Technical data
8
The ExCam niteZoom is a zoom camera certified according to Directive 94/9/EG (ATEX). With its 1/3‘‘
Super HAD CCD II sensor and the IR cut filter it is one of the most light sensitive cameras of its
class. As a result the ExCam niteZoom delivers high resolution pictures even at an illumination level
of only 0.0004 lx. Despite its compact dimensions, it has a 10x motorized zoom lens, allowing it to be
optimally adapted to a specific angle and lighting situation.
ExCam niteZoom
in a stainless steel housing
ExCam niteZoom
Product / Model Description
ExCam niteZoom
T03-VA-B-005-X-N
Camera with motor zoom in a stainless steel housing in accordance with
Directive 94/9/EC (ATEX).
Minimal illumination: 1/4 s, 1/3 s mode & ICR on: 0.0004 lx
Interface: VISCA@RS422
Explosion protection (gas): Ex II 2G Ex d IIB T6 Gb
Explosion protection (dust): Ex II 2D Ex t IIIC T80° C Db IP67
Protection level: IP 67 (IEC / EN 60529)
Ambient temperature limit: 0° C < T
amb
< +50° C
See data sheet for technical data - www.samcon.eu
Product group: A, tariff number: 8525 8019
ExCam niteZoom
T03-VA-C-XXX-X-X
Option IIC (surcharge):
Certified after IIC for atmospheres containing hydrogen, carbon disulphide and
acetylene. Includes cable gland with integrated pressure stop. In accordance with
DIN EN 60079-14.
Explosion protection (gas): Ex II 2G Ex d IIC T6 Gb
ExCam niteZoom
T03-VA-X-XXX-X-L
Option housing heating (surcharge):
Equipped with a self regulating heater for housing.
Ambient temperature limit: -20° C < T
amb
< +50° C
ExCam niteZoom „K2“
T03-VA-X-XXX-X-X
Option „K2“ (surcharge):
Option with 90° angle flange.
The cable gland is laterally introduced into the flange.
ExCam niteZoom „pin free“
T03-VA-X-XXX-X-X
Option „pin free“ (surcharge):
Version with an even VA housing without pin attachment.
Suitable for flange fixation as well as hose clips.
ExCam niteZoom „more Power“
T08-VA1.2.K1.BOR-XXX-X-X
You need an ExCam
®
niteZoom with IECEx certification?
With an approval for mining or with extended temperature range?
We are currently working on an upgrade.
Please contact us!
Group I (Mining) ATEX
Category Ma Mb
Application
Group II (Gas & Dust) ATEX
Zone 0 1 2 21 22
Application