Technical data
11
ExCam IP1355
in Stainless Steel
ExCam IP1355
The ExCam IP1355 is a network camera, approved according to Directive 94/9/EG (ATEX) and IECEx.
The video streams and control signals are therefore directly available within the network.
Due to Power over Ethernet (PoE) kit is possible to have only one cable for transmitting data as well
as power! The ExCam IP1355 delivers several different video streams at the same time and supports
MJPEG and H.264 in HD resolution of 1920x1080 pixels.
Product / Model Description
ExCam IP1355
T08-VA2.2.K1.BOR-B-005-X-N
Network camera in a stainless steel housing in accordance with
Directive 94/9/EC (ATEX) and IECEx
PoE, IEEE 802.3af Class 3 (7,1 W)
Minimal illumination: Color: 0.2 lux, black/white: 0.04 lux, F1,2
Horizontal angle: 109° - 39° (HD, 16/9)
Video compression: H.264 & Motion JPEG
Resolution: 1920 x 1080 (approx. 2 MP) to 160 x 90
Lens mount type: CS Mount
Explosion protection (gas): Ex II 2G Ex d IIB T6 Gb
Explosion protection (dust): Ex II 2D Ex t IIIC T80° C Db IP68
Explosion protection (mining): Ex I M2 Ex d I Mb
Protection level: IP 68 (IEC / EN 60529)
Ambient temperature limit: -10° C < T
amb
< +40° C
See data sheet for technical data - www.samcon.eu
Product group: A, tariff number: 8525 8019
ExCam IP1355
T08-VA2.2.X.BOR-C-XXX-X-X
Option IIC (surcharge):
Certified after IIC for atmospheres containing hydrogen, carbon disulphide and
acetylene. Includes cable gland with integrated pressure stop. In accordance
with DIN EN 60079-14.
Explosion protection (gas): Ex II 2G Ex d IIC T6 Gb
ExCam IP1355
T08-VA2.2.K1.BOR-X-XXX-X-L
Option: Housing heating (surcharge):
Equipped with a self regulating heater for housing suitable for low temperature ranges:
Ambient temperature: -30° C < T
amb
< +40° C
ExCam IP1355
T08-VA2.2.K1.BOR-X-XXX-X-LL
Option: Housing heating for arctic temperatures (surcharge):
Equipped with a self regulating heater for housing suitable for extremely low tempera-
ture ranges:
Ambient temperature: -60° C < T
amb
< +40° C
ExCam IP1355 „K2“
T08-VA2.2.K2.BOR-X-XXX-X-N
Option „K2“ (surcharge):
Option with 90° angle flange.
The cable gland is laterally introduced into the flange.
Group I (Mining) ATEX / IECEx
Category Ma Mb
Application
Group II (Gas & Dust) ATEX / IECEx
Zone 0 1 2 21 22
Application