Specifications

IMPORTANT SAFETY INSTRUCTIONS
Please read before using your power supply.
CAUTION!
ALL ELECTRICAL INSTALLATIONS MUST
MEET LOCAL AND NATIONAL WIRING
CODES AND SHOULD BE PERFORMED BY A
QUALIFIED ELECTRICIAN.
COOLING:
If the module is installed in an enclosed case, forced air
cooling should be provided.
AC INPUT:
The power supply module should be operated from 120V
AC/60 Hz source with proper earth ground connection.
120V, 60 Hz AC input is fed through quick disconnects
marked “L” & “N”. The pads under holes S1,S3 & S4 (Fig.
1 on page 4), should be connected to earth ground. Color
code for AC input wires is:
NEMA INTERNATIONAL
QUICK DISCONNECT “L” BLACK BROWN
QUICK DISCONNECT “N” WHITE BLUE
PADS UNDER HOLES S1,S3,S4 GREEN GREEN / YELLOW STRIPE
1.
14.
SPECIFICATIONS
INPUT VOLTAGE RANGE
105 to 125 V AC, 60Hz
OUTPUT VOLTAGE
(Pre-set) 28V DC
Adjustment 26.8 to 28.5V DC
OUTPUT VOLTAGE REGULATION
1%
OUTPUT CURRENT
CONTINUOUS 10A
SURGE 11.5A
OUTPUT CURRENT LIMIT
12A
OUTPUT RIPPLE
LESS THAN 150mV PEAK TO
PEAK
OUTPUT NOISE
LESS THAN 2V PEAK TO PEAK
COOLING
THROUGH HEAT SINK MOUNTED
ON THE PCB. REQURES FORCED
AIR COOLING.
OPERATING TEMPERATURE
0 TO 40
O
C
PARALLEL OPERATION
YES, ACTIVE CURRENT SHARING
PROTECTIONS
SHORT CIRCUIT YES
CURRENT LIMIT YES
INPUT SURGE SUPRESSION YES
FUSE 250V, 4A, SLOW-BLOW
DIMENSIONS
7.2” X 3.4” X 2.5”
WEIGHT, LBS
1.6