS c ontrol the DVM S ystem Air c onditioner through c ontrolling the C AUR.
2.2. Installation 2.2.1.
DMS User Manual Version 1.0 Item Contents Power Reset DI DO Ethernet Supply the power. Used in system reset. Connected to switch to create signal. Control the on/off of the relay. Connected to i-MFC, S-Net and Service Server though LAN cable Connected to CAUR, outdoor equipment and indoor equipment through coaxial cable. And then DMS collect the data and control through this. Used Version Upgrade and checking the defect. Display the system status.
DMS User Manual Version 1.0 2.2.2. DMS Connection Power R S-485 E thernet Power : Connect to AC Power through power cable. DI : Connect to external switch. Be careful of +, - sign. DO : Connect to external relay. Becareful of +, - sign. Ethernet : Connect to LAN Cable. RS-485 : Connect to CAUR. Be careful of C1, C2 sign. DI DO 1) 2) 3) 4) 5) Caur Back side Software Center, Samsung Electronics Co., Ltd.
DMS User Manual Version 1.0 2.3. Check list after installation Check the LED status displayed on the case after all connection is cleared. LED name Power CPU Alive nLinked nLanLED Tx Data Rx Data DI 1 / 2 DO 1 DO 2 Contents If the power is supplied, this LED is turn on. Initial state is off. If the CPU is alive, this LED is twinkling Initial state is off. If LAN cable is connected, this LED is turn on. Initial state is off.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.