Instruction Manual
Dimensions: flow meters with electronic registration
Note: Dimensions shown are not for construction use. Consult factory when certified
engineering prints are required.
Construction and application classes
LC series M and MA PD meters are suitable for
metering a broad range of products as listed below.
The appropriate meter class can be used to specify a
desired meter by using the table on the next page of
this publication.
Class Description
Bearing
Material
1 Refined petroleum products Ni-Resist
2 Aviation and jet fuel Ni-Resist
3
Variety of product includes:
liquid sugars, sweeteners,
syrups, vegetable oils
Ni-Resist
4
Treated waters and solvents
where no red metals are
allowed
Carbon
8
Acid pH liquids includes: nitric,
phosphoric, glacial acetic acids,
citric juices, vinegar
Carbon
14 Crude oil Ni-Resist
16 General solvents Carbon
30 Herbicides Carbon
Model
Flange
size
Max nom.
Flow rate
Working
pressure
Net
weight
Dimensions
A B C D E F
M-15
3” or 3” in,
2” out
1000 l/min
(264 GPM)
10,5 bar
(150 PSI)
16,8 kg
(37 lbs)
in 17 7.5 5 7.7 .69 3.8
mm 432 191 127 195 17 95
Dimensions
G H I J K L M N O
in 5.5 12 10.8 16.1 1.3 5 11.1 5.1 6.5
mm 140 291 273 410 32 127 238 129 165